Description
1. Commercial Introduction
The Sterile Fenestrated Surgical Drape Sheet of Absorbent Viscose (Ref. 10331) is the reference disposable cover solution for keeping the operating field clean, dry and perfectly delimited in procedures requiring sterility. Its non-woven fabric (TNT) of 20 g/m² viscose fibre combines excellent liquid retention capacity with a soft, comfortable feel, protecting the patient, the healthcare team and the work surface throughout the intervention.
The wide 75 x 100 cm format provides extensive coverage designed for major surgical interventions, with precise access through a central fenestra of 10 cm diameter. A ready-to-use option that delivers sterility, high absorption and functionality in hospitals, clinics, operating theatres and ambulatory surgery centres.
2. Technical explanation of the product and procedure
This drape belongs to the single-use disposable surgical cover family. It is manufactured from non-woven fabric (TNT) of viscose fibre, a cellulosic material with high absorption capacity that captures and retains fluids from the surgical field, keeping it dry and preventing cross-contamination between the treated area and the rest of the patient’s body.
The central fenestra of 10 cm diameter precisely delimits the work area and allows direct access to the intervention point, while the rest of the surface remains covered and isolated. As a sterile, disposable, single-use product, it is intended for the operating theatre, surgery, sterile technique and hospital procedures requiring a sterile barrier: major and minor surgery, advanced wound dressings, punctures, catheterisation, examinations and minor ambulatory interventions. Its use eliminates the risk of cross-contamination and simplifies healthcare waste management in accordance with the centre’s protocol.
3. Technical Specifications
| Characteristic | Specification |
| Reference (SKU) | 10331 |
| Product type | Disposable sterile fenestrated sheet / field drape |
| Material | Non-woven fabric (TNT) of absorbent viscose |
| Grammage | 20 g/m² |
| Size | 75 cm x 100 cm |
| Fenestration | Diameter of 10 cm (circular) |
| Condition | Sterile |
| Use | Single-use (disposable), not suitable for re-sterilisation |
| Application | Sterile surgical procedures: operating theatre, major and minor surgery, advanced wound dressings, punctures, catheterisation, examinations |
| Advantages | High absorption, wide coverage, precise access, sterile protection |
| Presentation | Sterile individual packaging, closed box; consult units per pack |
Technical note: in the surgical drape category, manufacturers commonly declare conformity with standard EN 13795 (barrier requirements and performance of surgical drapes); verify the declaration of conformity of the supplied batch before use in protocols that require it.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer for this generic non-woven reference: it is a white-label product under Cahnos’s own code (Ref. 10331), so any substitution in tenders or protocols must be confirmed in advance with our technical department. For guidance, the Cahnos catalogue lists the following variants of the same surgical cover family:
| Reference | Description | Equivalence level |
| 11331 | Sterile fenestrated plasticised viscose, 75 x 100 cm, Ø 10 cm, without adhesive | Comparable by category: same dimensions and fenestra; the material changes (plasticised vs absorbent) |
| 10731 | Sterile absorbent viscose fenestrated with adhesive, 75 x 100 cm, Ø 8 cm, 20 g/m² | Comparable by category: same material and format; adds adhesive strip and reduces fenestra diameter (8 cm) |
| 10531 | Sterile absorbent viscose with adhesive, 75 x 100 cm, Ø 8 cm, 20 g/m² | Comparable by category: same material and dimensions; with adhesive and 8 cm fenestra |
| 11231 | Non-sterile fenestrated plasticised viscose, 75 x 100 cm, Ø 10 cm | Comparable by category: same dimensions and fenestration; material and sterility change |
| 10631 | Non-sterile absorbent viscose fenestrated with adhesive, 75 x 100 cm, Ø 8 cm, 20 g/m² | Comparable by category: same dimensions and material; non-sterile, with adhesive and Ø 8 cm |
| 14131 | Disposable sterile absorbent viscose drape, 80 x 100 cm, 20 g/m², without fenestra | Comparable by category: same material and sterility; without fenestra and other dimensions |
Market references (comparable at category level, not 1:1 interchangeable): fenestrated surgical drapes from brands such as 3M/Solventum Steri-Drape (incision drapes with adhesive film), L&R Raucodrape / Naturdrape (fenestrated drapes), Mölnlycke Health Care, Hartmann, Medline and BOENMED cover the same general clinical indication, but differ in grammage (fabrics usually 40–56 g/m² versus 20 g/m²), layer composition (polypropylene laminated with polyethylene versus absorbent viscose), fenestra geometry and regulatory classification. They cannot be treated as exact equivalents: check material, grammage, dimensions, fenestra diameter, sterility, single-use and regulations before substituting. The specific codes of these brands are pending confirmation with the manufacturer or authorised distributor; consult Cahnos’s technical department before using them in a tender.
5. Selection tips and variants of interest
Sterility: use this sterile version for surgery or aseptic technique. If the procedure does not require a sterile field (wound dressings, catheterisation, punctures or examinations), consult the non-sterile family of the same material type with our technical-commercial team.
Format: the 75 x 100 cm size offers wide coverage for extensive interventions. If you need more working surface or a more contained access, consider the formats of the same family according to the anatomical area to be treated.
Fenestra diameter: the manufacturer specifies 10 cm; do not extrapolate this data to other diameters without technical confirmation. If your technique requires a smaller opening or adhesive fixation, consult the variant with adhesive strip and 8 cm fenestra (Ref. 10731).
Material: the absorbent viscose version prioritises liquid retention and softness; if you also need a superior barrier against splashes, consider the plasticised viscose family in the same format and fenestration (Ref. 11331).
Single-use: dispose of after each procedure in accordance with the centre’s healthcare waste management protocol; it is not suitable for re-sterilisation or reuse. Check the integrity of the sterile packaging and the expiry date before each use.
For high-volume orders, continuous supply contracts or purchasing centre quotations, contact your technical-commercial team at Cahnos.



Reviews