Description
1. Introduction
The Catheter Exchange Set 8 with Latex Gloves and Glyco-SID® from Medline is the ready-to-use solution that your urology department or hospital ward needs to perform bladder catheterisation or scheduled replacement of transurethral urinary catheters in a sterile, hygienic and quick manner. Each set groups all the essential components of the procedure in a single sterile package, simplifying the preparation of the dressing trolley, reducing nursing time and minimising the risk of contamination during the procedure. A standard item in the Medline urology product catalogue, indicated for hospitals, clinics and social-healthcare centres.
2. Technical explanation of the equipment and procedure
This kit is designed for the one-time placement or change of transurethral urinary catheters when urine drainage is required. The plastic urine collection tray acts as a drainage receptacle and support for the material, while the gauze balls, compresses and forceps allow aseptic cleaning and handling of the field. The impermeable fenestrated drape and sheet, both 60 x 60 cm, delimit the sterile field and protect the work surface. The powder-free latex examination gloves, in medium size, guarantee protection for both the professional and the patient throughout the procedure.
The great advantage of this set is the inclusion of the pre-filled 10 ml Aquadest Glyco-SID® syringe, which allows prior lubrication of the urethral meatus with a 10% glycerin solution, facilitating the introduction of the catheter and improving the comfort and safety of the technique. As it is a sterile single-use set, the risk of cross-contamination and the costs of reprocessing the material are eliminated.
3. Technical Specifications
The standard set is part of the Medline urology product catalogue and includes the following components:
| Component | Quantity | Features |
|---|---|---|
| Urine collection tray | 1 | Plastic |
| Gauze balls | 6 | Egg size |
| Compresses | 2 | 7.5 x 7 cm |
| Forceps | 2 | For aseptic handling |
| Fenestrated drape | 1 | 60 x 60 cm, impermeable |
| Latex examination gloves | 1 pair | Powder-free, medium size, wrapped in paper |
| Pre-filled Aquadest Glyco-SID® syringe | 1 | 10% glycerin solution, 10 ml |
| Sheet | 1 | 60 x 60 cm, impermeable |
Available references
| Reference | Glove size | No. of components | Units per box |
|---|---|---|---|
| S-080000 | Medium | 15 | 20 |
Specifications
| Characteristic | Detail |
|---|---|
| Glove material | Latex |
| Lubrication | Pre-filled Glyco-SID® syringe (10% glycerin, 10 ml) |
| Presentation | Sterile, single-use set |
| Manufacturer | Medline |
| Medline family | P-FJ77T |
| Use | Bladder catheterisation / exchange of transurethral catheters |
4. Equivalences and Cross-References
Within the Medline urology catalogue, this set corresponds to references MDLP-FJ77T, P-FJ77T and S-080000, with the latter (S-080000) being the commercial purchasing reference in a presentation of 20 units per box.
Variants within the same catheter exchange range include:
- Catheter Exchange Set 9 with Vinyl Gloves and Glyco-SID® (Ref. S-090000): 12 components and vinyl gloves in large size; suitable alternative for latex and nitrile allergies.
- Catheter Exchange Set 7 with Latex Gloves and Tray (Ref. S-070000): 14 components and medium-sized latex gloves.
- Catheter Exchange Set 6 with Nitrile Gloves (Ref. S-060000-N): 16 components and nitrile gloves; recommended option for latex sensitivity.
No official cross-reference table has been found in public sources to validate an exact 1:1 equivalence with sets from other manufacturers; equivalences must be validated field by field (number of components, glove material and size, sterility and presentation) with the technical department before substitution in a tender.
5. Selection tips and variants of interest
Always verify the glove size and material required by your protocol: this set includes a pair of powder-free latex examination gloves in medium size, wrapped in paper. If your protocol requires prior lubrication of the urethral meatus with glycerin, the included 10 ml Glyco-SID® syringe allows you to do this directly, speeding up the procedure. If your facility requires vinyl or nitrile gloves due to latex allergy or sensitivity, please consult variants S-090000 (vinyl) or S-060000-N (nitrile) from the same range.
Always check the integrity of the sterile packaging before use and follow the centre’s clinical protocols for asepsis, catheterisation and catheter fixation. Single-use product: do not resterilise or reuse. For B2B contracting conditions, tenders or high-volume orders, please contact our technical-commercial team.




Reviews