Description
1. Introduction
The medical-grade silicone tube is the reference consumable for completing the surgical suction circuit: it connects the suction unit to the catheter or suction cannula, maintaining a stable vacuum, efficient fluid conveyance and maximum hygiene in the operating theatre, emergency department, consulting rooms and hospital wards. Made from 100% medical-grade silicone, it stands out for its flexibility, transparency and complete absence of odour, as well as excellent thermal resistance that allows autoclaving and continuous use in demanding healthcare environments. It is supplied in rolls of 30 or 100 metres, in a very wide range of diameters and thicknesses, so that each department can select the most suitable size for its equipment.
2. Technical explanation
In surgical suction systems, the effectiveness of suction depends on the airtightness of the entire circuit: vacuum-generating equipment, silicone tube, adapters and distal catheter. This tube acts as a conduction line between the suction unit and the patient, safely transporting secretions and fluids to the collection canister. Its 100% medical-grade silicone is particularly stable: thanks to the infrared vulcanisation process and the special oven heat treatment at 200 °C, the internal surface is smooth and non-stick, which prevents residue build-up, encrustation and coagulation phenomena. The transparency of the material allows visual monitoring of the aspirated flow, while its balanced hardness (60° Shore A) ensures a good compromise between flexibility, collapse resistance and durability against suction and cleaning and sterilisation cycles.
3. Technical Specifications
Data verified against the manufacturer’s official datasheet:
| Parameter | Specification |
|---|---|
| Raw material | HCR (high-consistency silicone rubber) |
| Colour | Translucent / transparent |
| Hardness | 60° ±5% Shore – DIN 53505 |
| Density | 1.17 g/cm³ – DIN 53479A |
| Elongation | 490/530% – DIN 53504S1 |
| Tear resistance | 34-35 N/mm – ASTM D 624 B |
| Thermal resistance | Resistant to hot air up to 200 °C |
| Treatment | Infrared vulcanisation; special oven treatment at 200 °C |
| Properties | Non-stick, prevents encrustation and coagulation; medical grade, transparent and odourless |
| Manufacture | Made in Spain / European Union |
Manufactured in the European Union in accordance with: US PHARMACOPOEIA XXI, EUROPEAN PHARMACOPEA, DIN 58367 – DIN 58362 – DIN 13098, FDA 177.2600, BGA XV parts A and B – BGA IX part B.
Available references
| Reference | Size | Thickness | Sales unit |
|---|---|---|---|
| GM25450 | 1×3 mm | 1 mm | Roll of 100 m |
| GM25451 | 2×4 mm | 1 mm | Roll of 100 m |
| GM25452 | 3×5 mm | 1 mm | Roll of 100 m |
| GM25453 | 4×6 mm | 1 mm | Roll of 100 m |
| GM25455 | 6×8 mm | 1 mm | Roll of 30 m |
| GM25458 | 3×6 mm | 1.5 mm | Roll of 30 m |
| GM25459 | 4×7 mm | 1.5 mm | Roll of 30 m |
| GM25460 | 5×8 mm | 1.5 mm | Roll of 30 m |
| GM25461 | 6×9 mm | 1.5 mm | Roll of 30 m |
| GM25462 | 7×10 mm | 1.5 mm | Roll of 30 m |
| GM25466 | 4×8 mm | 2 mm | Roll of 30 m |
| GM25467 | 5×9 mm | 2 mm | Roll of 30 m |
| GM25468 | 6×10 mm | 2 mm | Roll of 30 m |
| GM25469 | 8×12 mm | 2 mm | Roll of 30 m |
| GM25470 | 10×14 mm | 2 mm | Roll of 30 m |
| GM25474 | 5×10 mm | 2.5 mm | Roll of 30 m |
| GM25475 | 7×12 mm | 2.5 mm | Roll of 30 m |
| GM25476 | 8×13 mm | 2.5 mm | Roll of 30 m |
| GM25477 | 10×15 mm | 2.5 mm | Roll of 30 m |
| GM25480 | 6×12 mm | 3 mm | Roll of 30 m |
| GM25481 | 7×13 mm | 3 mm | Roll of 30 m |
| GM25482 | 8×14 mm | 3 mm | Roll of 30 m |
| GM25483 | 9×15 mm | 3 mm | Roll of 30 m |
| GM25484 | 10×16 mm | 3 mm | Roll of 30 m |
| GM25485 | 12×18 mm | 3 mm | Roll of 30 m |
| GM25488 | 8×15 mm | 3.5 mm | Roll of 30 m |
| GM25491 | 10×20 mm | 5 mm | Roll of 30 m |
Product data
| Manufacturer | GIMA |
|---|---|
| Device type | Medical device (medical device) |
| Device class | I |
| CND | V9099 |
| GMDN | 35917 |
4. Equivalences and Cross-References
This product is marketed under the Cahnos SKUs GM25450 to GM25491, corresponding to the manufacturer’s references. 25450 to 25491. There is no validated equivalence table cross-referencing this family of silicone tubes with specific codes from other manufacturers, so no direct 1:1 equivalences are indicated; the silicone tube is a universal connection consumable by size and thickness, but exact compatibility with each device must be verified by the tube’s inner and outer diameter. In the Cahnos catalogue, this family is complemented by the original surgical suction adapters – catheter adapter for the CLINIC, HOSPITAL and MAXI ASPEED suction units (ref. 28253), for the TOBI and SUPERTOBI suction units (ref. 28252) and for the ASPEED suction unit (ref. 28257) – as well as by the catheters, suction cannulas and Yankauers from the surgical suction range, with which it completes a leak-tight and reliable suction circuit. To confirm equivalence with another brand in tendering processes, please contact our technical-commercial department.
5. Selection tips and variants of interest
Select the tube size according to the connector or fitting of your suction unit and the diameter of the suction catheter: the finest references (1×3 mm to 3×5 mm) are suitable for neonatal, paediatric or small-bore suction circuits; the intermediate sizes (4×6 mm to 7×10 mm) are the usual choice for nasal, oral and tracheal suction in adults; and the larger sizes (8 mm and above, with wall thicknesses from 2 to 5 mm) are indicated for high-flow surgical suction and conveyance of thick fluids. Also choose the wall thickness according to the vacuum pressure of the device: the greater the negative pressure, the greater the recommended thickness to prevent tube collapse. For the supply of operating theatres and purchasing centres, the roll presentations (100 m for fine calibres and 30 m for larger ones) guarantee continuous availability of consumables. For large orders you can request a quote: ask our commercial team for B2B terms and lead times for your centre.