Description
1. Commercial Introduction
The protective cover for ultrasound probe Parker Eclipse (Ref. E38-03) is the ideal barrier consumable for diagnostic imaging services that perform vaginal and anal endocavitary ultrasound examinations with wider transducers, including 3D/4D probes. Each cover is pre-gelled inside with Parker Aquasonic 100 gel, which eliminates the prior application of gel, reduces preparation time and prevents air bubbles on the transducer lens.
Designed for hospitals, gynaecology clinics, assisted reproduction units, urology and proctology practices and primary care centres, this latex-free polyethylene cover optimises daily workflow, prevents cross-contamination between patients and protects the transducer head from residues and mechanical damage. It is supplied in a box of 100 units with individual ready-to-use packaging.
2. Technical explanation of the procedure
During endocavitary ultrasound, the transducer is inserted into natural body cavities (vaginal or rectal), making it essential to place a single-use barrier between the probe and the mucous membranes. The Eclipse cover completely covers the transducer head and part of the probe body, preventing direct contact and reducing the risk of cross-contamination between patients, without the need to apply additional gel inside.
Its pre-gelled design places the coupling medium directly between the transducer lens and the inner surface of the cover, improving acoustic transmission and the quality of the diagnostic image. The polyethylene provides flexibility, softness and a firm, wrinkle-free fit, with a pleasant feel for the patient. As it is a non-sterile and disposable product, it must not be reused or re-sterilised; single-use covers do not replace the cleaning or high-level disinfection of the transducer required by the centre’s protocol.
3. Technical Specifications
The main features of this reference are detailed below, according to the manufacturer’s official information:
| Characteristic | Specification |
|---|---|
| Reference (SKU) | E38-03 |
| Manufacturer | Parker Laboratories |
| Model | Eclipse (version for wider 3D/4D transducers) |
| Product type | Disposable protective sheath for endocavitary ultrasound probe |
| Material | Medical-grade polyethylene, latex-free |
| Integrated gel | Aquasonic 100, acoustic transmission gel pre-gelled inside |
| Measurements | 83 mm to 43 mm × 241 mm (8.3 cm to 4.3 cm × 24.1 cm) |
| Sterility | Non-sterile. Not re-sterilisable |
| Format | Flat, with individual ready-to-use packaging |
| Compatibility | Endocavitary probes and transducers (vaginal and rectal), including wider 3D/4D models |
| Applications | Vaginal, rectal/anal ultrasound and diagnostic imaging |
| Use | Single-use, disposable |
| Presentation | Box of 100 units |
Within Parker’s Eclipse range, the measurements determine the choice of reference according to the transducer width:
| Reference | Maximum width | Reduced width | Length | Recommended application |
|---|---|---|---|---|
| E38-01 | 60 mm | 44 mm | 241 mm | Standard endocavitary catheters |
| E38-03 | 83 mm | 43 mm | 241 mm | Wider 3D/4D endocavitary catheters |
4. Equivalences and Cross-References
This cover belongs to Parker’s Eclipse range, in which the width of the format varies according to the transducer. Reference E38-01 offers the same pre-gelled cover in standard width (60 mm to 44 mm × 241 mm) for conventional endocavitary probes, and reference 0380 (6 cm reduced to 4 × 24 cm) covers transducers of smaller diameter within the same line of pre-gelled covers with incorporated gel.
As latex-free endocavitary alternatives in the Cahnos catalogue, the sterile polyurethane PULL UP covers (Refs. 1-519-2524 and 1-519-2548, telescopic kit with gel and bands), the sterile polyurethane CIV-FLEX covers (Refs. 610006 and 610999) or the latex-free polyisoprene ULTRA COVER PIP covers (Refs. 88632PIP and 88681PIP) may be considered, interchangeable for transducer protection barrier purposes depending on availability and material preference.
| Reference | Measurements | Material | Format |
|---|---|---|---|
| E38-03 | 83 to 43 mm × 241 mm | Latex-free polyethylene | Pre-gelled cover with Aquasonic 100 |
| E38-01 | 60 to 44 mm × 241 mm | Latex-free polyethylene | Pre-gelled cover with Aquasonic 100 |
| 610006 | 11.9 to 3.8 × 60 cm | Latex-free polyurethane | Sterile kit with cloth, gel and elastic bands |
| 1-519-2524 | 11.9 to 3.8 × 61 cm | Latex-free polyurethane | Sterile telescopic kit |
| 88632PIP | 3.6 × 30 cm | Latex-free polyisoprene | Sterile cover, box of 10 units |
At market level, this cover acts as a functional equivalent of the latex-free endocavitary protectors distributed by Dahlhausen (Refs. 42.200.26.301 and 42.200.30.201) and of the pre-gelled transducer protections of the same Eclipse family, interchangeable for probe protection barrier purposes.
5. Selection tips and variants of interest
To choose the appropriate cover, you must verify two parameters: the width and length of the transducer and the level of asepsis required by the procedure. Reference E38-03, with a maximum opening of 83 mm, is indicated for endocavitary transducers of larger diameter, including 3D/4D probes; if your probe is of standard width, reference E38-01 (60 mm) will be tighter and more economical.
- For procedures requiring strict sterility (guided biopsies, invasive techniques or immunocompromised patients), consider the sterile polyurethane or polyisoprene versions in the catalogue, since this Eclipse cover is non-sterile in presentation.
- For patients with latex allergy or sensitivity, the latex-free polyethylene of this cover is a safe and well-tolerated option.
- As this is a single-use product, we recommend calculating the centre’s monthly consumption and taking advantage of special B2B conditions for hospitals, clinics and purchasing groups.
Consult our technical-commercial department to confirm exact compatibility with your fleet of ultrasound scanners and to define the most appropriate reference for each examination protocol.