We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Turpa-type electrode (TURP) or cutting loop for ablation and coagulation of soft tissues, with double stem (DS), compatible with Storz resectoscope – Monopolar radiofrequency, sterile single-use

33,34 €

Turpa-type electrode (TURP) or cutting loop for ablation and coagulation of soft tissues in endoscopic urological surgery, with double stem (DS) and compatible fitting with Storz resectoscopes. Monopolar device that delivers radiofrequency energy supplied by an electrosurgical generator authorised for medical use, manufactured from stainless steel and presented in a sterile single-use package. It offers consistent cutting and haemostasis performance with a very competitive cost per procedure. Price per unit; minimum order of a box of 5 units.

Pedido mínimo de 5 unidades por condiciones del fabricante.

International shipping. Import duties and taxes are payable by the recipient.

Reference
TE-XDSS
Brand
MEDpro

Description

1. Introduction

The Turpa-type electrode (TURP), also known as the cutting loop, is the electrosurgery consumable that your urology department needs to perform ablation and coagulation of soft tissues with precision, safety and a very competitive cost per procedure. Its double-stem (DS) configuration and its compatible fit with Storz resectoscopes ensure a firm and stable coupling throughout the resection. It is supplied sterile and single-use, ready to open in the operating theatre, which eliminates the costs and risks of reprocessing the instrument.

2. Technical explanation of the device

This electrode is an active monopolar element that attaches to the working element of the resectoscope and transmits radiofrequency energy supplied by an electrosurgical generator authorised for medical use. The Turpa-type cutting loop geometry reproduces the classic design of transurethral resection (TUR): the active loop incises, vaporises and resects soft tissue with great precision, while its surface is equally effective for coagulating and controlling bleeding in vascular beds. The double stem (DS) provides a more stable fixation within the guide of the working element, reducing tip mobility during manipulation and facilitating uniform contact with the tissue. It is manufactured from medical-grade stainless steel, ensuring conductivity, resistance and a correct response to the high temperatures of the procedure.

3. Technical Specifications

The main features of the Turpa-type double-stem electrode are detailed below:

Characteristic Detail
SKU TE-XDSS
Electrode type Turpa (TURP) / cutting loop for ablation and coagulation
Function Ablation and coagulation of soft tissues
Stem configuration Double stem (DS – double stem)
Compatibility Storz brand resectoscopes (S/ Storz) and compatible brands
Energy type Monopolar radiofrequency (RF)
Material Medical-grade stainless steel
Sterilisation Sterile package, single-use
Presentation Price per unit; minimum order of a box of 5 units

Customisable product according to the combinations of the Turpa series:

Combination Available options
Size (Ch / Fr.) 22, 24, 27 (check availability for double stem)
Grade 30
Shaft type DS – Double stem
Resectoscope S/ Storz (compatible)

4. Equivalences and Cross-References

The TE-XDSS reference is a single-use replacement designed to replace the original Turpa-type electrodes of Storz resectoscopes and other brands compatible with the same double-stem fitting. For equipment with a single-stem working element, Medpro offers the TE-XSSS variant (Storz), as well as versions for Lobo (TE-SSW) and Olympus (TE-SSO). In the same family of electrodes for ablation and coagulation you will also find the ball electrode (BAE-D and BAE-S), the Collings-type knife (CGK-XDSS, CGK-XSSS, CGK-SSW and CGK-SSO), the cold knife (COK-DSX and COK-PRO) and the flexible bee-type electrodes (BUE-PRO and BUECIB-PRO).

Reference Shaft Resectoscope Gauge
TE-XDSS Double (DS) Storz (S/) See combination
TE-XSSS Single (SS) Storz (S/) 22, 24, 27 Ch
TE-SSW Single (SS) Lobo (W/) 24 Ch
TE-SSO Single (SS) Olympus (O/) 24 Ch
BAE-D Double (DS) Storz (S/) Ball 3–5 mm
CGK-XDSS Double (DS) Storz (S/) 24, 27 Ch
COK-DSX Double (DS) Storz (S/) 24 Fr

5. Selection tips and variants of interest

To choose correctly, check the calibre of your resectoscope and the type of fitting of the working element: the double stem (DS) is indicated for Storz-compatible housings with a double guide, while the single stem (SS) adapts to Storz, Lobo or Olympus systems. If your stock of optics is Wolf or Olympus, consider the single-stem variants of the Turpa series (TE-SSW and TE-SSO). As it is a single-use device, calculate the consumption per procedure and maintain a minimum safety stock so as not to interrupt surgical activity. With the Medpro family you can unify all electrode consumption in your urology department under the same quality criterion. Price per unit, with a minimum order of a box of 5 units. Consult our technical-commercial team to confirm exact compatibility with your equipment before placing the order.

Additional information

Electrode type

Turpa (TURP) / cutting loop for ablation and coagulation

Configuration

Double stem (DS – double stem)

Compatibility

Storz brand resectoscopes (S/ Storz) and compatible brands

Energy type

Monopolar radiofrequency (RF)

Material

Medical-grade stainless steel

Grade

30

Customisable calibres

22, 24, 27 Ch (check availability for double stem)

Sterilisation

Sterile package, single-use

Presentation

Price per unit; minimum order of a box of 5 units

Use

Ablation and coagulation of soft tissues in transurethral resection (TURP)

Brand

Medpro

Reviews

There are no reviews yet.

Be the first to review “Turpa-type electrode (TURP) or cutting loop for ablation and coagulation of soft tissues, with double stem (DS), compatible with Storz resectoscope – Monopolar radiofrequency, sterile single-use”

Your email address will not be published. Required fields are marked *