Description
1. Commercial Introduction
The Eclipse® reinforced adhesive fenestrated drape from Medline is the reference choice for covering the surgical field in general surgery procedures. Developed and tested alongside operating theatre professionals, it offers a reliable sterile barrier, quick and easy placement, and great security of the operating field throughout the procedure. Its integrated adhesive seals the work area onto the skin without the need for forceps, reducing the risk of cross-contamination and speeding up preparation of the surgical block.
This product is sold under budget: contact our technical-commercial team at Cahnos for B2B terms, lead times and availability.
2. Technical Explanation
This individual drape (Individual Drape) belongs to the Eclipse® collection from Medline, characterised by a spunlace nonwoven fabric composed of polyester and cellulose fibres that combines exceptional adaptability and softness. Its main material characteristic is repellent and breathable: it effectively repels fluids while maintaining adequate breathability that prevents heat build-up and provides patient comfort during prolonged procedures.
It incorporates a 10 x 15 cm adhesive fenestration that fixes directly onto the skin around the work area, delimiting the field without accidental displacement, and a 30 x 33 cm absorbent reinforcement that controls fluids generated in the surgical area. Being a sterile and single-use product, it eliminates the risk of cross-contamination and facilitates healthcare waste management in accordance with the centre’s protocol. It fully complies with the European standard EN13795 for surgical drapes and gowns, and its intuitive labelling system shows informative images and detailed specifications for quick and safe identification.
3. Technical specifications and available references
Available references
| Reference | Dimensions | Units per box |
|---|---|---|
| DYJPEFDSEC | 102 x 157 CM | 20 |
Manufacturer’s specifications
| Characteristic | Specification |
|---|---|
| Brand / Manufacturer | Medline (Medline International – medline.eu) |
| SKU Cahnos | MDLP-QA73I |
| Medline family | P-QA73I |
| Manufacturer references | MDLP-QA73I, P-QA73I, DYJPEFDSEC |
| Product type | Individual drape (Individual Drape) |
| Main material | Cellulose/polyester spunlace (non-woven fabric) |
| Material characteristic | Repellent and breathable |
| Measurements | 102 x 157 cm |
| Fenestration | Adhesive fenestration 10 x 15 cm |
| Reinforced area | Absorbent reinforcement 30 x 33 cm |
| Adhesive | Yes |
| Colour of the surgical drape | Blue |
| Packaging | High performance (High Performance) |
| Sterility | Yes (sterile) |
| Use | Single-use |
| Compliance | EN13795 |
| Medline category | Surgical Cover > Surgical Sheets and Drapes > General Surgery |
4. Equivalences and Cross-References
This product is marketed in Cahnos under SKU MDLP-QA73I, corresponding to the Medline family P-QA73I and the manufacturer’s catalogue reference DYJPEFDSEC (presentation of 20 units per box). The three codes designate the same product and can be used interchangeably for orders and technical enquiries.
Within the Eclipse® range from Medline available at Cahnos, other individual surgical cover drapes share the cellulose/polyester spunlace fabric and compliance with standard EN13795, comparable by category but not interchangeable 1:1:
| Reference | Configuration | Related to this product |
|---|---|---|
| DYNJPE8301 / MDLP-DT94K | Eclipse® U-shaped reinforced drape with adhesive, 196 x 274 cm, fenestration 15 x 102 cm | Same Eclipse® family, larger coverage (not interchangeable 1:1) |
| 29670CEA / MDLP-RI62R | Eclipse® reinforced fenestrated drape for ENT, 150 x 196 cm, adhesive fenestration 6 cm | Same Eclipse® family, ENT indication (not interchangeable 1:1) |
| 29232CEA | Eclipse® fenestrated drape set for ENT | Same Eclipse® family, set format (not interchangeable 1:1) |
There is no 1:1 equivalence table validated by the manufacturer against drapes from other suppliers (e.g. Hartmann, Mölnlycke or Cardinal Health); any substitution in tenders or contracts must be verified field by field (dimensions, fenestration, adhesive, barrier level, sterility and presentation) before use. Consult the technical-commercial department at Cahnos to validate equivalences.
5. Selection tips and variants of interest
Select this individual drape when the procedure requires a 10 x 15 cm adhesive fenestration with a localised absorbent reinforcement that ensures fluid control in the work area, ideal for general surgery and delimited surgical fields. Its repellent and breathable spunlace material guarantees an effective barrier against liquids with full patient comfort.
If your protocol requires a larger coverage area or a U-shaped field for orthopaedics and traumatology, consider the Eclipse® U-shaped reinforced drape with adhesive (DYNJPE8301 / MDLP-DT94K). For ear, nose and throat indications with a 6 cm fenestration, we offer the Eclipse® reinforced fenestrated drape for ENT (29670CEA / MDLP-RI62R). If you need a complete set with drapes, tube support and towels, consider the Eclipse® fenestrated drape set for ENT (29232CEA).
As this is a sterile single-use product, plan replenishment according to the surgical schedule of your department and rotate stock on a first-in, first-out (FIFO) basis. The presentation in a box of 20 units (ref. DYJPEFDSEC) facilitates consumption forecasting for the surgical block. Budgetary product: request terms, lead times and availability from our technical-commercial team at Cahnos.