Description
1. Commercial Introduction
The OPS™ Essential pacemaker drape from Medline is the sterile surgical cover solution designed for cardiovascular procedures and, in particular, for pacemaker implantation and replacement, thanks to its adapted fenestration. Designed and tested alongside operating theatre professionals, this single-use individual drape allows the operative field to be delimited quickly and safely, keeping the patient protected and the care team fully at ease throughout the procedure.
It belongs to the economical OPS™ Essential collection, a family of surgical coverings that combines high resistance, adaptability and reliable barrier performance in the operating block, at an optimised cost for interventional cardiology, haemodynamics and electrophysiology units. This product is sold on quotation: contact the technical-commercial department of Cahnos for availability, lead times and conditions.
2. Technical Explanation
This drape is specifically designed for pacemaker procedures, in which the operative field has a significant presence of fluids. With dimensions of 200 x 280 cm, the drape incorporates a 15 x 15 cm fenestration that precisely delimits the working area while keeping the rest of the patient protected, and the adhesive strip facilitates secure fixation of the field over the incision area.
The OPS™ Essential collection is manufactured from a bilaminate material composed of non-woven polypropylene and a polyethylene film, a combination that offers an exceptional microbial barrier and optimal fluid control: the drape surface is absorbent and impermeable across its entire extent. As a sterile single-use product, it is disposed of after each procedure in accordance with the centre’s healthcare waste management protocol, reducing the risk of cross-contamination and optimising preparation times. Medline surgical drapes and equipment have been developed and tested by operating theatre professionals and fully comply with standard EN13795 for surgical drapes and gowns. The intuitive labelling system shows informative product images and detailed specifications.
3. Technical specifications and tables
Available references
| Reference | Dimensions | Units per box |
|---|---|---|
| ES10020CE | 200 x 280 CM | 24 |
Material characteristics and presentation
| Characteristic | Specification |
|---|---|
| Brand / Range | Medline – OPS™ Essential |
| SKU Cahnos | MDLP-QG46O |
| Medline family | P-QG46O |
| Order reference | ES10020CE |
| Product type | Individual drape (Individual Drape) |
| Measurements | 200 x 280 cm |
| Fenestration | 15 x 15 cm |
| Main material | Polypropylene/polyethylene bilaminate |
| Main material characteristic | Absorbent and impermeable |
| Adhesive | Yes |
| Incisional film (Incise Film) | No |
| Colour of the surgical drape | Blue |
| Packaging presentation | High performance (High Performance) |
| Single-use | Yes |
| Sterile | Yes |
| Compliance | EN13795 |
4. Equivalences and Cross-References
This drape is marketed under the manufacturer references MDLP-QG46O (SKU Cahnos), P-QG46O (Medline family code) and ES10020CE (order reference, 24 units per box); the three codes identify the same drape and can be used interchangeably for orders and technical enquiries. In the Medline catalogue it is classified under Surgical Covering > Surgical Drapes and Sheets > Cardiovascular Drapes.
Within the cardiovascular surgical covering range from Medline available at Cahnos, there are other configurations comparable by indication but not interchangeable 1:1, such as the reinforced Eclipse® pacemaker drape (DYNJPE4107), made of spunlace polyester/cellulose fabric with double fenestration and a catheter pouch; the reinforced OPS™ Essential pacemaker drape (ES9409CE), 262 x 360 cm with a 12 x 15 cm fenestration and transparent panels; or the reinforced OPS™ Ultimate pacemaker pack (TB9408CE), made of trilaminate fabric with a 15 x 15 cm fenestration. No validated 1:1 equivalence table is available against other brands on the market; before replacing this drape with one from another manufacturer, always validate dimensions, fenestration size, material, degree of reinforcement and sterile presentation against the corresponding technical data sheet. Consult the technical-commercial department of Cahnos to validate specific equivalents.
5. Selection tips and variants of interest
Main indication: select this drape for pacemaker implantation or replacement procedures, as well as for electrophysiology and interventional cardiology, when you need an economical individual covering with a 15 x 15 cm fenestration and adhesive.
Measurement verification: check that the 200 x 280 cm drape and the fenestration size fit your usual technique and the intended table or patient size. If your service requires a larger field or additional reinforcement, consider the reinforced OPS™ Essential pacemaker drape (ES9409CE); if you need a three-layer barrier, the OPS™ Ultimate range (TB9408CE).
Consumption and stock management: as this is a sterile single-use product in boxes of 24 units, plan replenishment according to your surgical schedule, rotate stock according to the packaging expiry date and verify the integrity of the packaging before each use.
Institutional orders and tenders: for complete supplies, tenders or continuous supply contracts, contact the technical-commercial department of Cahnos indicating the exact reference (ES10020CE / MDLP-QG46O) and the estimated volume; this product is sold on quotation.