Double-bottle tubing system with lip valve for chest drainage – OPTILINE range (Ref. 27106)

373,45 €

Double-bottle tubing system with lip valve from the OPTILINE range, designed for a secure and leak-tight connection in double-bottle chest drainage. The integrated lip valve acts as an anti-reflux: it prevents the passage of fluids from the water seal towards the patient and functions as a leak or fistula indicator. Manufactured with resistant medical materials, it guarantees a constant and controlled flow both by gravity and with external suction, facilitating continuous monitoring of the drainage. Reference 27106, presentation in a box of 25 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
27106

Description

Maximum safety for your double-bottle chest drainage systems

The double-bottle tubing system with lip valve is an essential accessory for completing the OPTILINE range double-bottle chest drainage systems. This connection element optimises the union between the collection chamber, the water seal and the patient’s chest catheter, ensuring a leak-tight circuit, stable flow and reliable monitoring throughout the entire care process. Designed for the operating theatre, emergency department, ICU and hospital ward, it is the solution your centre needs to work with total confidence and safety.

Technical explanation of the system

In double-bottle chest drainage, the first bottle acts as a fluid collection chamber and the second as a water seal: the distal end of the tube remains submerged under a column of fluid that prevents air from re-entering the pleural cavity, maintaining the negative pressure required for lung re-expansion.

The lip valve incorporated in this tubing system performs a critical dual function: on the one hand, it prevents backflow of fluids from the water seal chamber towards the patient, even during temporary loss of the seal or during transport in the supine position; on the other, it acts as a leak or fistula indicator, enabling early detection of potential problems and facilitating continuous clinical assessment of bubbling and drainage rate. The result is safe, controlled and uninterrupted drainage, both by gravity and with external suction.

Technical specifications

Reference 27106
Product type Double-bottle hose system with lip valve
Compatibility Double-bottle chest drainage systems from the OPTILINE range
Valve function Anti-reflux: prevents backflow of fluids from the water seal
Leak indicator Allows detection of air leaks or fistulas during drainage
Operating mode Drainage by gravity or with external suction
Materials High-quality, resistant and durable medical materials
Design Ergonomic, easy to install and handle for healthcare staff
Yield Constant and controlled flow throughout the entire procedure
Presentation Box of 25 units

Equivalences and cross-references

This tubing system is part of the Cahnos OPTILINE chest drainage range, a modular system with interchangeable components. Its functional equivalent within the same family is the double-bottle PLUS tubing system with lip valve (SKU 27108), configured with the PLUS features of the range.

Completing the circuit: the single-bottle tubing system (SKU 27104), the complete one- and double-bottle sets (SKU 27105 and 27107), the 1,000 ml and 3,000 ml drainage bottles (SKU 27100 and 27101), the replacement airtight cap (SKU 27102) and the fixing supports (SKU 27112, 27113 and 27115). For unidirectional drainage configurations, the range is completed with the chest drainage bag (SKU 27121) and the Heimlich valve (SKU 27116). As it is a standard system, it is interchangeable with the classic pleural drainage configurations by gravity and suction used in routine hospital practice.

Selection tips and variants of interest

If your centre works with double-bottle systems and needs maximum protection against reflux with early leak detection, consider the PLUS variant (SKU 27108). For single-bottle configurations, opt for the OPTILINE tubing system (SKU 27104); if you prefer the complete circuit, sets 27105 and 27107 include the necessary bottles. Always check the leak-tightness of connections before each use, keep spare caps (SKU 27102) available for high-rotation shifts and accompany the system with the appropriate support when working with external suction. Our technical-commercial team at Cahnos can validate the compatibility of these components with your current equipment before placing the order.

Additional information

Reference

27106

Product type

Double-bottle hose system with lip valve

Product line

OPTILINE

Compatibility

Double-bottle chest drainage systems (OPTILINE range)

Valve function

Anti-reflux: prevents backflow of fluids from the water seal

Leak indicator

Allows detection of air leaks or fistulas during drainage

Operating mode

Drainage by gravity or with external suction

Materials

High-quality, resistant and durable medical materials

Design

Ergonomic, easy to install and handle for healthcare staff

Presentation

Box of 25 units