We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Sterile Surgical Fenestrated Drape with Adhesive – Absorbent Viscose Non-woven TNT 20 g/m², 75 x 100 cm, Fenestration Ø 8 cm | Ref. 10731

104,83 €

Sterile surgical fenestrated drape with adhesive, made of non-woven (TNT) absorbent viscose 20 g/m², in a wide format of 75 x 100 cm and a central fenestration of 8 cm diameter. Its cellulosic viscose fibre offers a high liquid retention capacity that keeps the operative area dry and delimited, while the adhesive band fixes the drape to the skin without the need for forceps, ensuring a stable sterile field throughout the procedure. Single-use and sterile presentation, ready to use in the operating theatre, major and minor surgery, advanced wound dressings, punctures, catheterisations and hospital examinations. Reference Cahnos 10731.

International shipping. Import duties and taxes are payable by the recipient.

Reference
10731

Description

1. Commercial Introduction

The Sterile Fenestrated Surgical Field Drape with Adhesive (Ref. 10731) is the reference disposable covering solution for keeping the operative field clean, dry and perfectly defined in procedures requiring sterility. Its non-woven (TNT) absorbent viscose fabric of 20 g/m² combines excellent liquid retention capacity with a soft and comfortable feel, protecting the patient, the healthcare team and the work surface throughout the intervention.

The wide format of 75 x 100 cm provides extensive coverage designed for major surgical interventions, with precise access through a central 8 cm fenestration and an adhesive band that fixes the drape to the skin without the need for forceps or assistants. A ready-to-use option that provides sterility, secure fixation and high functionality in hospitals, clinics and practices.

2. Technical explanation of the product and procedure

These drapes belong to the family of disposable single-use surgical covering. They are made of non-woven fabric (TNT) of viscose fibre, a cellulosic material with high absorption capacity that captures and retains fluids from the surgical field, keeping it dry and preventing cross-contamination between the treated area and the rest of the patient’s body.

The central fenestration of 8 cm diameter precisely delimits the work area and allows direct access to the intervention point, while the rest of the area remains covered and protected. The peripheral adhesive band fixes the drape to the skin or surface without the need for forceps or accessories, preventing accidental displacement and ensuring a stable seal of the sterile field throughout the procedure.

Being a sterile, disposable and single-use product, it is intended for operating theatre, surgery, sterile technique and hospital procedures where a sterile barrier is required: major and minor surgery, advanced wound dressings, punctures, catheterisations, explorations and minor ambulatory interventions. Its use eliminates the risk of cross-contamination and simplifies the management of healthcare waste in accordance with the centre’s protocol.

3. Technical Specifications

Product type Sterile disposable surgical drape sheet with adhesive and fenestration
Reference (SKU) 10731
Material Non-woven fabric (TNT) of absorbent viscose
Grammage 20 g/m²
Size 75 cm x 100 cm
Fenestration Diameter 8 cm
Condition Sterile
Fixation Adhesive strip for fixation on skin or surface, without forceps
Use Single-use (disposable), not suitable for re-sterilisation
Application Large surgical, hospital and clinical procedures: operating theatre, surgery, wound dressings, punctures, catheterisations, explorations
Advantages High absorption, secure fixation, sterile protection, precise access to the surgical area
Presentation Sterile individual packaging, closed box; consult units per pack

Technical note: in the category of surgical fields it is common for manufacturers to declare compliance with the standard EN 13795 (barrier requirements and performance of surgical fields); verify the declaration of conformity of the supplied batch before use in protocols that require it.

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer for this generic non-woven fabric reference: it is a white-label product under our own code Cahnos (Ref. 10731), so any substitution in tenders or protocols must be confirmed in advance with our technical department.

Within the Cahnos catalogue (same family of disposable surgical covering):

Reference Description Equivalence level
Ref. 10631 Non-sterile absorbent viscose fenestrated with adhesive, 75 x 100 cm, Ø 8 cm Format equivalent in non-sterile version: same dimensions, material and fenestration; sterility differs
Ref. 10531 Sterile absorbent viscose with adhesive, 75 x 100 cm, Ø 8 cm, 20 g/m² Direct equivalent of the same family and format (confirm availability with technical department)
Ref. 11731 Sterile plastic-coated viscose fenestrated with adhesive, 75 x 100 cm, Ø 8 cm Comparable by category: same dimensions and sterility; material changes (plastic-coated vs absorbent)
Ref. 11631 Non-sterile plastic-coated viscose fenestrated with adhesive, 75 x 100 cm, Ø 8 cm Comparable by category: same dimensions and fenestration; material and sterility change
Ref. 11704 Sterile plastic-coated viscose fenestrated with adhesive, 50 x 80 cm, Ø 8 cm Comparable by category: same material and sterility, smaller format
Ref. 10602 Absorbent viscose, non-sterile, fenestrated with adhesive, 50 x 40 cm, Ø 8 cm Comparable by category: same material and fenestration, other dimensions (smaller format)
Ref. 11231 Non-sterile plastic-coated viscose fenestrated, 75 x 100 cm, Ø 10 cm, without adhesive Comparable by category: different material, different fenestration diameter and without adhesive

Market references (comparable at category level, not interchangeable 1:1): fenestrated surgical fields with adhesive from brands such as BOENMED (fenestrated field with opening for incision), Naturdrape from Lohmann & Rauscher (fenestrated drapes of 2-3 layers with polyethylene film), 3M/Solventum Steri-Drape (adhesive fenestrated drape, e.g. reference 1020 of 40 x 40 cm, verified in 3M’s official catalogue) and L&R Raucodrape (fenestrated drapes) cover the same general clinical indication, but differ in sterility, grammage (fabrics of 40–56 g/m² versus 20 g/m²), layer composition (polypropylene laminated with polyethylene versus absorbent viscose) and fenestration geometry. They cannot be treated as exact equivalents: verify material, grammage, dimensions, sterility, single-use and regulatory classification before substituting. The specific codes of these brands are pending confirmation with the manufacturer or authorised distributor.

5. Selection tips and variants of interest

Sterility: for surgery or sterile technique use this version (Ref. 10731); if the procedure does not require a sterile field (wound dressings, catheterisations, punctures or explorations), the same family and sizes is available in non-sterile version (Ref. 10631), with a more competitive cost per unit.

Format: 75 x 100 cm offers wide coverage for extensive interventions; if you need more manoeuvrability in localised anatomical areas, consider the formats of 50 x 40 cm (Ref. 10602) or 50 x 80 cm (Ref. 10604) from the same material family.

Fenestration diameter: the one specified by the manufacturer is 8 cm; do not extrapolate this data to other diameters without technical confirmation. If your technique requires a larger opening, consult the non-adhesive variant of Ø 10 cm (Ref. 11231).

Material: the absorbent viscose version prioritises liquid retention and softness; if you also need a superior barrier against splashes, consider the plasticised viscose family of the same format (Ref. 11731).

Pre-substitution verification: when comparing with other brands, check one by one material, grammage, dimensions, sterility, single-use and regulatory classification before incorporating an alternative product into your protocol.

Single-use: dispose of after each procedure in accordance with the centre’s healthcare waste management protocol; not suitable for re-sterilisation or reuse. For high-volume orders, continuous supply contracts or group purchasing organisation budgets, contact your technical-commercial team at Cahnos.

Additional information

Product type

Sterile disposable surgical drape sheet with adhesive and fenestration

Reference

10731

Material

Non-woven fabric (TNT) of absorbent viscose

Measurements

75 cm x 100 cm

Fenestration

8 cm diameter

Condition

Sterile

Fixation system

Adhesive strip, without the need for forceps

Use

Single-use (disposable), not suitable for re-sterilisation

Application

Surgical, hospital and clinical procedures

Presentation

Sterile individual packaging

Regulatory standard

Usual compliance with EN 13795 (verify batch declaration)

Gramaje

20 g/m²

Reviews

There are no reviews yet.

Be the first to review “Sterile Surgical Fenestrated Drape with Adhesive – Absorbent Viscose Non-woven TNT 20 g/m², 75 x 100 cm, Fenestration Ø 8 cm | Ref. 10731”

Your email address will not be published. Required fields are marked *