Description
1. Commercial Introduction
We present the double-layer non-woven (TNT) surgical drape in 100×100 cm format, a disposable and sterile covering solution designed to guarantee maximum safety and hygiene in the operating theatre. Made in Italy, it combines absorbency and impermeability to protect both the patient and the surgical team during the procedure. Its presentation in a box of 120 units makes it an efficient and cost-effective option for hospitals, clinics and outpatient centres with high material turnover.
2. Technical Explanation
This surgical drape is made from a double-layer non-woven material (bi-layer) that combines an absorbent side, which retains moisture from the treated area, and an impermeable barrier that prevents the passage of liquids to the patient or the work surface. This construction provides effective protection against fluid transmission, keeping the operative field dry, stable and free from cross-contamination throughout the procedure.
It is a single-use product, supplied sterile and ready to open following aseptic technique. In addition, it is manufactured without natural rubber or latex, which reduces the risk of allergic reactions in sensitised patients and healthcare personnel. It is classified as a class IIa medical device and its use is recommended as a surgical barrier in general surgery procedures and specialties requiring a standard covering surface.
3. Technical Specifications
Sterile, disposable and single-use surgical drape for covering and isolating the operative field.
| Characteristic | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 23583 (SKU Cahnos: GM23583) |
| Size | 100 x 100 cm |
| Material | Double-layer non-woven (TNT), absorbent and impermeable |
| Use | Single-use (disposable) |
| Sterility | Sterile |
| Composition | Without natural rubber or latex |
| Sales unit | Box of 120 units |
| Origin | Made in Italy |
Product data
| Sales unit | Box of 120 units |
|---|---|
| Device type | Medical device |
| Device class | II A |
| CND | T020199 |
| GMDN | 35531 |
| EAN | 8023279235838 |
Available references in the range
| Reference | Size | Sales unit |
|---|---|---|
| GM23580 | 50×50 cm | Box of 350 units |
| GM23581 | 45×75 cm | Box of 320 units |
| GM23582 | 75×90 cm | Box of 170 units |
| GM23583 | 100×100 cm | Box of 120 units |
| GM23584 | 100×150 cm | Box of 80 units |
| GM23585 | 150×150 cm | Box of 70 units |
| GM23586 | 150×200 cm | Box of 50 units |
| GM23587 | 150×240 cm | Box of 40 units |
| GM23588 | 200×200 cm | Box of 40 units |
| GM23589 | 200×250 cm | Box of 30 units |
4. Equivalences and Cross-References
Reference 23583 corresponds to the manufacturer’s official code for this 100×100 cm double-layer non-woven surgical drape, according to the manufacturer’s product database (Product_DB.csv). This drape belongs to the family of sterile double-layer non-woven surgical drapes (refs. 23580-23589), which share the same material, the CND classification T020199 and the GMDN 35531, differing only in size and the number of pieces per box.
A 1:1 equivalence with other manufacturers has not been verified for this exact reference; it is recommended to validate any substitution in tenders or protocols with the technical department before deciding on a change of supplier.
5. Selection tips and variants of interest
Select the drape size according to the extent of the surgical field and the type of procedure. The 100×100 cm format is a versatile and balanced option, suitable for medium-sized surgical fields and as a standard complementary covering drape. For smaller fields or auxiliary tables, the 45×75 and 50×50 cm sizes are more practical, while the 75×90, 100×150 and 150×150 cm formats adapt to larger surgeries; for large-scale procedures, sizes of 150×200, 150×240, 200×200 and 200×250 cm are available.
If the procedure requires isolating the incision area through an opening, consult the series of fenestrated drapes with central adhesive opening (refs. GM23620 to GM23626), as well as the individually packaged impermeable double-layer non-woven drapes (series GM23600). As this is a sterile single-use product, always check the integrity of the packaging and the expiry date before each use. For large orders you can request a quote: contact the technical-commercial team at Cahnos for B2B conditions, volumes and delivery times.





Reviews