Description
1. Introduction
The antibacterial and hydrophobic replacement filter Ref. 28229 is the original spare part indicated for maintaining the safety and hygiene of your surgical suction system. It is designed for the suction equipment of codes 28190, 28209 to 28212, 28220 to 28225 and 28243, ensuring an effective barrier between the suction circuit and the facility’s vacuum line. An essential maintenance solution for operating theatre, ICU, emergency, wound dressing, hospitalisation and clinic services that require maximum microbiological protection conditions.
2. Technical explanation
In a surgical suction system, the central vacuum draws potentially contaminated air, secretions and aerosols through the pipework circuit. The replacement filter Ref. 28229 is inserted into the vacuum line and combines a hydrophobic membrane, which repels moisture and protects the equipment from liquid ingress, with an antibacterial action that retains microorganisms and prevents their spread through the suction network. This double barrier protects both the equipment and healthcare staff and patients, preventing cross-contamination and system saturation from moisture. When the filter becomes blocked or loses effectiveness, it must be replaced with the original reference to maintain suction performance and circuit safety conditions.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 28229 |
| Product type | Antibacterial and hydrophobic replacement filter for suction |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
| CND | A0680 |
| EAN | 8023279282290 |
Suction unit references compatible with this replacement filter:
| Compatible references | Description |
|---|---|
| 28190 | Suction unit |
| 28209, 28210, 28211, 28212 | Suction units (series 28209-28212) |
| 28220, 28221, 28222, 28223, 28224, 28225 | Suction units (series 28220-28225) |
| 28243 | Suction unit |
4. Equivalences and Cross-References
This product corresponds to reference 28229. There is no manufacturer-validated equivalence table cross-referencing this reference with filters from other manufacturers on a 1:1 interchangeable basis. For a possible substitution with another brand, compatibility (connection, diameter, membrane type and device class) must be validated field by field with the Cahnos technical department before use as a stock replacement or in tendering.
5. Selection tips and variants of interest
First identify the exact reference of your suction unit: use this filter (Ref. 28229) for the suction units of codes 28190, 28209 to 28212, 28220 to 28225 and 28243. Replace the filter upon loss of suction performance, moisture ingress into the vacuum line or according to your facility’s preventive maintenance plan. As it is a class II A medical device, it must be purchased and managed in accordance with applicable regulations. For volume orders, supply contracts or purchasing centre quotes, contact our technical-commercial team at Cahnos, who will confirm exact compatibility and provide a formal quote tailored to your needs.