Replacement filter for your suction equipment
This replacement filter (Ref. 28239) keeps your suction system in full hygienic and performance condition. Designed as an original spare part for the Clinic, Clinic Plus and SuperVega units mounted on trolleys, it ensures that your suction circuits continue to operate with maximum microbiological safety. An essential consumable for operating theatres, consulting rooms and wound dressing units that work with surgical suction.
Technical explanation
The filter is a safety component inserted in the suction line between the patient and the vacuum source. Its hydrophobic treatment repels moisture and liquids, while its antibacterial filter medium retains microorganisms, aerosols and particles, preventing them from contaminating the equipment or dispersing into the environment. This protects both the patient and healthcare staff from cross-contamination and preserves the proper functioning of the vacuum circuit. It is installed using its 11 mm connector, specific to the indicated equipment.
Technical specifications
| Characteristic | Detail |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 28239 |
| Product type | Replacement filter for suction |
| Filter type | Hydrophobic and antibacterial |
| Connector | 11 mm |
| Compatibility | SuperVega on trolley, Clinic and Clinic Plus |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
| CND | A0680 |
| EAN | 8023279282399 |
Equivalences and cross-references
No reliable sources have been found containing a manufacturer-validated equivalence table that would allow references from other manufacturers to be declared as 1:1 interchangeable with reference 28239. This reference corresponds to the manufacturer’s original replacement filter for the Clinic, Clinic Plus and SuperVega on-trolley suction units. Before replacing any filter of another brand or validating an equivalence for tenders, we recommend consulting our technical-commercial department, which will check connector diameter, equipment compatibility and filter medium specifications.
Selection tips and variants of interest
Always check the connector diameter (11 mm) and the model of your suction unit before replacing the filter: this reference is the one indicated for Clinic, Clinic Plus and SuperVega mounted on trolley. Replace the filter when you observe saturation, loss of suction performance or after prolonged periods of use, following the manufacturer’s recommendations. If your equipment uses a different connection diameter or belongs to another family in the range, consult our team to identify the correct replacement. For B2B needs, volume purchases or central purchasing quotes, our technical-commercial department at Cahnos will advise you without obligation.