Description
1. Commercial Introduction
The disposable umbilical cord clamp (ref. 0943002) is the classic umbilical occlusion instrument for delivery rooms, maternity units, obstetrics services and neonatal units. It is a single-use, sterile device for immediate application, designed to ensure a firm, hygienic and reliable closure of the umbilical cord in the minutes after birth. Its price per unit and volume purchase format make it the ideal consumable for hospitals, clinics, birthing centres and B2B institutional purchasing that require a constant, traceable supply with the best cost-benefit ratio. Available with a minimum order of 100 units.
2. Technical explanation of the equipment and procedure
After birth, the umbilical cord must be occluded quickly and in a controlled manner to interrupt blood flow between the placenta and the newborn, allowing subsequent sectioning under aseptic conditions. The umbilical cord clamp performs this function through a mechanical pressure system: its jaws, fitted with serrated teeth, close over the cord and maintain stable, continuous compression while the stump dries and retracts.
The design incorporates an extra-secure structure that prevents accidental opening: once closed, the clamp can only be reopened by cutting the rear side, eliminating the risk of unwanted reopening during transfer or initial newborn care. As a single-use device, it is discarded after application, avoiding cleaning and re-sterilisation processes and reducing the risk of cross-contamination between patients.
Each unit is supplied individually packaged in coupled cellophane (nylon/polyethylene) and medical paper, ensuring maximum hygiene and safety until the moment of use, and has been sterilised with ethylene oxide (EtO), according to the official technical data sheet of the product.
3. Technical Specifications
The following specifications correspond to the official technical data sheet of the umbilical cord forceps ref. 0943002:
| Reference (SKU) | 0943002 |
| Product type | Single-use umbilical occlusion forceps (umbilical clamp) |
| Indication | Holding and occlusion of the umbilical cord after birth |
| Material | Medical-grade plastic, latex-free |
| Jaw design | Fine jaw with serrated teeth for firm, non-slip grip |
| Locking system | Extra-safe structure, non-reopenable; can only be opened by cutting the posterior side |
| Sterility | Sterile, sterilised with ethylene oxide (EtO) |
| Packaging | Individual: laminated cellophane (nylon/polyethylene) and medical paper |
| Use | Single-use (disposable) |
| Field of application | Delivery room, obstetrics, maternity and neonatal units |
| Presentation | Sold per unit; minimum order quantity 100 units |
Note: the previous commercial description referred to a reusable stainless steel body; this information is not supported by the official technical data sheet of the product, which defines it as a sterile single-use device. This data sheet has been corrected in accordance with the factory document.
4. Equivalences and Cross-References
The umbilical cord clamp is a standardised GMDN category (”Umbilical cord clamp, single-use”). The following references have been cross-checked against official catalogues and regulatory databases (GUDID); they all share indication, plastic material, sterility and locking mechanism, but as they come from different manufacturers they cannot be considered 1:1 interchangeable without prior validation:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| GIMA (Italy) | Disposable umbilical forceps X-SAFE | 107062 (DoctorShop) / 29942 (factory code) | Comparable by category (not interchangeable 1:1) | Same function, EtO sterile, latex-free, individual packaging in cellophane and medical paper, non-reopenable lock; supplied in a box of 500 units and manufactured in Europe (Italy). Confirm exact jaw dimensions. |
| Hollister / Aspen Surgical (USA) | Double-Grip Umbilical Cord Clamp | 9423 (GUDID DI 00840113231508) | Comparable by category (not interchangeable 1:1) | Sterile plastic clamp with double-grip serrated jaws and constant pressure on the cord; box of 125 units. Different geometry and presentation. |
| Medline (USA) | Umbilical Cord Clamp, plastic | DYNJ04220 (GUDID 10080196493401) / DYNJ04229 (GUDID 10080196820771) | Comparable by category (not interchangeable 1:1) | Plastic, sterile and latex-free, with grooved teeth and safety lock; presentation of 100 units/box. Verify locking and measurements in the manufacturer’s data sheet. |
There is no manufacturer-validated equivalence table cross-referencing reference 0943002 with specific codes from other brands; the previous comparisons are functional and categorical, verified against the official catalogue and GUDID, and should not be treated as 1:1 substitutes without prior validation of specifications, certifications and tender documents. Consult the technical department at Cahnos before using this reference in public tenders.
5. Selection tips and variants of interest
- Classic clamping system: ref. 0943002 is the traditional disposable plastic clamp solution; if your facility seeks a modern occlusion without a rigid clamp, consider the sterile elastic umbilical occlusion ring CETRO® Cordring 2.0 (ref. 9607S), especially in environments with latex restriction protocols.
- Complete delivery kits: for a turnkey delivery room supply, the Gynaecology and Obstetrics Set KER70025 includes a 5 cm Bahr clamp for clamping, non-woven gauze swabs and blunt-point scissors; set KER70023B also includes Kocher forceps for clamping and cutting the cord.
- Purchasing management: as this is a high-turnover product in maternity units, it is recommended to plan volume orders (minimum 100 units) and check the integrity of the individual packaging and the sterility date before each use.
- Prior verification: check the manufacturer’s technical data sheet for jaw dimensions and the accepted cord diameter if replacing with another brand in tenders or technical specifications.
- Waste management: as a single-use device, dispose of it after use in accordance with the centre’s healthcare waste regulations.