Double-bottle PLUS tubing system with OPTILINE lip valve for chest drainage

415,80 €

Double-bottle PLUS tubing system with anti-reflux lip valve, designed to connect the chest drainage circuit safely and hermetically. It prevents liquid reflux from the water seal chamber, acts as an indicator of leaks or fistula and maintains a constant and controlled flow in gravity or external suction drainage. Compatible with the double-bottle drainage systems of the OPTILINE range, it is manufactured from high-quality medical materials and offers an ergonomic design that is easy to install and handle for healthcare staff. Reference 27108.

International shipping. Import duties and taxes are payable by the recipient.

Reference
27108

Description

Safe and continuous chest drainage with the OPTILINE range

The double-bottle PLUS tubing system with lip valve is the essential connection accessory to complete the double-bottle chest drainage systems of the OPTILINE range from Cahnos. It is designed to optimise the connection between the collection chamber, the water seal and the patient’s chest catheter, ensuring a leak-proof circuit, stable flow and reliable monitoring throughout the care process in the operating theatre, emergency department, ICU and hospital ward.

Technical explanation of the equipment

In double-bottle chest drainage, the first bottle acts as a fluid collection chamber and the second as a water seal: the distal end of the tube remains submerged under a column of fluid that prevents air from re-entering the pleural cavity, maintaining the negative pressure required for lung re-expansion.

The lip valve incorporated in this tubing system performs a critical dual function: on the one hand, it prevents liquid reflux from the water seal chamber towards the patient, even during temporary loss of the seal or during transport in a supine position; on the other hand, it acts as an indicator of leaks or fistula, enabling early detection of potential problems and facilitating continuous clinical assessment of bubbling and drainage rate. The result is safe, controlled and uninterrupted drainage, both by gravity and with external suction.

Technical specifications

Characteristic Specification
Reference 27108
Product type Double-bottle PLUS hose system with lip valve
Compatibility Double-bottle PLUS chest drainage systems (OPTILINE range)
Valve function Anti-reflux: prevents backflow of fluids from the water seal
Leak indicator Allows detection of air leaks or fistulas during drainage
Operating mode Drainage by gravity or with external suction
Materials High-quality, resistant and durable medical materials
Design Ergonomic, easy to install and handle for healthcare staff
Yield Constant and controlled flow throughout the entire procedure
Presentation Box (standard for the OPTILINE range)

Equivalences and cross-references

This tubing system is part of the OPTILINE chest drainage range from Cahnos, a modular system with interchangeable components. Reference 27108 is the PLUS double-bottle variant with lip valve; its functional equivalent within the same family is the double-bottle tubing system with lip valve (SKU 27106).

  • SKU 27104: OPTILINE tubing system for a single bottle, an alternative for single-chamber configurations.
  • SKU 27105: single-bottle OPTILINE set (complete configuration with bottle included).
  • SKU 27107: double-bottle OPTILINE set (complete configuration with bottles included).
  • SKU 27100 / 27101: chest drainage bottles of 1,000 ml and 3,000 ml, collection chambers and water seal of the circuit.
  • SKU 27102: replacement airtight cap for bottles in the range.
  • SKU 27112 / 27115: supports for 1,000 ml and 3,000 ml bottles, stable fixation of the system.

Selection tips and variants of interest

If your facility works with double-bottle systems and requires maximum protection against reflux with early leak detection, reference 27108 is the recommended option due to its PLUS configuration. For single-bottle configurations, consider the OPTILINE tubing system (27104); if you prefer to purchase the complete circuit, sets 27105 and 27107 include the necessary bottles. Always verify the tightness of connections before each use, keep spare caps (27102) available for high-rotation shifts, and accompany the system with the appropriate support (27112 or 27115) when working with external suction. Our technical-commercial team at Cahnos can validate the compatibility of these components with your current equipment before placing the order.

Additional information

Reference

27108

Product line

OPTILINE

Product type

Double-bottle PLUS tubing system

Compatibility

Double-bottle PLUS chest drainage systems

Valve

Anti-reflux lip valve

Valve function

Prevents liquid reflux from the water seal chamber

Leak indicator

Yes, it allows detection of air leaks or fistula

Operating mode

Drainage by gravity or with external suction

Material

High-quality, resistant and durable medical materials

Design

Ergonomic, easy installation and handling

Presentation

Box (standard for the OPTILINE range)

Intended use

Chest and pleural drainage in hospitals, clinics, emergency departments and ICUs