Double J ureteral stent with multi-loop at both ends, stent only, radiopaque Tecoflex® in blue or white, MEDpro (Ref. DJSBEM)

275,00 €

Double J ureteral stent with multi-loop at both ends in its stent-only version, manufactured in radiopaque Tecoflex® (blue or white) by MEDpro. Designed to ensure ureteral patency in obstructions due to kidney stones, tumour compression or after endourological procedures, with an expected dwell time of up to 30 days. Its double multi-loop anchoring in the renal pelvis and bladder minimises the risk of migration and allows fluoroscopic control during placement. It is supplied in a peelable sterile single-use package, with size and length configurable on request and formal quotation. The efficient and cost-effective solution for urology and nephrostomy services.

International shipping. Import duties and taxes are payable by the recipient.

Reference
DJSBEM
Brand
MEDpro

Description

1. Introduction

We present the double J ureteral stent MEDpro with multi-loop at both ends, in its stent-only version, available in blue or white and manufactured in radiopaque Tecoflex®. It is the reference urinary drainage solution for urology and nephrostomy services that need to keep the ureter patent temporarily, with an expected dwell time of up to 30 days, and that value a reliable product, comfortable for the patient and very cost-competitive.

This reference DJSBEM is the basic configuration of the family: only the stent, without suture, guidewire, clamp or pusher. An efficient choice for hospitals, clinics and healthcare purchasing centres that have their own placement system, with sizes configurable on request and formal quotation.

2. Technical explanation of the equipment and procedure

Ureteral stents are used to ensure the patency of a ureter whose lumen may be compromised, for example, by a kidney stone (urolithiasis), by tumours located near the ureter or in the ureter itself, or after endourological procedures. This method is often used as a temporary measure to prevent damage to a blocked kidney until definitive treatment can be performed to remove the stone or resolve the obstruction.

The multi-loop design at both ends improves stent anchoring in both the renal pelvis and the bladder, minimising the risk of migration. Tecoflex® material is radiopaque, allowing fluoroscopic control during placement and subsequent verification of its position. These stents can also be used after the so-called basket retrieval procedure (ureteroscopy for stone removal), in which case they are left in place for approximately one week to prevent spasms or collapse of the ureter after the trauma of the procedure.

3. Technical Specifications

The main specifications and available options for this family of double J stents with multi-loop at both ends are detailed below, according to the manufacturer’s technical catalogue MEDpro.

3.1 General characteristics

Characteristic Detail
Family Double J stent with multi-loop at both ends (DJSBEM)
Reference / SKU DJSBEM
Configuration Stent only (without accessories)
Material Radiopaque Tecoflex® (standard polyurethane), fully radiopaque
Colour Blue or white
End type Multiple loop at both ends (anchoring in renal pelvis and bladder)
Indwelling time Standard stent, up to 30 days
Radiopacity Yes, allows fluoroscopic placement control
Sterility / use Sterile peel-open packaging, single-use
Presentation Individual sterile package; box (see units)

3.2 Available order sizes (configurable on request)

Parameter Available values
Size (x0.1 Char) 30 · 35 · 38 · 40 · 45 · 47 · 48 · 50 · 55 · 60 · 65 · 70 · 80
Length (cm) 12 · 14 · 16 · 18 · 20 · 22 · 24 · 26 · 28 · 30
Usual sizes 6, 7 and 8 Fr

3.3 End configuration available in the double J family

Abbreviation Description
OEO One open end
BEO Both ends open
BEC Both ends closed

3.4 Option codes of the MEDpro system

Code Set contents
/C With clamp
/G With guidewire
/S With suture
/SG With suture + guidewire
/SGC With suture + clamp + guidewire
/PS Orientable pusher (only sizes 6, 7 and 8 Fr)
/Px Pusher of length x cm

3.5 Colour, material and indwelling indication

Colour / Material Indwelling indication
White and Blue (Tecoflex® radiopaque) Standard stent, indwelling up to 30 days
Yellow Long Duro (Carbothane®) Long-term, indicated for tumour compression (over 30 days)

4. Equivalences and Cross-References

This ureteral stent MEDpro in Tecoflex® (blue or white) clinically corresponds to the family of standard polyurethane double J stents from other leading urology manufacturers, such as conventional ureteral stents from Cook Medical, the standard range from Bard, and the medium dwell time lines from Coloplast/Porges, Teleflex/Rüsch and Boston Scientific. The usual calibres in these procedures (6, 7 and 8 Fr) are interchangeable with standard ureteral access systems on the market.

Reference MEDpro Equivalent description
DJSBEM-S Same stent-only configuration with added suture
DJSBEM-EMP Same stent-only configuration with standard pusher
DJSBEM-A Same configuration in Long Duro Yellow (Carbothane®, dwell time exceeding 30 days)

To confirm the exact equivalent reference from another brand or for tender projects and closed operating theatre protocols, please consult our technical-commercial department indicating the manufacturer code you already use.

5. Selection tips and variants of interest

  • Calibre and length: select the size (x0.1 Char) according to the ureteral diameter and the length in cm according to the patient’s height and the estimated distance between the renal pelvis and the ureteral meatus. Sizes from 30 to 80 and lengths from 12 to 30 cm are available, configurable on request.
  • Dwell time type: if the expected dwell time does not exceed 30 days, this blue or white version in Tecoflex® is the most cost-effective option. If a prolonged stay is anticipated (tumour compression), consider the Long Duro Yellow version in Carbothane® (e.g. DJSBEM-A).
  • End configuration: consider OEO (one open end), BEO (both open) or BEC (both closed) according to the technical preference of the service and the clinical indication.
  • If you need placement accessories: versions are available with suture (DJSBEM-S), with clamp (DJSBEM-C-EMP), with guidewire (DJSBEM-G), with suture and guidewire (DJSBEM-SG), or with the complete set suture + clamp + guidewire (DJSBEM-SGC), as well as variants with pusher.
  • Other configurations in the same range: see the multi-loop variant at one end only (DJSOEM family) or the single-loop at both ends (DJSBES family).
  • Use and maintenance: MEDpro ureteral stents are supplied in a peelable sterile package, are intended for single-use and periodic evaluation is recommended during the dwell time indicated by the manufacturer.

Additional information

Tipo stent

BEC – Both Ends Closed, BEO – Both Ends Open, OEO – One Open End

Reference

DJSBEM

Manufacturer

MEDpro

Material

Tecoflex® radiopaque (standard polyurethane)

Configuration

Stent only (without accessories)

End type

Multiple loop at both ends (anchoring in renal pelvis and bladder)

Indwelling time

Up to 30 days (standard stent)

Radiopacity

Yes, allows fluoroscopic control

Available sizes

30, 35, 38, 40, 45, 47, 48, 50, 55, 60, 65, 70 and 80 (x0.1 Char)

Available lengths

12 to 30 cm

Calibres

6, 7 and 8 Fr

End configurations

OEO, BEO, BEC

Sterilisation

Sterile peel-open package, single-use product

Presentation

Individual sterile package; box (see units)

Calibre ch

3 Ch, 3.5 Ch, 3.8 Ch, 4 Ch, 4.5 Ch, 4.7 Ch, 4.8 Ch, 5 Ch, 5.5 Ch, 6 Ch, 6.5 Ch, 7 Ch, 8 Ch

Longitud

1.4 cm, 1.6 cm, 12 cm, 18 cm, 20 cm, 22 cm, 24 cm, 26 cm, 28 cm, 30 cm

Color

Blue, White