We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable Non-Sterile Absorbent Viscose Field Sheets (TNT) 20 g/m² with Adhesive and Fenestration Ø 8 cm – 50 x 40 cm | Ref. 10402

117,43 €

Disposable non-sterile field sheets made of absorbent viscose non-woven fabric (TNT) of 20 g/m², with adhesive strip and central fenestration of 8 cm diameter. Compact and manageable 50 x 40 cm format, ideal for keeping the work area clean, dry and perfectly delimited in non-invasive procedures, wound dressings, punctures, examinations and medical preparation in hospitals, clinics, practices and day hospitals. The cellulosic fibre retains liquids quickly and the adhesive fixation prevents displacement without the need for forceps or auxiliary staff. Single-use product, not suitable for re-sterilisation: eliminates the risk of cross-contamination and simplifies healthcare waste management. Reference Cahnos 10402; B2B volume conditions under quotation from our technical-commercial team.

International shipping. Import duties and taxes are payable by the recipient.

Reference
10402

Description

1. Commercial Introduction

The Non-sterile Disposable Absorbent Viscose Field Drapes (Ref. 10402) are the practical and economical solution for maintaining a clean, dry and perfectly delimited working field in medical procedures that do not require sterility. Their non-woven fabric (TNT) of viscose fibre of 20 g/m² combines excellent liquid retention capacity with a soft and comfortable feel, protecting the patient, the healthcare professional and the working surface throughout the intervention.

The compact 50 x 40 cm format, the central 8 cm fenestration and the adhesive strip make it a manageable and reliable cover for wound dressings, punctures, catheterisations, examinations, ultrasounds, minor outpatient surgery and medical preparation tasks in hospitals, clinics, practices and health centres.

2. Technical explanation of the product and procedure

This drape belongs to the family of single-use disposable surgical coverings. It is made of non-woven fabric (TNT) of viscose fibre, a cellulosic material with a soft feel and high fluid retention capacity that absorbs moisture from the working field and prevents it from passing through to the bed linen or the underlying surface, keeping the intervention area dry and free of contaminants during the procedure.

The central fenestration of 8 cm in diameter precisely delimits the working point and allows direct access to the area to be treated while the rest of the surface remains covered and protected. The adhesive strip fixes the drape to the skin or surface without the need for forceps or auxiliary staff, preventing accidental displacement during the procedure.

As it is a non-sterile and disposable product, it is intended for procedures with a low risk of contamination: wound dressings, punctures, catheterisations, minor outpatient surgery, examinations, ultrasounds and medical preparation. It must be disposed of after each use in accordance with the centre’s healthcare waste management protocol and is not suitable for re-sterilisation or reuse.

3. Technical Specifications

Characteristic Specification
Reference (SKU) 10402
Product type Non-sterile disposable field drapes with adhesive and fenestration
Material Non-woven fabric (TNT) of absorbent viscose
Grammage 20 g/m²
Measurements 50 x 40 cm
Fenestration diameter 8 cm
Condition Non-sterile
Fixation Adhesive strip on skin or surface, without the need for forceps
Use Single-use (disposable), not suitable for re-sterilisation
Application Wound dressings, punctures, catheterisations, minor surgery, examinations, ultrasounds, medical preparation
Presentation Bags or boxes depending on sales format; check units per pack
Scope of use Clinical, outpatient and hospital

Technical note: the grammage of 20 g/m² and the fenestration diameter of 8 cm correspond to the declared product specification; do not extend these ranges without technical confirmation from the manufacturer. In the category of surgical fields, it is common for manufacturers to declare conformity with the standard EN 13795 (barrier requirements and performance of surgical fields, corresponding part); verify the declaration of conformity of the supplied batch before use in protocols that require it.

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer for this generic non-woven fabric reference: it is a white-label product under our own code Cahnos (Ref. 10402), so any substitution in tenders or protocols must be confirmed in advance with our technical department.

Within the Cahnos catalogue (same family of disposable surgical covering, same grammage of 20 g/m² and same fenestration diameter of 8 cm):

Reference Description Equivalence level
Ref. 10402 Non-sterile absorbent viscose with adhesive and fenestra, 50 x 40 cm, Ø 8 cm, 20 g/m² Product of this data sheet
Ref. 10602 Non-sterile absorbent viscose fenestrated with adhesive, 50 x 40 cm, Ø 8 cm, 20 g/m² Format equivalent: same measurements, material and fenestration (confirm with technical department)
Ref. 10502 / 10702 Sterile absorbent viscose with adhesive and fenestration, 50 x 40 cm, Ø 8 cm, 20 g/m² Comparable by category: same dimensions and material; sterility differs
Ref. 10604 Non-sterile absorbent viscose fenestrated with adhesive, 50 x 80 cm, Ø 8 cm, 20 g/m² Comparable by category: same material and fenestration, intermediate coverage
Ref. 10431 Non-sterile absorbent viscose with adhesive and fenestration, 75 x 100 cm, Ø 8 cm, 20 g/m² Comparable by category: same material and fenestration, wide coverage
Ref. 11602 Plasticised viscose, non-sterile, fenestrated with adhesive, 50 x 40 cm, Ø 8 cm Comparable by category: same format and fenestra; material changes (plasticised vs absorbent)

Market references (comparable at category level, not interchangeable 1:1): fenestrated surgical drapes with adhesive from brands such as 3M/Solventum Steri-Drape (range of incision drapes with adhesive film), Naturdrape from Lohmann & Rauscher (fenestrated drapes of 2-3 layers with polyethylene film), BOENMED, Medline and Hartmann cover the same general clinical indication, but differ in sterility, grammage (fabrics usually of 28-56 g/m² compared to 20 g/m²), layer composition (polypropylene laminated with polyethylene versus absorbent viscose) and fenestration geometry. They cannot be treated as exact equivalents: verify material, grammage, dimensions, sterility, single-use and regulatory classification before substituting. The specific codes of these brands are pending confirmation with the manufacturer or authorised distributor; consult the technical department of Cahnos before using them in tenders.

5. Selection tips and variants of interest

  • Sterility: select this non-sterile version (Ref. 10402) when the procedure does not require a sterile field (wound dressings, catheterisations, punctures, examinations or ultrasounds); for surgery or sterile technique, request the sterile version of the same family and measurements (Ref. 10502 or 10702).
  • Format: 50 x 40 cm is the most compact and manageable option, recommended for localised anatomical areas and short-duration procedures; if you need more surface area, consider the 50 x 80 cm (Ref. 10604) or 75 x 100 cm (Ref. 10431) formats, with the same material and the same fenestration diameter.
  • Fenestration: the diameter specified by the manufacturer is 8 cm; do not extrapolate this data to other diameters without technical confirmation. If your technique requires a larger opening, consult the Ø 10 cm variants of the viscose family with our team.
  • Material: the absorbent viscose version prioritises liquid retention and softness; if you also need a superior barrier against splashes, consider the plasticised version of the same sizes (Ref. 11602).
  • Pre-substitution verification: when comparing with other brands, check one by one the material, grammage, dimensions, sterility, single-use and regulatory classification before incorporating an alternative product into your protocol.
  • Management: single-use product; dispose of after each procedure in accordance with the centre’s healthcare waste management protocol. Not suitable for re-sterilisation or reuse.
  • B2B purchasing: for high-volume orders, continuous supply contracts or group purchasing organisation budgets, contact the technical-commercial team at Cahnos for special conditions and units per pack.

Additional information

Reference

10402

Product type

Non-sterile disposable field drapes with adhesive and fenestration

Material

Non-woven fabric (TNT) of absorbent viscose

Measurements

50 x 40 cm

Fenestration diameter

8 cm

Fixation system

Adhesive strip on skin or surface, without forceps

Use

Single-use (disposable), not suitable for re-sterilisation

Application

Wound dressings, punctures, catheterisations, minor surgery, examinations, ultrasounds, medical preparation

Presentation

Bags or boxes depending on sales format

Scope of use

Clinical, outpatient and hospital

Reference standard

EN 13795 (verify the batch's declaration of conformity)

Gramaje

20 g/m²

Esterilidad

Non-sterile

Reviews

There are no reviews yet.

Be the first to review “Disposable Non-Sterile Absorbent Viscose Field Sheets (TNT) 20 g/m² with Adhesive and Fenestration Ø 8 cm – 50 x 40 cm | Ref. 10402”

Your email address will not be published. Required fields are marked *