Description
Introduction
The class E2 standard weight in stainless steel is the essential reference element to guarantee the accuracy of any analytical or precision balance in laboratories, pharmacy, pharmaceutical industry and metrology centres. Being the second most accurate class on the OIML scale (only surpassed by E1), it allows detecting drifts and misalignments in weighing equipment before they compromise the results of the analyses.
At Cahnos we supply it as an individual weight with case, in the nominal value you need and with the option of an ENAC calibration certificate to ensure the official traceability of your process.
Technical explanation
Class E2 weights are manufactured in high-quality stainless steel, with a polished surface, low magnetic susceptibility and excellent corrosion resistance, which minimises moisture absorption and surface contamination that would alter the conventional mass value. Each weight is adjusted within the maximum permissible errors established by OIML R111 recommendation, so that the actual mass value is maintained within very strict tolerances across its entire nominal range.
Thanks to its high stability, class E2 is the recommended option for calibrating analytical balances and microbalances, as well as serving as a reference in laboratories that must meet quality requirements such as ISO 9001, ISO 17025, GLP or GMP. The use of gloves, forceps or handling with suitable tools is essential to preserve its traceability, since the grease or heat from hands can significantly modify its mass.
Technical specifications
| Field | Detail |
|---|---|
| Description | Individual class E2 weight, in stainless steel, for analytical balances. |
| Family | Standard weights — Class E2 |
| Typical use | Analytical and precision balances |
| Usual material | Stainless steel |
| Case | Yes |
| Reference standards | OIML R111 |
| Class | Description | Available nominal values |
|---|---|---|
| E2 | Special precision | 1 mg – 5 kg (references available up to 10 kg) |
Maximum permissible tolerances class E2 (OIML R111)
| Nominal value | Maximum permissible error (±) |
|---|---|
| 1 mg | ± 0.020 mg |
| 2 mg | ± 0.020 mg |
| 5 mg | ± 0.020 mg |
| 10 mg | ± 0.025 mg |
| 20 mg | ± 0.03 mg |
| 50 mg | ± 0.04 mg |
| 100 mg | ± 0.05 mg |
| 200 mg | ± 0.06 mg |
| 500 mg | ± 0.08 mg |
| 1 g | ± 0.10 mg |
| 2 g | ± 0.12 mg |
| 5 g | ± 0.16 mg |
| 10 g | ± 0.20 mg |
| 20 g | ± 0.25 mg |
| 50 g | ± 0.30 mg |
| 100 g | ± 0.50 mg |
| 200 g | ± 1.0 mg |
| 500 g | ± 2.5 mg |
| 1 kg | ± 5.0 mg |
| 2 kg | ± 10 mg |
| 5 kg | ± 25 mg |
| 10 kg | ± 50 mg |
References and ordering information
| Capacity | Case | Description |
|---|---|---|
| 1 g | Yes | Individual weight |
| 2 g | Yes | Individual weight |
| 5 g | Yes | Individual weight |
| 10 g | Yes | Individual weight |
| 20 g | Yes | Individual weight |
| 50 g | Yes | Individual weight |
| 100 g | Yes | Individual weight |
| 200 g | Yes | Individual weight |
| 500 g | Yes | Individual weight |
| 1 kg | Yes | Individual weight |
| 2 kg | Yes | Individual weight |
| 5 kg | Yes | Individual weight |
| 10 kg | Yes | Individual weight |
Regulations and documentation
| Aspect | Detail |
|---|---|
| Reference standards | OIML R111 |
| Optional documentation | ENAC calibration certificate |
Equivalences and cross-references
The OIML R111 class scale orders standard weights from highest to lowest precision: E1, E2, F1, F2, M1, M1-2, M2, M2-3 and M3. The class E2 offers tolerances approximately five times stricter than class F1 and ten times stricter than M1, which makes it the natural choice for analytical balances with a reading of 0.01 mg to 0.1 mg. In the Cahnos catalogue you can cross-reference this item with others in the same family as needed: the class F1 weight in stainless steel (PESA-F1INOX) for general-purpose precision balances, or the chrome-plated brass versions (PESA-F1LATON, PESA-M1LATON, PESA-M2LATON) and the high-capacity M1 weights in cast iron (PESA-M1HIERRO) for verifying industrial scales. If your requirement is maximum metrological rigour, class E2 is the most commercially balanced option between cost and accuracy, comparable to the special precision series of the main European manufacturers of standard masses.
Selection tips and variants
- Select the nominal value according to the usual calibration points of your balance: it is recommended to verify at least with weights close to 10%, 50% and 100% of the equipment’s capacity.
- An analytical balance with a reading of 0.1 mg is correctly calibrated with class E2 weights, while for readings of 0.01 mg class E1 may be required (check availability on request).
- If your process requires audits or official traceability to national standards, request the weight with ENAC calibration certificate: each piece is issued with its conventional mass value, expanded uncertainty (k=2) and corrections.
- Always handle the weight with gloves, forceps or a technical cloth, avoid hand contact and keep it in its case when not in use to preserve its class.
- For complete control, combine this weight with a set of standard masses of the same class or with the analytical balance suitable for your workload.



Reviews
There are no reviews yet.