Description
1. Commercial Introduction
The disposable sterile fenestrated surgical drapes made of non-woven plasticised viscose fabric (Ref. 11331) are the professional solution for keeping a clean, dry and perfectly defined operating field during medical or surgical procedures. Made of plasticised viscose of 20 g/m², they combine excellent absorbency with an effective barrier against liquids, protecting the patient, the healthcare team and the work surface.
With a wide coverage of 75 x 100 cm and a circular fenestra of 10 cm in diameter, this drape allows precise and controlled surgical access without compromising the sterility of the rest of the field. It is a single-use product, ready to use, designed for hospitals, clinics, operating theatres and ambulatory surgery centres where asepsis and efficiency allow no concessions.
2. Technical Explanation
This drape belongs to the family of disposable single-use surgical coverings. It is made of non-woven fabric (TNT) of viscose with a plasticised finish, which combines the softness and absorbency of viscose fibre with the partial impermeability provided by the plastic coating. The result is a light, resistant material with good performance as a barrier against liquids and particles.
The central fenestra of Ø 10 cm precisely delimits the work area and allows direct access to the intervention point, while the rest of the surface remains covered and isolated. As this is a version without adhesive, fixation is achieved using field forceps or by placing it directly on the patient, according to the team’s preference. The product is removed from its packaging following aseptic technique and disposed of after each use: it does not allow reuse or re-sterilisation.
3. Technical specifications and reference tables
| Reference (SKU) | 11331 |
| Product type | Disposable sterile fenestrated sheet / field drape |
| Material | Non-woven fabric (TNT) of plasticised viscose, absorbent |
| Grammage | 20 g/m² |
| Size | 75 cm x 100 cm |
| Fenestration | Diameter of 10 cm (circular) |
| Condition | Sterile |
| Fixation | Without adhesive |
| Use | Single-use (disposable, not re-sterilisable) |
| Advantages | High absorbency, sterile protection, precise access, wide coverage |
| Application | Operating theatre, hospital, clinic: minor surgery, wound dressings, punctures, catheterisation, examinations |
Technical note: in the category of surgical drapes, it is common for manufacturers to declare conformity with standard EN 13795 (barrier requirements and performance of surgical drapes). Verify the declaration of conformity of the supplied batch before use in protocols that require it.
4. Equivalences and Cross-References
Ref. 11331 corresponds to a Cahnos own code within the family of plasticised viscose surgical coverings. There is no manufacturer-validated equivalence table cross-referencing this reference with specific codes from other suppliers; any substitution in tenders or protocols must be confirmed with the Cahnos technical department. For guidance, the following variants of the same family are listed in the Cahnos catalogue:
| Reference | Description | Equivalence level |
| 11331 | Sterile fenestrated plasticised viscose, 75 x 100 cm, Ø 10 cm, without adhesive | This product |
| 11231 | Non-sterile plastic-coated viscose fenestrated, 75 x 100 cm, Ø 10 cm, without adhesive | Comparable by category: same material, dimensions and fenestration; only sterility differs |
| 11731 | Sterile plastic-coated viscose fenestrated with adhesive, 75 x 100 cm, Ø 8 cm | Same material and sterility; adds adhesive strip and changes fenestration diameter (8 cm) |
| 10731 | Sterile fenestrated absorbent viscose with adhesive, 75 x 100 cm, Ø 8 cm | Comparable by category: same dimensions and sterility; the material changes (absorbent vs. plasticised) and adhesive is added |
At category level (not interchangeable 1:1), this type of fenestrated surgical field drape is present in the ranges of major operating theatre material manufacturers such as 3M/Solventum Steri-Drape, Mölnlycke Health Care, Hartmann, Medline, L&R Raucodrape, BOENMED or Naturdrape. These brands cover the same general clinical indication, but differ in grammage (fabrics usually 40–56 g/m² vs. 20 g/m²), layer composition (polypropylene laminated with polyethylene vs. plasticised viscose), fenestra geometry and regulatory classification. They should not be treated as exact equivalents: check material, grammage, dimensions, fenestra diameter, single-use and regulations before substituting. The specific codes of these brands are pending confirmation with the manufacturer or authorised distributor.
5. Selection tips and variants of interest
- Fenestra diameter: the manufacturer’s Ø 10 cm fenestra offers wide and focused access. If the technique requires a smaller opening or adhesive fixation, consider the Ø 8 cm variant with adhesive (Ref. 11731). Do not extrapolate this data to other diameters without technical confirmation.
- Sterile vs. non-sterile: use this sterile version (Ref. 11331) for surgery or sterile technique; if the procedure does not require sterility (wound dressings, catheterisations, examinations), the same family in non-sterile version is available in the same format (Ref. 11231).
- Material: the plasticised version provides a greater barrier against liquids; if pure absorbency is prioritised, consider the sterile absorbent viscose family in the same format (Ref. 10731).
- How to place the field: as this is a version without adhesive, secure the drape with field forceps or place it directly on the patient, ensuring the fenestra is centred over the surgical site.
- Single-use: dispose of after each procedure in accordance with the centre’s healthcare waste management protocol; not suitable for re-sterilisation or reuse. Check the integrity of the sterile packaging and the expiry date before each use.
- B2B purchasing: for high-volume orders, closed-box presentation or group purchasing organisation conditions, consult your Cahnos sales representative for special conditions and units per package.





Reviews