Description
1. Commercial Introduction
The Sterile Disposable Surgical Field Drape Sheet of Absorbent Viscose 20 g/m² with Adhesive and Fenestra Ø 8 cm (Ref. 10502) is the reference disposable covering solution for keeping the operating field clean, dry and delimited in localised medical and surgical procedures. Its non-woven viscose fibre fabric combines excellent absorption capacity with an effective barrier against liquids, protecting the patient, the healthcare team and the work surface throughout the intervention. A compact and manageable 50 x 40 cm format, ready to use, with precise surgical access through a central 8 cm fenestration.
2. Technical explanation of the product and procedure
This drape belongs to the family of single-use disposable surgical covering. It is made of non-woven fabric (TNT) of absorbent viscose, a cellulosic fibre structure that provides softness in contact with the skin and a high fluid retention capacity, preventing exudate or washing liquids from spreading outside the work area.
The central 8 cm diameter fenestration precisely delimits the intervention point and allows direct access to the surgical field while the rest of the area remains covered and protected. The adhesive band fixes the drape to the patient’s skin or surface without the need for forceps or accessories, preventing displacement during the procedure and ensuring a stable seal of the sterile field. Due to its sterile and single-use condition, it is intended for operating theatre, minor surgery, wound dressings, punctures, catheterisations and techniques requiring a sterile barrier, eliminating the risk of cross-contamination and simplifying healthcare waste management according to the centre’s protocol.
3. Technical Specifications
| Product type | Disposable sterile field drape sheet with adhesive fenestration |
| Material | Non-woven fabric (TNT) of absorbent viscose |
| Grammage | 20 g/m² |
| Measurements | 50 x 40 cm |
| Fenestration diameter | 8 cm |
| Fixation | Adhesive strip, without the need for forceps |
| Condition | Sterile |
| Use | Single-use (disposable), not suitable for re-sterilisation |
| Advantages | High absorption, secure fixation, precise access, barrier against liquids |
| Application | Localised medical and surgical procedures: minor surgery, wound dressings, punctures, catheterisations, examinations |
| Presentation | Individual sterile unit or in boxes as required |
| Reference (SKU) | 10502 |
Technical note: the 20 g/m² grammage and the 8 cm fenestration diameter correspond to the declared product specification; do not extend these ranges without technical confirmation from the manufacturer. In this category, it is common for manufacturers to declare conformity with standard EN 13795 (barrier requirements and performance of surgical fields); verify the declaration of conformity of the supplied batch before use in protocols that require it.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer for this generic non-woven fabric reference: it is a white-label product under our own code Cahnos (Ref. 10502), so any substitution in tendering or protocol must be confirmed in advance with our technical department.
| Reference | Description | Equivalence level |
| Ref. 10702 | Sterile absorbent viscose fenestrated with adhesive, 50 x 40 cm, Ø 8 cm, 20 g/m² | Direct equivalent: same full specifications (confirm with technical department) |
| Ref. 10504 | Sterile absorbent viscose with adhesive and fenestra, 50 x 80 cm, Ø 8 cm, 20 g/m² | Comparable by category: same material and fenestra, larger format |
| Ref. 10402 | Non-sterile absorbent viscose with adhesive and fenestra, 50 x 40 cm, Ø 8 cm, 20 g/m² | Comparable by category: same dimensions and material; sterility differs |
| Ref. 10602 | Non-sterile absorbent viscose fenestrated with adhesive, 50 x 40 cm, Ø 8 cm, 20 g/m² | Comparable by category: same format and fenestra, non-sterile version |
| Ref. 11502 | Sterile plasticised viscose with adhesive and fenestra, 50 x 40 cm, Ø 8 cm, 20 g/m² | Comparable by category: same dimensions and sterility; material changes (plasticised vs absorbent) |
| Ref. 11504 | Sterile plasticised viscose with adhesive and fenestra, 50 x 80 cm, Ø 8 cm, 20 g/m² | Comparable by category: same weight and fenestra, other material and format |
Market references (comparable at category level, not interchangeable 1:1): fenestrated surgical fields with adhesive from brands such as 3M/Solventum Steri-Drape (incision series with adhesive film), Naturdrape from Lohmann & Rauscher (2-3 layer fenestrated drapes with polyethylene film), BOENMED and Medpos/Trilar Medical cover the same general clinical indication, but differ in grammage (e.g. fabrics of 28-56 g/m² versus 20 g/m²), layer composition (polypropylene laminated with polyethylene versus absorbent viscose) and fenestration diameter or geometry. They cannot be treated as exact equivalents: verify material, grammage, dimensions, sterility, single-use and regulatory classification before substituting. Any external cross-reference code is pending confirmation with the manufacturer or authorised distributor.
5. Selection tips and variants of interest
Format: the 50 x 40 cm format (Ref. 10502) is the most compact and manageable option, recommended for localised anatomical areas, wound dressings and minor surgery; if you require a larger surface, consider the sterile 50 x 80 cm format (Ref. 10504) or the direct equivalent Ref. 10702.
Sterility: for sterile technique or operating theatre always choose the sterile version (Ref. 10502). If the procedure does not require a sterile field (wound dressings, catheterisations, punctures or examinations), the non-sterile 50 x 40 cm versions (Ref. 10402 or 10602) are the most economical alternative.
Fenestration: the diameter specified by the manufacturer is 8 cm; do not extrapolate this data to other diameters without technical confirmation. If your technique requires a larger opening or a material with a greater barrier against liquids, consult the plasticised viscose variants (Ref. 11502) with our team.
Pre-substitution verification: when comparing with other brands, check one by one material, grammage, dimensions, sterility, single-use and regulatory classification before incorporating an alternative product into your protocol.
Waste management: single-use product; dispose of after each intervention according to the centre’s healthcare waste management protocol. Not suitable for re-sterilisation or reuse. For B2B volume conditions, continuous supply contracts or purchasing centre budgets, contact our technical-commercial team at Cahnos.




Reviews