Description
1. Introduction
The Catheter Exchange Set 6 with Latex Gloves and Urine Collection Tray from Medline is the ready-to-use solution that your urology department or hospital ward needs for performing sterile, hygienic and quick bladder catheterisation or scheduled replacement of transurethral urinary catheters. Each set gathers all the essential components of the procedure in a single sterile package, simplifying the preparation of the dressing trolley, reducing nursing time and minimising the risk of contamination during the procedure. A standard in the Medline urology product catalogue, designed for hospitals, clinics and social healthcare centres.
2. Technical explanation of the equipment and procedure
This kit is designed for single-use placement or replacement of transurethral urinary catheters when the patient needs urine drainage. The plastic urine collection tray acts as a drainage receptacle and material support, while the gauze swabs, gauze pads and forceps allow cleaning and aseptic manipulation of the field. The waterproof drape with opening of 50 x 50 cm delineates the sterile field over the patient and the waterproof sheet of 60 x 60 cm protects the work surface.
The latex examination gloves, powder-free, ensure protection for the professional and the patient throughout the procedure: the set includes one pair in large size (wrapped in paper) and one additional glove in size mediana with folded cuff, covering the usual needs of the team. Being a sterile single-use set, the risk of cross-contamination and material reprocessing costs are eliminated.
3. Technical Specifications
The standard set is part of the Medline urology product catalogue and includes the following components:
- 1 urine collection tray (plastic)
- 5 gauze balls (plum size)
- 5 compresses (7.5 x 7.5 cm)
- 1 forceps
- 1 fenestrated drape (50 x 50 cm, impermeable)
- 1 pair of latex examination gloves (powder-free, large size, wrapped in paper)
- 1 latex examination glove (powder-free, medium size, with folded cuff)
- 1 sheet (60 x 60 cm, impermeable)
Available references
| Reference | Glove size | No. of components | Units per box |
|---|---|---|---|
| S-060000 | Medium | 16 | 40 |
Specifications
| Characteristic | Detail |
|---|---|
| Glove material | Latex |
| Presentation | Sterile, single-use set |
| Manufacturer | Medline |
| Medline family | P-OT19K |
| Use | Bladder catheterisation / exchange of transurethral catheters |
4. Equivalences and Cross-References
Within the Medline urology catalogue, this set corresponds to references MDLP-OT19K, P-OT19K and S-060000, the latter being the commercial purchase reference (40 units per box).
As variants of the same catheter exchange range, the following are available:
- Catheter Exchange Set 6 with Nitrile Gloves (Ref. S-060000-N): 16 components and 40 units per box, with powder-free nitrile gloves; recommended alternative in case of latex allergy or sensitivity.
- Catheter Exchange Set 7 with Latex Gloves and Tray (Ref. S-070000): 14 components, medium size latex gloves and 40 units per box.
- Catheter Exchange Set 8 with Latex Gloves and Glyco-SID (Ref. S-080000): 15 components and includes a pre-filled syringe with 10% glycerin solution (10 ml), in a presentation of 20 units per box; alternative to consider when the centre’s protocol requires lubrication with glycerin.
No official cross-reference table has been found in public sources that validates an exact 1:1 equivalence with sets from other manufacturers; equivalences must be validated field by field (number of components, material and glove size, sterility and presentation) with the technical department before a substitution in a tender.
5. Selection tips and variants of interest
Check the glove size required by your protocol: this set includes a pair of latex gloves in large size and one additional glove in size mediana, all powder-free. If your centre requires nitrile gloves due to latex allergy or sensitivity, consult the S-060000-N variant of the same series; if your protocol requires prior lubrication of the meatus with glycerin, consider the S-080000 variant with Glyco-SID.
Always check the integrity of the sterile package before use and follow the centre’s clinical protocols for asepsis, catheterisation and catheter fixation. Single-use product: do not re-sterilise or reuse. For B2B contracting conditions, tenders or large volume orders, consult our technical-commercial team.



Reviews
There are no reviews yet.