Description
1. Introduction
The open surgical instrument tray without lid (Refs. 26597, 26598, 26603 and 26604) is the practical, resistant and hygienic solution for keeping instruments organised, protected and always at hand during procedures and reprocessing cycles. A European benchmark in medical material, it is designed for professional use in operating theatres, sterilisation departments, treatment rooms, nursing practices, clinics and health centres. Its open format with angled edges facilitates quick access to forceps, scissors, needle holders, retractors and other surgical material, making it an essential item in the daily equipment of healthcare professionals.
2. Technical explanation
These trays belong to the family of sanitary holloware or stainless steel holloware and are manufactured in AISI 304 stainless steel with a minimum sheet thickness of 0.6 mm, which gives them excellent rigidity, mechanical strength and dimensional stability under intensive daily use. Their open design, without lid and with angled edges, allows convenient stacking of several units, optimising space in cabinets, dressing trolleys and work surfaces, while facilitating direct access to instruments during the procedure. As reusable metal containers, they withstand the usual reprocessing cycles of the facility: cleaning, disinfection and sterilisation in an autoclave at 121 °C. AISI 304 steel is resistant to corrosion and to most healthcare chemicals, ensuring a long service life even with intensive use and contributing to infection control.
3. Technical Specifications
AISI 304 stainless steel container (holloware) with a minimum sheet thickness of 0.6 mm. Open instrument tray, without lid, with angled edges. Autoclavable at 121 °C.
Available references
| Reference | Size | Sales unit | Details |
|---|---|---|---|
| GM26597 | 380X304X50 mm | 1 pc | |
| GM26598 | 440X320X64 mm | 1 pc | |
| GM26603 | 306X196X50 mm | 1 pc | Autoclavable at 121°C · AISI 304 · Without cover |
| GM26604 | 355X254X50 mm | 1 pc | Autoclavable at 121°C · AISI 304 · Without cover |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
| CND | V0402 |
| GMDN | 12143 |
4. Equivalences and Cross-References
This range of trays corresponds to factory references Ref. 26597, 26598, 26603 and 26604 (SKUs Cahnos GM26597, GM26598, GM26603 and GM26604), verified in the official catalogue Product_DB.csv. No reliable source has been found with a manufacturer-validated equivalence table declaring these trays as interchangeable 1:1 with references from other manufacturers; any substitution in technical specifications or tenders must be validated field by field (AISI 304 material, sheet thickness of 0.6 mm, external dimensions and accepted sterilisation cycle at 121 °C) against the issuing manufacturer’s data sheet. At category level, this type of open stainless steel instrument tray is marketed under brands such as Surtex Instruments, Industrias Gonzalo or TALEXCO, whose models are considered comparable by category (not interchangeable 1:1) and must be confirmed with our technical-commercial department. Within Cahnos’s own catalogue, the same family without lid includes the more compact formats GM26599 (223 x 126 x 45 mm), GM26601 (210 x 160 x 25 mm) and GM26602 (264 x 172 x 47 mm), as well as the lidded versions GM26605, GM26606, GM26607, GM26608 and GM26609, and the perforated versions GM26646 and GM26647 that favour steam circulation during sterilisation.
5. Selection tips and variants of interest
Select reference GM26597 (380 x 304 x 50 mm) or GM26598 (440 x 320 x 64 mm) when you need a large work surface for surgical tables, dressing fields or high-volume instrument boxes; choose GM26603 (306 x 196 x 50 mm) or GM26604 (355 x 254 x 50 mm) for intermediate formats for everyday use. Always check the useful dimensions against the size of your instruments and the space available in cabinets, trolleys and autoclaves. If you prefer to protect the instruments during storage and transport, consider the lidded versions GM26605 to GM26609; if you are looking for better steam circulation during sterilisation, the perforated versions GM26646 and GM26647. Keep the tray dry and place clean instruments on it to avoid moisture build-up. For institutional orders, tenders or special volume conditions, contact the technical-commercial team at Cahnos. For large orders you can request a quote.







Reviews
There are no reviews yet.