Description
1. Commercial Introduction
The Eclipse® turban-style drape set for ENT with Mayo table cover from Medline is the sterile, single-use surgical covering solution your operating theatre needs for ENT and head and neck surgery procedures. A complete, ready-to-deploy set that brings together all the elements needed to set up a defined, safe and efficient surgical field, ensuring optimal protection for both the patient and the healthcare team. It belongs to the renowned Eclipse® collection, developed and tested by operating theatre professionals across Europe. This product is sold on quotation: please request terms, lead times and volumes from our technical-commercial team.
2. Technical explanation of the equipment
This set is designed for isolation of the surgical field in ENT surgeries. The reinforced spunlace sheet with opening (196 x 279 cm) incorporates an adhesive opening of 6 x 64 cm that is fixed over the working area, precisely delimiting the field and preventing accidental displacement during the procedure. The spunlace head sheet (82.5 x 107 cm) adapts around the patient’s skull in a turban format, maintaining mobility during the procedure. The set is completed by the Mayo table cover (80 x 142 cm), which keeps sterile instruments organised within the surgeon’s reach, and the table cover (140 x 190 cm), which protects work surfaces.
To achieve exceptional adaptability and softness, the Eclipse® drape and sheet collection from Medline uses a non-woven fabric composed of polyester and cellulose fibres. Its repellent and breathable characteristics favour patient comfort by preventing heat build-up, while maintaining an effective barrier against fluids. All components are sterile and single-use, eliminate the risk of cross-contamination and fully comply with standard EN13795 for surgical drapes and towels. Medline’s intuitive labelling system shows informative images and detailed specifications for quick and safe identification in the operating theatre.
3. Technical specifications and tables
Equipment contents
| Component | Quantity | Dimensions / Features |
|---|---|---|
| Reinforced spunlace sheet with opening | 1 | 196 x 279 cm; adhesive opening 6 x 64 cm |
| Spunlace head sheet | 1 | 82.5 x 107 cm |
| Mayo table cover | 1 | 80 x 142 cm |
| Table cover | 1 | 140 x 190 cm |
Available references
| Reference | Set version | Units per box |
|---|---|---|
| 9192CEA | A | 8 |
Manufacturer’s specifications
| Characteristic | Specification |
|---|---|
| Brand / Manufacturer | Medline (Medline International – medline.eu) |
| SKU Cahnos | MDLP-JP76D |
| Medline family | P-JP76D |
| Manufacturer references | MDLP-JP76D, P-JP76D, 9192CEA |
| Product type | Surgical draping set (Drapping Pack) |
| Main material | Cellulose/polyester spunlace (non-woven fabric) |
| Main material characteristic | Repellent and breathable |
| Adhesive | Yes |
| Fenestration | No |
| Colour of the surgical drape | Blue |
| Packaging | High performance (High Performance) |
| Single-use | Yes |
| Sterile | Yes |
| Compliance | EN13795 |
| Medline category | Surgical Drapes > Surgical Drape Sets > Sterile Neck Sets |
4. Equivalences and Cross-References
This set is marketed on Cahnos under SKU MDLP-JP76D, corresponding to the Medline P-JP76D family and the manufacturer’s catalogue reference 9192CEA (version A, presentation of 8 sets per box). The three codes designate the same product and can be used interchangeably for orders and technical enquiries.
Within the Medline catalogue available on Cahnos, other surgical covering configurations share the same ENT indication and compliance with standard EN13795, comparable by specialty but not interchangeable 1:1:
| Reference | Configuration | Related to this product |
|---|---|---|
| 9193CEA / MDLP-XT23H | Eclipse® turban-style drape set for ENT (without Mayo table cover) | Same Eclipse® family, set format without Mayo table (not interchangeable 1:1) |
| 9556CEA | Eclipse® turban-shaped drape for ENT, 82 x 107 cm | Same family, individual drape format (not interchangeable 1:1) |
| 29232CEA / MDLP-ML14O | Eclipse® fenestrated drape set for ENT (adhesive fenestration of 6 cm) | Same Eclipse® family, fenestrated configuration (not interchangeable 1:1) |
| TB9192CE / MDLP-MU64F | Turban-style set for ENT OPS™ Ultimate, absorbent and impermeable trilaminate | Comparable by indication, Ultimate range (not interchangeable 1:1) |
No 1:1 equivalence table validated by the manufacturer is available against sets from other suppliers (e.g. HARTMANN, Mölnlycke or Cardinal Health); any substitution in specifications or tenders must be verified field by field (pack contents, dimensions, adhesive, fenestration, barrier level and presentation). Consult the technical-commercial department at Cahnos to validate specific equivalences.
5. Selection tips and variants of interest
Select this set when the planned procedure is ENT or head and neck surgery and requires the additional coverage provided by the Mayo table cover (80 x 142 cm), ideal for keeping sterile instruments organised during the procedure. Its sheet with adhesive opening of 6 x 64 cm ensures precise and stable delimitation of the field, and the turban-style design maintains mobility of the patient’s head.
If your protocol does not require the Mayo table cover, consider the Eclipse® turban-style drape set (ref. 9193CEA); if you need a fenestrated configuration with more precise access, the Eclipse® fenestrated drape set (ref. 29232CEA) is available; and if you only require the individual head drape, the turban-style sheet 9556CEA (82 x 107 cm) is the most suitable option. For higher barrier performance with trilaminate fabric, consider the OPS™ Ultimate turban-style set (ref. TB9192CE).
As this is a sterile single-use product, plan replenishment according to your surgical schedule and rotate stock on a first-in, first-out (FIFO) basis. The box presentation of 8 sets (version A, ref. 9192CEA) facilitates consumption forecasting in ENT departments and surgical blocks. For volume orders, supply contracts or tenders, contact the technical-commercial team at Cahnos quoting the exact reference (9192CEA / MDLP-JP76D).






Reviews
There are no reviews yet.