We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Portable X-ray Generator meX+ 40 – 100 kV / 35 mA · 2.4 kW · High Frequency – medical ECONET (MEC15.30-1240)

Price on request

The portable X-ray generator meX+ 40 from medical ECONET (ref. 15.30-1240) combines a 100 kV / 35 mA tube with high-frequency technology and a maximum power of 2.4 kW at 80 kV, ensuring constant emission without fluctuations for sharp and reproducible images. Its low weight of 12.8 kg and its practical manual switch control make it the ideal solution for mobile veterinary radiology, emergencies and on-site radiography consultations. It incorporates a focus-film measuring tape, 8 memory positions for kV and mAs, reversible LED display, collimator with LED light and dual distance laser for precise framing of the radiation field. Product sold on quotation: consult our technical-commercial team.

International shipping. Import duties and taxes are payable by the recipient.

Reference
MEC15.30-1240

You will also find it in

Description

1. Introduction

The meX+ 40 from medical ECONET is a high-frequency portable X-ray generator manufactured in Germany by medical ECONET GmbH, designed for professionals who need diagnostic-quality images with total mobility. Its compact design and weight of just 12.8 kg make it perfect for veterinary clinics, mobile radiography services, emergencies and visits to farms or practices. With a 100 kV / 35 mA tube and maximum power of 2.4 kW, it offers an excellent balance between performance, portability and ease of use.

2. Technical explanation of the equipment

The meX+ 40 uses high-frequency generator technology that ensures constant X-ray emission with no performance fluctuations, ensuring the reproducibility of each examination and reducing repeats. It incorporates a measuring tape for measuring the focus-film distance, which facilitates correct positioning of the cassette or detector, and 8 memory positions for preselecting kV and mAs, so that the technician can save their most common protocols and minimise the risk of exposure errors. The 7-segment LED display is reversible for comfortable reading in any orientation, and the remote control via manual switch (hand switch) allows the collimator light and laser to be activated remotely. The collimator with LED light and the dual distance laser facilitate precise framing of the radiation field, reducing unnecessary doses.

3. Technical Specifications

Parameter Value
Brand / Manufacturer medical ECONET GmbH
Manufacturer reference 15.30-1240 / MEC15.30-1240
Generator type High-frequency portable
Tube voltage / current 100 kV / 35 mA
mAs range 0.4 mAs – 100 mAs (25 steps)
Maximum power 2.4 kW at 80 kV
Focal spot 1.2 mm
Collimator lamp LED
Distance laser Integrated dual laser (dual laser)
kV / mAs presets 8 APR (8 memory positions)
Display Reversible 7-segment LED
Distance measurement Focus-film measuring tape
Control Manual switch with light and laser functions
Weight 12.8 kg

Available references

Reference Description
MEC15.30-1240 Portable X-ray generator meX+ 40 – medical ECONET (SKU Cahnos)
15.30-1240 Original manufacturer reference medical ECONET

4. Equivalences and Cross-References

The meX+ 40 belongs to the meX+ series of portable generators from medical ECONET, alongside the meX+20 (ref. 15.30-1211), meX+40BT (ref. 15.30-1243), meX+60 (ref. 15.30-1260) and meX+100 (ref. 15.30-1200 in human and VET versions). They all share the same family and design, but are not interchangeable 1:1 with each other as they differ in kV/mA, power, memory and weight. The meX+ 40BT is the version with integrated battery of the meX+ 40: it shares the 100 kV / 35 mA tube, power of 2.4 kW at 80 kV and focal spot of 1.2 mm, but expands the memory to 21 positions and adds autonomy of up to 173 exposures per charge. There is no equivalence table validated by the manufacturer against generators from other manufacturers for this model; any market alternative must be compared property by property (kV/mA, power, focal spot, weight and accessories) before considering any substitution. Consult our technical department before using this equipment in tenders or as a direct replacement.

5. Selection tips and variants of interest

Choose the meX+ 40 if you need an intermediate power point (100 kV / 35 mA, 2.4 kW) with a very contained weight of 12.8 kg and simple protocol management via its 8 APR presets. If you work without relying on the mains supply, consider the meX+ 40BT (ref. MEC15.30-1243), the version with integrated battery of this same equipment. If you have a larger budget and require shorter exposure times, the series offers the meX+ 60 (100 kV / 60 mA, 3.2 kW, 14.6 kg); for maximum portable power, the meX+ 100 (110 kV / 100 mA, 5 kW). For work on a stand in veterinary radiology, the generator is compatible with the PXMS-1800 mobile floor stand (ref. MEC11.99-9040), suitable for portable generators from 9 to 20 kg such as this model. It is recommended to complete the system with DR digital detectors from the meX+ range for a fully portable radiography solution. This product is sold on quotation: consult our technical-commercial team at Cahnos for supply conditions and configuration of your project.

Additional information

Manufacturer

medical ECONET GmbH

Manufacturer reference

15.30-1240 / MEC15.30-1240

Generator type

High-frequency portable

Tube voltage/current

100 kV / 35 mA

mAs range

0.4 mAs – 100 mAs (25 steps)

Maximum power

2.4 kW at 80 kV

Focal spot

1.2 mm

Collimator lamp

LED

Distance laser

Integrated dual laser (dual laser)

kV/mAs presets

8 APR (8 memory positions)

Display

Reversible 7-segment LED

Distance measurement

Focus-film measuring tape

Control

Manual switch with light and laser functions

Weight

12.8 kg

Documentation

Reviews

There are no reviews yet.

Be the first to review “Portable X-ray Generator meX+ 40 – 100 kV / 35 mA · 2.4 kW · High Frequency – medical ECONET (MEC15.30-1240)”

Your email address will not be published. Required fields are marked *