Description
1. Commercial Introduction
The 35 mm hysterography cup (Ref. 29922) is the reference gynaecological device for contrast studies of the uterine cavity and hysterosalpingography. Its frustoconical dome design with vacuum system provides a leak-proof, comfortable and reliable cervical seal, and its sterile single-use presentation makes it the ideal choice for gynaecological radiology services, gynaecology clinics, operating theatres and diagnostic imaging units. A hospital-grade medical device, latex-free, that is part of the complete series of hysterography cups.
2. Technical explanation of the product and procedure
The cup consists of a rigid, transparent frustoconical dome with a central conical cannula. It incorporates a flexible 25 cm long manipulator attached to the dome and two tubes fitted with clamps: one connects to the vacuum source and the other is intended for injecting the radiopaque contrast medium.
The procedure is based on placing the dome over the cervix: its frustoconical shape and the progressive application of vacuum ensure perfect adherence to the cervix through automatic centring, preventing contrast reflux. The dome-cannula unit is radiotransparent, allowing the proximal area of the endocervix to be monitored during the examination. Thanks to the manipulator, the radiologist can immobilise and comfortably orient the uterus while remaining at a distance from the radiological field, improving ergonomics and diagnostic quality.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Brand | |
| Manufacturer reference | 29922 |
| Product type | Hysterography cup (dome) – 35 mm – sterile |
| Presentation | 1 unit (1 pc), sterile, single-use |
| Cup size | 35 mm |
| Design | Rigid, transparent frustoconical dome with central conical cannula |
| Manipulator | Flexible and foldable, 25 cm long, attached to the dome |
| Tubes | Two tubes with clamps (vacuum and contrast medium injection) |
| Sealing system | Progressive vacuum with self-centring on the cervix |
| Radiotransparency | Radiotransparent dome/cannula unit |
| Latex | Latex-free (no latex) |
| Minimum order | 10 |
| Device type | Medical device (Medical device) |
| Device class | I S |
| CND | U080102 |
| EAN | 8023279299229 |
Available references in the series
| Reference | Description | Presentation |
|---|---|---|
| 29920 | Hysterography cups – 25 mm | Sterile |
| 29921 | Hysterography cups – 30 mm | Sterile |
| 29922 | Hysterography cups – 35 mm (current product) | Sterile |
| 29923 | Connector for hysterography cups | Sterile |
4. Equivalences and Cross-References
This product belongs to the series of sterile hysterography cups and shares the system, accessories and presentation with the 25 mm (Ref. 29920) and 30 mm (Ref. 29921) cups, as well as with the sterile connector common to all three sizes (Ref. 29923).
Functionally, the vacuum cup concept for hysterography/hysterosonography is comparable to the suction cup catheters PM-CARE® 2V-CUP from Prince Medical (Refs. PS4292340, PS4292840, PS4293540 and set PS3460845), also present in the Cahnos catalogue. No reliable source has been found with a manufacturer-validated 1:1 equivalence table that would allow Ref. 29922 to be cross-referenced with specific codes from other suppliers; for any stock substitution or use in tenders, please consult our technical-commercial department to verify calibre, length and fixation system.
5. Selection tips and variants of interest
Select the hysterography cup according to the cervical diameter required by your service protocol: Ref. 29920 (25 mm) for standard procedures, Ref. 29921 (30 mm) as an intermediate option and Ref. 29922 (35 mm) for larger cervical diameters. The Ref. 29923 connector is common to all three sizes, so a single connector reference serves the entire range of cups.
As this is sterile single-use material, we recommend sizing the minimum order of 10 units per reference to ensure availability in the operating theatre and in the radiology service. Medical device class I S; for B2B volume conditions or specific equipment needs, contact the technical-commercial team at Cahnos. For large orders you can request a quote.