Description
1. Product Presentation
The Type 5 chemical integrator for steam (reference GM35953) is the essential ally for any sterilisation centre, dental clinic or medical practice that needs to quickly and reliably verify that each pack, tray or container has reached the critical sterilisation conditions. Its visual colour-change reading allows decisions to be made before releasing the load, without the need for additional instruments. It is supplied in a convenient box of 500 units with easy-dispense carton, with multilingual instructions (GB, IT, FR, ES, PT, GR, DE), designed for continuous daily routine use.
2. Technical explanation of the procedure
The Type 5 chemical integrator, conforming to standard ISO 11140-1, is a single-point process control that reacts integrally to the three critical variables of the steam sterilisation cycle: the temperature reached, the exposure time and the quality of saturated steam. Unlike simple process indicators (Type 1) or multivariable indicators (Type 4), the integrator simulates the response of a biological system and offers a much more conclusive pass/fail reading.
It is used in combination with the Helix batch control, which allows the load to be released at cycle level, and its function is to reaffirm the sterilisation conditions inside vessels or containers, at the point of greatest challenge for the steam. The coated indicator shows a clear colour transition from blue to pink: when the front has completed the pass, the load has been exposed to the appropriate conditions; if the colour change is not complete, the cycle must be reviewed and the load must not be released. It is a single-use, non-toxic and lead-free product.
3. Technical Specifications
The main features of this chemical integrator are detailed below:
| Specification | Detail |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 35953 (SKU Cahnos: GM35953) |
| Control type | Type 5 chemical integrator for steam |
| Regulatory standard | ISO 11140-1 – Type 5 |
| Exposure values (SV) | 134 °C – 3.5 min / 121 °C – 15 min |
| Colour change | From blue to pink (lacquer-coated indicator) |
| Features | Non-toxic / lead-free |
| Shelf life | 5 years from date of manufacture |
| Presentation | Box of 500 units in easy-dispense carton |
| Documentation languages | GB, IT, FR, ES, PT, GR, DE |
| Sales unit | Box of 500 units |
| Device type | No medical device |
| EAN | 8023279359534 |
Product data
| Sales unit | Box of 500 units |
|---|---|
| Device type | No medical device |
| EAN | 8023279359534 |
4. Equivalences and Cross-References
There is no official equivalence table validated by the manufacturer that cross-references the 35953 reference with codes from other brands; the references indicated below are comparable at category level (Type 5 chemical integrators for steam, SteriGage-type format) and must always be verified against their technical data sheet and IFU before substituting in a specification or protocol.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level |
|---|---|---|---|
| Pergut Medical / Terragene | Type 5 chemical integrator for steam (dual 121-134 °C, 72 x 23 mm) | IT26S | Comparable by category |
| Pergut Medical / Terragene | Type 5 integrator, strip format, SteriGage type (102 x 15 mm) | CI105 | Comparable by category |
| Crosstex | STEAMPlus Class 5 Steam Integrator | SSI-100 / SSI-250 / SSI-1000 | Comparable by category (not interchangeable 1:1) |
The strip format, units per pack and specific reference differ; always consult with our technical-commercial department at Cahnos before using in a tender.
5. Selection tips and variants of interest
Place one integrator inside each pack, cassette or container, in the area of greatest difficulty for steam penetration, and always check the complete colour change from blue to pink before releasing the load. Remember that it is a single-use product: do not reuse under any circumstances.
To complete your steam sterilisation control system, in the Cahnos catalogue you will find: Type 5 chemical integrators in other formats (IT26S and CI105), Type 4 multivariable indicators, Type 6 chemical emulators for validation of specific cycles and biological steam controls for periodic process validation. Store the product in its original packaging, in a cool, dry place away from sterilising agents, to preserve the integrity of the reactive element. For scheduled purchases, sterilisation centre volumes or tenders, consult your technical-commercial advisor at Cahnos.




Reviews