We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Curved silicone thoracic catheter Ch. 32 (CH32) sterile | 6 lateral holes, atraumatic tip and radiopaque strip for pleural drainage

137,83 €

Curved silicone thoracic catheter Ch. 32 (CH32), sterile and single-use, with 6 elliptical and offset lateral holes that ensure fluid, safe and effective pleural drainage during prolonged treatments. Made of ultra-flexible and thermosensitive silicone with high tissue tolerance, it incorporates an atraumatic tip, wave-shaped distal cut for secure connection to the thoracic drainage system, radiopaque strip and length marks for exact positioning under radiological control. Curved format, ideal for anatomical adaptation in tracts with bony or muscular obstacles. Ref. 24157, presentation in a box of 10 units with a minimum order of 100 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
24157

Description

The curved silicone thoracic catheter Ch. 32 from Cahnos is the reference solution for thoracic surgery, pulmonology, emergency and intensive care units that need reliable, sterile pleural drainage suitable for prolonged treatments of several days. Its ultra-flexible and thermosensitive silicone adapts to body temperature, reducing tissue irritation and improving patient comfort throughout the care process. A high-end device designed for hospitals and wholesale distribution seeking clinical safety, positioning precision and an excellent value for money.

Technical explanation of the catheter and the procedure

The thoracic catheter is inserted into the pleural cavity, intraoperatively or percutaneously, to evacuate air (pneumothorax) and fluid (pleural effusion, haemothorax or postoperative exudate) and restore the negative pressure necessary for lung re-expansion. Once connected to the thoracic drainage system, by gravity, with a water seal or with controlled suction, the circuit remains closed and allows continuous monitoring of the output.

In this CH32 model, the intermediate-high gauge is particularly suitable for drainage of considerable volume or in phases of moderate air leak. Its 6 elliptical and offset lateral holes optimise flow and minimise the risk of obstruction, while the atraumatic tip protects tissues during insertion. The curved design favours anatomical adaptation of the tract and the apical or basal orientation of the distal end within the cavity. The wave-shaped distal cut guarantees a secure coupling to the thoracic drainage circuit, and the radiopaque strip together with the printed length marks allow the depth and position of the catheter to be verified by imaging at all times.

Technical specifications

Reference / SKU 24157
Gauge Ch. 32 (CH32 / 32 Fr)
Format Curved
Material Ultraflexible and thermosensitive silicone with high biocompatibility
Drainage openings 6 offset elliptical lateral holes
Tip Atraumatic, minimises insertion injuries
Distal end Wave-shaped cut for connection to the drainage system
Radiological control Radiopaque strip
Positioning Length markings printed on the body
Sterility Sterile individual packaging, single-use
Use Postoperative and prolonged pleural drainage (several days)
Presentation Box of 10 units
Minimum order 100 units

Design and finishes: soft silicone with high biocompatibility, wide drainage channel and smooth surface that favour tissue tolerance in prolonged treatments. Compatible with standard connectors of thoracic drainage systems with water seal or controlled suction.

Equivalences and cross-references

This catheter is part of the Cahnos family of silicone thoracic catheters, available in sizes CH20, CH24, CH28, CH32 and CH36, in straight or curved format. Clinically it is interchangeable with Argyle-type thoracic drainage catheters and with thoracostomy catheters of equivalent Charrière (French) sizes for hospital use.

  • Straight silicone thoracic catheter Ch. 32: ref. 24156 (same silicone and gauge, straight format).
  • Curved thoracic catheter Ch. 32 in standard material: ref. 21046 (same gauge, curved format).
  • Straight thoracic catheter Ch. 32 in standard material: ref. 21043.
  • Curved silicone thoracic catheter: refs. 24151 (CH20), 24153 (CH24), 24155 (CH28) and 24159 (CH36).
  • Straight silicone thoracic catheter: refs. 24150 (CH20), 24152 (CH24), 24154 (CH28) and 24158 (CH36).
  • Accessories: pleural puncture sets 21104 and 21105; 2000 ml drainage bag 21106.
  • Thoracic drainage systems from the Optiline range: sets 27105, 27107 and 27109, with associated tubing and bottle systems.

Selection tips and variants of interest

  • Gauge selection: the CH32 is ideal for postoperative drainage of considerable volume, haemothorax or fistulas with moderate air leak; for standard adult drainage, Ch. 20-24 gauges are recommended and for high-volume drainage or heavy bleeding, the CH36.
  • Straight or curved format: the curved (24157) improves anatomical adaptation in tracts with bony or muscular obstacles and favours the apical or basal orientation of the distal end; the straight (24156) facilitates insertion by Seldinger technique or tunnelling and its fixation along subcutaneous tunnels.
  • Compatibility: always check the gauge and connector of your drainage circuit (water seal or suction) before connecting the catheter.
  • Purchasing logistics: presentation in a box of 10 units with a minimum order of 100 units, aimed at hospital purchasing centres and wholesale distribution. Consult our technical-commercial team for B2B conditions, lead times and formalised quotations.

Additional information

Reference

24157

Gauge

Ch. 32 (CH32 / 32 Fr)

Format

Curved

Material

Ultraflexible and thermosensitive silicone with high biocompatibility

Drainage openings

6 offset elliptical lateral holes

Tip

Atraumatic

Distal end

Wave-shaped cut for connection to the drainage system

Radiological control

Radiopaque strip

Positioning

Length markings printed on the body

Sterility

Sterile individual packaging, single-use

Use

Postoperative and prolonged pleural drainage (several days)

Presentation

Box of 10 units

Minimum order

100 units

Reviews

There are no reviews yet.

Be the first to review “Curved silicone thoracic catheter Ch. 32 (CH32) sterile | 6 lateral holes, atraumatic tip and radiopaque strip for pleural drainage”

Your email address will not be published. Required fields are marked *