Description
Round grooved drain 10 FR with trocar: safe and effective drainage
The round grooved drain 10 FR (10 CH) with trocar and 4/4 perforation is the professional solution for the controlled evacuation of body fluids in the postoperative period. It belongs to the range of grooved silicone drains from the manufacturer Medline and is designed for the operating theatre and the hospital ward: easy to use, sterile and ready to use, with maximum clinical safety for the patient and total comfort for the healthcare team. A reliable reference, backed by Cahnos as a specialist in medical-surgical supplies for the B2B channel.
Technical explanation of the drainage system
Grooved drains are made up of multiple independent channels with a solid centre that allows good flow during drainage. The round configuration keeps the lumen open even under pressure, preventing collapse and blockage due to compression. The 4/4 (complete) perforation is distributed along the entire length of the tube, offering the maximum drainage surface and ensuring constant evacuation of exudate. The open channels minimise the risk of occlusion and hinder tissue ingrowth, favouring atraumatic removal at the end of treatment. The included trocar facilitates precise, controlled insertion, reducing tissue trauma along the track. The flexible, biocompatible silicone material, with a radiopaque strip for X-ray detection, ensures safe in-hospital handling and reliable postoperative monitoring.
Technical specifications
| Parameter | Specification |
| Reference | DYNJWE2188-DQ |
| Gauge | 10 FR (equivalent to 10 CH) |
| Drain shape | Round grooved (independent channels with solid centre) |
| Perforation | 4/4 (complete, along the entire length) |
| Trocar | Included, for guided and minimally invasive insertion |
| Material | Biocompatible silicone with radiopaque strip (X-ray detection) |
| Condition | Sterile, single-use, ready for immediate use |
| Presentation | Box of 10 units |
| Indications | General, abdominal, thoracic and orthopaedic surgery |
Range of round grooved drains with 4/4 perforation at Cahnos
| Reference | Gauge | Shape | Perforation | Trocar | Packaging |
| DYNJWE2188-DQ | 10 FR | Round | 4/4 | Yes | 10/box |
| DYNJWE2189-DQ | 15 FR | Round | 4/4 | No | 10/box |
| DYNJWE2190-DQ | 15 FR | Round | 4/4 | Yes | 10/box |
| DYNJWE2191-DQ | 19 FR | Round | 4/4 | No | 10/box |
| DYNJWE2234-DQ | 19 FR | Round | 4/4 | Yes | 10/box |
| 564012-DQ | 24 FR | Round | 4/4 | Yes | 10/box |
Equivalences and cross-references
This drain belongs to the range of grooved drains from the manufacturer Medline and corresponds to the base reference DYNJWE2188 (10 CH, round, fully grooved with trocar). As an alternative from the same manufacturer with partial 3/4 perforation, the Exuflow range offers the round 10 FR model with trocar (ORHUR150-DQ), useful when a more localised perforated surface is preferred. In larger calibres of the same grooved family, references DYNJWE2190-DQ (15 FR with trocar), DYNJWE2191-DQ (19 FR without trocar) and DYNJWE2234-DQ (19 FR with trocar) complete the series. All these devices can be combined with a silicone bulb-type reservoir or a collection bag to form a completely closed system.
Selection tips and variants of interest
Select the calibre according to the expected exudate volume and the anatomical area to be drained. For low flow rates or short-duration drainage in subcutaneous tissue, the 10 FR calibre with 4/4 perforation is the recommended choice; for higher-volume drainage, consider the 15 FR, 19 FR or 24 FR calibres from the same range. When the procedure requires guided, rapid and minimally invasive insertion, choose the version with trocar; if you prefer externally assisted placement, versions of the same design without trocar are available (DYNJWE2189-DQ and DYNJWE2191-DQ). To maximise the collection surface in wide wound beds, the range of flat grooved drains (DYNJWE2214-DQ, DYNJWE2215-DQ and DYNJWE1348-DQ) offers an anatomical alternative. Always complete the closed drainage system with a suitable reservoir to minimise the risk of postoperative infection. Check the integrity of the sterile packaging before use.




Reviews
There are no reviews yet.