Description
1. Commercial Introduction
Keep the surgical field clean, clear and safe with the sterile surgical suction tube ORNEX of 6 mm × 1.8 m, in non-conductive version and with F/MVC connectors. An essential reference for operating theatre, emergency, ICU, hospitalisation, wound dressing rooms and ENT services, manufactured by ORNEX within the recognised fluid management range from Medline. Its fingertip vacuum control system gives the professional precise and immediate management of suction, avoiding interruptions and reducing noise during the procedure.
2. Technical explanation of the equipment and procedure
This sterile tube is integrated into the suction circuit between the vacuum system or surgical suction unit and the suction accessories (Yankauer cannulas, tracheal and bronchial suction catheters or catheters). Its internal diameter of 6 mm ensures optimal flow rate and a stable flow of blood, secretions and fluids, keeping the lumen of the tube open even during prolonged suction and minimising the risk of collapse or obstruction. The differential feature is the MVC vacuum control (MED-STOP type): a lateral port that, when occluded with the finger, instantly regulates the negative pressure transmitted to the distal end, allowing suction to be adjusted without interrupting the procedure or modifying the regulator on the central outlet. As it is a non-conductive version, it offers maximum electrical safety against stray currents, and its flexible medical-grade material, resistant to kinking, facilitates ergonomic handling throughout the procedure.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference (SKU) | ORNEX66VC |
| Product type | Sterile surgical suction tube with vacuum control |
| Diameter | 6 mm |
| Length | 1.8 m (180 cm) |
| Connectors | F/MVC (male/female with vacuum control) |
| Vacuum control | Yes, MVC system operated by fingertip |
| Conductivity | Non-conductive |
| Sterility | Sterile, single-use |
| Material | Medical-grade flexible, kink-resistant |
| Application | Suction of fluids and secretions in surgical and post-surgical procedures |
| Recommended use | Operating theatre, ICU, emergency, hospitalisation and ENT |
| Compatibility | Yankauer cannulas, suction catheters, surgical suction units and hospital vacuum systems |
| Manufacturer | ORNEX (Medline) |
Range of ORNEX tubes with vacuum control:
| Reference | Diameter | Length | Conductivity |
|---|---|---|---|
| ORNEX66VC | 6 mm | 1.8 m | Non-conductive (F/MVC) |
| ORNEX56VC | 5 mm | 1.8 m | Non-conductive (F/F + MVC) |
| ORNEX56VCNS | 5 mm | 1.8 m | Conductive (F/MVC) |
4. Equivalences and Cross-References
This tube belongs to the ORNEX surgical suction range (Medline), a reference manufacturer in surgical fluid management. Its most direct equivalent in terms of control system and conductivity is the ORNEX56VC (5 mm × 1.8 m, F/F + MVC, non-conductive), which shares valve and application with a smaller flow diameter; the conductive variant of identical configuration is the ORNEX56VCNS (5 mm × 1.8 m, F/MVC). In non-sterile format with MED-STOP control are the tubes ORNEX66VCA (6 mm × 1.8 m, adult), ORNEX66VCP (6 mm × 1.8 m, paediatric) and ORNEX610VCA (6 mm × 3 m, adult). The sterile tubes without control ORNEX610 (6 mm × 3 m) and ORNEX66A (6 mm × 1.8 m) share dimensions and universal connectors, and the roll ORNEX6100 (6 mm × 30 m) allows custom replacement in vacuum network installations. The MVC control is also marketed as a loose accessory in references OR853VCA (adult) and OR854VCP (paediatric). The connectors in the range are compatible with universal suction tube connectors (OR350A, OR351, OR352 and OR356) and with most suction units and vacuum systems on the market, as well as with the Yankauer cannula sets ORNEX66AY1200 and ORNEX610Y1800.
5. Selection tips and variants of interest
Conductivity: the non-conductive version ORNEX66VC is the recommended option when maximum electrical safety against stray currents is sought; if the environment uses electrosurgical equipment and dissipation of static charges is required, consider the conductive variant ORNEX56VCNS.
Diameter and length: the 6 mm tube is the standard size for general suction with medium-high flow, and the 1.8 m offers a comfortable working radius around the patient; if greater reach is required, choose the 3 m version (ORNEX610VCA).
Vacuum control: the fingertip MVC system is the most practical and ergonomic option when the procedure requires frequent interruption or modulation of suction, as it avoids releasing the tube and reduces vacuum losses.
Sterility: being sterile, it is suitable for direct contact with the sterile field; for the external suction circuit you can opt for the non-sterile versions ORNEX66VCA or ORNEX610VCA.
Compatibility: verify that your suction unit has a universal connector and that the catheter diameter fits tightly; the ORNEX family adapts to most hospital vacuum systems and intermediate accessories in the range. For B2B volume conditions, continuous supply contracts or purchasing centre budgets, contact our technical-commercial team at Cahnos.