We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Type 6 Emulating Chemical Indicator for Steam – 5 min at 134 °C, Card of 72 x 33 mm, Box of 200 units (ISO 11140-1), Ref. IT27-5.3S

36,00 €

Type 6 Emulating Chemical Indicator (ISO 11140-1) for steam sterilisation, calibrated for a cycle of 5 minutes at 134 °C. Printed card of 72 x 33 mm with indicator ink that changes from purple to green upon completion of the cycle, ensuring thorough control of packs processed in the autoclave. 100 % free of toxic heavy metals. Presentation in a box of 200 units (Ref. IT27-5.3S), manufactured by Pergut Medical.

International shipping. Import duties and taxes are payable by the recipient.

Reference
IT27-5.3S

Description

1. Product Presentation

The Type 6 Emulating Chemical Control (Ref. IT27-5.3S) is the perfect ally for the sterilisation department that demands rigorous and reliable control of every pack processed in steam cycles. Manufactured by Pergut Medical, this single-use indicator is placed inside the packaging before sealing and confirms, through a clear and irreversible colour change, that the load has been exposed to the critical cycle conditions: temperature, exposure time and quality of saturated steam. Its presentation in a box of 200 units ensures a continuous supply for hospitals, clinics, dental practices, medical device processing companies and the pharmaceutical and food industries. Available for immediate purchase and fast delivery.

2. Technical explanation of the procedure

Type 6 emulating chemical indicators, in accordance with standard ISO 11140-1:2014, are the most demanding indicators among chemical process controls: they react to all critical variables of the sterilisation cycle (temperature, exposure time and presence of saturated steam). Unlike simple process indicators (Type 1) or multivariable indicators (Type 4), the Type 6 emulator is calibrated for specific emulation conditions, so that it only reaches its final colour when the cycle has fully met those parameters, offering a pass/fail result with high sensitivity.

The emulator is placed inside the pack or container before sealing. At the end of the cycle, the colour change of the indicator area is checked: a uniform and complete change from purple to green confirms that the pack has received the appropriate treatment; if the change is insufficient or irregular, the process must be reviewed and the load must not be released. The card is laminated on both sides, which prevents migration of the text and indicator inks, maintaining a clean and stable reading even after the cycle.

3. Technical Specifications

Technical data sheet for the Pergut Medical emulator (Ref. IT27-5.3S):

Characteristic Specification
Type Type 6 emulating chemical indicator for steam
Reference IT27-5.3S (SKU Cahnos / manufacturer reference Pergut Medical)
Emulation conditions 5 minutes at 134 °C in saturated steam
Dimensions 72 x 33 mm
Support and composition Printed card support with indicator ink, laminated on both sides to prevent ink migration
Colour change From purple (initial) to green (final) upon completion of the cycle
Processing Steam: 5-minute cycle at 134 °C
Application Exhaustive control of packs processed in a specific steam cycle
Conformity ISO 11140-1:2014 – Type 6; design under standards ISO 9001:2008 and ISO 13485:2012
Safety 100 % free from toxic heavy metals
CE marking No
Shelf life 5 years
Storage 10-30 °C, relative humidity 30-80 %, protected from light; store in the original packaging and away from sterilising agents
Presentation Box of 200 units

Technical properties of the indicator according to standardised tests:

Property Standard Value
Classification ISO 11140-1 Type 6
Colour change ISO 11140-1 Purple to green
Colour stability EN 867-1 (5.5.3) 60 months
Paper support ISO 536 185 g/m²
Double-sided biaxially oriented polyester film ISO 536 12 µm
Colour difference support/indicator ISO 11140-1 > 0.3 points
Colour change in saturated steam at 134 °C ISO 11140-1 5 minutes
Colour change in dry heat at 140 °C EN 867-3 Annex C > 30 minutes
Labels and markings EN 980 Compliant
Expiry ISO 11140-1 Annex 1 60 months

4. Equivalences and Cross-References

This emulator belongs to the range of Type 6 emulating indicators from manufacturer Pergut Medical for steam sterilisation. The same family covers other emulation conditions:

Reference Description Presentation
IT27-5.3S (this product) Emulating chemical control for 5 min at 134 °C, 72 x 33 mm Box of 200 units
IT27-7S00 Emulating chemical control for 7 min at 134 °C / 20 min at 121 °C, 72 x 23 mm Box of 200 units
IT27-3.5S Emulating chemical control for 3.5 min at 134 °C, 72 x 23 mm Box of 200 units
IT27-18YS Emulating chemical control for an 18 min cycle at 134 °C (special prions) Box of units

In the market, this type of control is generically identified as a Type 6 emulator or single-point indicator Type 6 for steam. If your protocol requires a single-parameter process control based on the displacement of fusible wax, the chemical integrators Type 5 (Refs. IT26S and CI105) can be used; for routine multivariable control, Pergut Medical’s Type 4 indicators (Refs. 229 and 232); and for periodic validation of process efficacy, biological steam controls (Ref. BT20).

5. Selection tips and variants of interest

Cycle selection: this reference (IT27-5.3S) is ideal for rapid cycles of 5 minutes at 134 °C in steam. For standard pre-vacuum cycles of 7 minutes at 134 °C or gravity cycles of 20 minutes at 121 °C, choose the IT27-7S00 variant; for 3.5-minute cycles, the IT27-3.5S; and for extended prion cycles (18 minutes at 134 °C), the IT27-18YS.

Routine use: place an emulator inside each pack before sealing and always check the colour change from purple to green upon opening, as the first visual check prior to releasing the load. It is a single-use product: do not reuse.

Recommended accessories: for sealing and external control of packs, complete with adhesive tapes for steam (Refs. 381, 382 or 382-S); for daily validation of air removal in pre-vacuum autoclaves, Bowie-Dick tests (Refs. 24102 or BD125X/20); and for periodic validation of process efficacy, rapid-read steam biological controls (BT222, BT224).

Storage and traceability: keep the product in its original packaging, between 10 and 30 °C, with 30-80 % relative humidity, protected from light and away from sterilising agents, to preserve the integrity of the indicator ink. For scheduled purchases, tenders or special volume conditions in sterilisation departments, consult your technical-commercial advisor at Cahnos.

Additional information

Product type

Type 6 emulating chemical indicator (ISO 11140-1)

Reference

IT27-5.3S

Manufacturer

Pergut Medical

Dimensions

72 x 33 mm

Support

Printed card laminated on both sides

Initial colour

Purple

Final colour

Green

Temperature

134 °C

Cycle time

5 minutes

Processing

Saturated steam

Application

Exhaustive control of packs in specific steam cycles

Regulatory standard

ISO 11140-1:2014 Type 6

Design standard

ISO 9001:2008, ISO 13485:2012

Safety

100 % free from toxic heavy metals

Certifications

No

Shelf life

5 years

Presentation

Box of 200 units

Storage

10-30 °C, RH 30-80 %, protected from light