Parker Eclipse 3D-4D protective cover for vaginal and anal ultrasound probe | Pre-gelled with Aquasonic 100 gel | Latex-free polyethylene, non-sterile | Measurements 83 mm to 43 mm x 241 mm | Box of 100 units | Ref. E38-03

107,11 €

Protective cover for vaginal and anal ultrasound probe from the brand Parker, model Eclipse, pre-gelled inside with acoustic transmission gel Aquasonic 100. Made of latex-free polyethylene, in a non-sterile single-use presentation with individual packaging, it fits precisely to wider endocavitary transducers, including 3D/4D types, ensuring an artefact-free image and an effective hygienic barrier between patient and equipment. Measurements: 83 mm to 43 mm × 241 mm (8.3 cm to 4.3 cm × 24.1 cm). Presentation in a box of 100 units. Ref. E38-03.

International shipping. Import duties and taxes are payable by the recipient.

Reference
E38-03

Description

1. Commercial Introduction

The protective cover for ultrasound probe Parker Eclipse (Ref. E38-03) is the ideal barrier consumable for diagnostic imaging services that perform vaginal and anal endocavitary ultrasound examinations with wider transducers, including 3D/4D probes. Each cover is pre-gelled inside with Parker Aquasonic 100 gel, which eliminates the prior application of gel, reduces preparation time and prevents air bubbles on the transducer lens.

Designed for hospitals, gynaecology clinics, assisted reproduction units, urology and proctology practices and primary care centres, this latex-free polyethylene cover optimises daily workflow, prevents cross-contamination between patients and protects the transducer head from residues and mechanical damage. It is supplied in a box of 100 units with individual ready-to-use packaging.

2. Technical explanation of the procedure

During endocavitary ultrasound, the transducer is inserted into natural body cavities (vaginal or rectal), making it essential to place a single-use barrier between the probe and the mucous membranes. The Eclipse cover completely covers the transducer head and part of the probe body, preventing direct contact and reducing the risk of cross-contamination between patients, without the need to apply additional gel inside.

Its pre-gelled design places the coupling medium directly between the transducer lens and the inner surface of the cover, improving acoustic transmission and the quality of the diagnostic image. The polyethylene provides flexibility, softness and a firm, wrinkle-free fit, with a pleasant feel for the patient. As it is a non-sterile and disposable product, it must not be reused or re-sterilised; single-use covers do not replace the cleaning or high-level disinfection of the transducer required by the centre’s protocol.

3. Technical Specifications

The main features of this reference are detailed below, according to the manufacturer’s official information:

Characteristic Specification
Reference (SKU) E38-03
Manufacturer Parker Laboratories
Model Eclipse (version for wider 3D/4D transducers)
Product type Disposable protective sheath for endocavitary ultrasound probe
Material Medical-grade polyethylene, latex-free
Integrated gel Aquasonic 100, acoustic transmission gel pre-gelled inside
Measurements 83 mm to 43 mm × 241 mm (8.3 cm to 4.3 cm × 24.1 cm)
Sterility Non-sterile. Not re-sterilisable
Format Flat, with individual ready-to-use packaging
Compatibility Endocavitary probes and transducers (vaginal and rectal), including wider 3D/4D models
Applications Vaginal, rectal/anal ultrasound and diagnostic imaging
Use Single-use, disposable
Presentation Box of 100 units

Within Parker’s Eclipse range, the measurements determine the choice of reference according to the transducer width:

Reference Maximum width Reduced width Length Recommended application
E38-01 60 mm 44 mm 241 mm Standard endocavitary catheters
E38-03 83 mm 43 mm 241 mm Wider 3D/4D endocavitary catheters

4. Equivalences and Cross-References

This cover belongs to Parker’s Eclipse range, in which the width of the format varies according to the transducer. Reference E38-01 offers the same pre-gelled cover in standard width (60 mm to 44 mm × 241 mm) for conventional endocavitary probes, and reference 0380 (6 cm reduced to 4 × 24 cm) covers transducers of smaller diameter within the same line of pre-gelled covers with incorporated gel.

As latex-free endocavitary alternatives in the Cahnos catalogue, the sterile polyurethane PULL UP covers (Refs. 1-519-2524 and 1-519-2548, telescopic kit with gel and bands), the sterile polyurethane CIV-FLEX covers (Refs. 610006 and 610999) or the latex-free polyisoprene ULTRA COVER PIP covers (Refs. 88632PIP and 88681PIP) may be considered, interchangeable for transducer protection barrier purposes depending on availability and material preference.

Reference Measurements Material Format
E38-03 83 to 43 mm × 241 mm Latex-free polyethylene Pre-gelled cover with Aquasonic 100
E38-01 60 to 44 mm × 241 mm Latex-free polyethylene Pre-gelled cover with Aquasonic 100
610006 11.9 to 3.8 × 60 cm Latex-free polyurethane Sterile kit with cloth, gel and elastic bands
1-519-2524 11.9 to 3.8 × 61 cm Latex-free polyurethane Sterile telescopic kit
88632PIP 3.6 × 30 cm Latex-free polyisoprene Sterile cover, box of 10 units

At market level, this cover acts as a functional equivalent of the latex-free endocavitary protectors distributed by Dahlhausen (Refs. 42.200.26.301 and 42.200.30.201) and of the pre-gelled transducer protections of the same Eclipse family, interchangeable for probe protection barrier purposes.

5. Selection tips and variants of interest

To choose the appropriate cover, you must verify two parameters: the width and length of the transducer and the level of asepsis required by the procedure. Reference E38-03, with a maximum opening of 83 mm, is indicated for endocavitary transducers of larger diameter, including 3D/4D probes; if your probe is of standard width, reference E38-01 (60 mm) will be tighter and more economical.

  • For procedures requiring strict sterility (guided biopsies, invasive techniques or immunocompromised patients), consider the sterile polyurethane or polyisoprene versions in the catalogue, since this Eclipse cover is non-sterile in presentation.
  • For patients with latex allergy or sensitivity, the latex-free polyethylene of this cover is a safe and well-tolerated option.
  • As this is a single-use product, we recommend calculating the centre’s monthly consumption and taking advantage of special B2B conditions for hospitals, clinics and purchasing groups.

Consult our technical-commercial department to confirm exact compatibility with your fleet of ultrasound scanners and to define the most appropriate reference for each examination protocol.

Additional information

Model

Eclipse (3D/4D)

Reference

E38-03

Material

Medical-grade polyethylene, latex-free

Measurements

83 mm to 43 mm × 241 mm (8.3 cm to 4.3 cm × 24.1 cm)

Gel included

Aquasonic 100 pre-gelled inside

Protection type

Endocavitary vaginal and anal

Use

Single-use, disposable. Do not re-sterilise

Format

Flat, individual packaging

Compatibility

Endocavitary transducers, including wider 3D/4D models

Application

Vaginal, rectal/anal ultrasound and diagnostic imaging

Presentation

Box of 100 units

Units per box

100

Esterilidad

Non-sterile

Reviews

There are no reviews yet.