Description
1. Introduction
The veterinary radiology table TKF-2 from medical ECONET is the conventional radiology solution designed for veterinary clinics and hospitals that need a robust, ergonomic and versatile examination station. Designed to work with analogue cassettes, computed radiography (CR) systems and digital detectors (DR), this table supports the progressive digitalisation of your centre without forcing you to change equipment. Its floating tabletop in four directions facilitates patient positioning and optimises the daily workflow of the imaging department.
2. Technical explanation of the equipment
The TKF-2 is a fixed radiographic table for veterinary use whose central element is a floating tabletop in 4 directions: the multidirectional movement allows precise centring of the anatomical area of interest under the X-ray beam without having to move the animal, a key advantage in restless patients or repeated examinations. The surface is scratch-resistant, ensuring a long service life even with intensive use. The table is compatible with portable X-ray equipment of various sizes, so it can be integrated with the mobile generator the clinic already has. It also allows the optional incorporation of a removable anti-scatter grid (anti-scatter grid), which reduces scattered radiation and improves image contrast, especially in abdominal and thoracic examinations.
3. Technical Specifications
The verified technical features from the manufacturer for the TKF-2 table (ref. 11.98-9942-11) are detailed below:
| Parameter | Specification |
|---|---|
| Image compatibility | Suitable for analogue cassettes, CR and DR |
| Table top | Floating in 4 directions and scratch-resistant (149 x 64 cm) |
| Anti-scatter grid | Removable (optional) |
| Generator compatibility | Compatible with portable X-ray equipment of various sizes |
| Dimensions | 149 x 86 x 200 cm |
Available references:
| Reference | Description |
|---|---|
| MEC11.98-9942-11 | Veterinary radiology table TKF-2 (this product) |
| 11.98-9942-11 | Equivalent medical ECONET article number |
4. Equivalences and Cross-References
The product is marketed under the manufacturer reference medical ECONET 11.98-9942-11 (SKU Cahnos: MEC11.98-9942-11). No direct 1:1 equivalents with tables from other manufacturers have been identified in reliable sources; before considering any substitution in a tender, it is necessary to compare tabletop dimensions, floating tabletop travel, compatibility with cassettes/DR and accessories. Within the medical ECONET ecosystem (meiVET veterinary range), the following verified accessories compatible with the TKF family are available:
- Removable anti-radiation grid, ref. 11.98-9943A: for reducing scattered radiation in front of the detector.
- Patient fixation forceps, ref. 11.99-9994: set of 4 forceps for the tabletop.
- Dysplasia fixation forceps, ref. 80.99-9956: compatible with TKF tables and the ECOray system.
These references belong to the same manufacturer as the product; please consult our commercial team to confirm availability and compatibility with your configuration.
5. Selection tips and variants of interest
Before choosing your veterinary radiology table, consider the tabletop size (149 x 64 cm), suitable for small and medium-sized animals, and the overall dimensions of the equipment (149 x 86 x 200 cm) to verify that you have sufficient space in the room. Consider incorporating the removable anti-scatter grid (optional) if you perform examinations of areas with greater anatomical thickness or if you work with DR detectors that benefit from reduced scattered radiation. Confirm compatibility with your portable X-ray equipment (height, tube travel and collimation), as the table is designed to integrate with mobile generators of various sizes. If your centre plans progressive digitalisation of the imaging area, the TKF-2 is a safe investment: it works today with analogue cassettes or CR and tomorrow with DR digital detectors without needing to replace the table. This product is marketed on a quotation basis: contact the technical-commercial team at Cahnos to receive a quote tailored to the needs of your veterinary centre.