Description
1. Product Presentation
The Type 5 chemical integrator with moving front (moving front) (reference 35952) is the single-point internal control solution that every sterilisation centre needs to validate the efficacy of its steam cycles. Thanks to its moving front design, it offers the best possible interpretation in the event of any process failure: if the temperature is not reached or the exposure time is too short, the dark colour will not reach the acceptance zone. It is the ideal complement for hospitals, dental clinics, aesthetic centres and companies processing medical supplies that require thorough and routine control in every processed package.
2. Technical explanation of the procedure
Type 5 chemical integrators, as defined in the ISO 11140 standard, are single-point process controls designed to monitor the efficacy of steam sterilisation cycles. Unlike simple process indicators (Type 1) or multivariable indicators (Type 4), the integrator reacts in an integrated manner to the critical variables of the cycle: the temperature reached, the exposure time and the quality of saturated steam. When all three conditions are met, the indicator front moves completely and the dark colour reaches the acceptance zone, providing a very easy-to-interpret accept/reject result.
Reading is immediate and is performed before releasing the load: if the front reaches the acceptance mark, the package has been exposed to the proper conditions; if the movement is insufficient or irregular, the cycle should be reviewed and the load must not be released. It is a single-use product, not reusable. The user manual is supplied in Spanish, French, English and Italian.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35952 |
| Device type | No medical device |
| Indicator type | Chemical integrator with moving front, Type 5 |
| Cycle conditions | Steam 134 °C – 3.5 min |
| Regulatory standard | ISO 11140 – Type 5 |
| Sales unit | Box of 1,000 units (box of 1,000 pcs) |
| EAN | 8023279359527 |
Main characteristics
- Non-toxic and lead-free (non-toxic / lead free).
- Indicator area completely sealed by a protective film.
- Very easy and visual result interpretation.
- Packaged in white aluminium bags with resealable closure.
- Expiry: 5 years from production date.
- User manual: Spanish, French, English and Italian.
4. Equivalences and Cross-References
The reference 35952 corresponds to the official catalogue code for the Type 5 integrator with moving front for steam at 134 °C – 3.5 min. Within the Cahnos catalogue there are other Type 5 chemical integrator controls for steam with which it shares category and standards, although each reference must be verified individually before substitution in a protocol: the dual 121-134 °C integrator in strip format 72 x 23 mm (ref. IT26S / IT26) and the SteriGage-type integrator 102 x 15 mm on aluminium support (ref. CI105). In the international market, this type of control is generically identified as a Type 5 single-point integrator for steam (SteriGage-type format), being comparable by category to the Crosstex STEAMPlus Class 5 Steam Integrator family (SSI-100, SSI-250, SSI-1000), which varies in strip format, units per package and specific reference. There is no equivalence table validated by the manufacturer that allows a 1:1 substitution with other brands; consult the technical department of Cahnos before any change in a specification or protocol.
5. Selection tips and variants of interest
Place an integrator inside each package, cassette or container before closing, in the area of greatest difficulty for steam penetration, and always check the front movement to the acceptance zone upon opening. It is a single-use product: do not reuse under any circumstances. For medium and large packages, the range offers the SteriGage-type format 102 x 15 mm (ref. CI105, box of 250 units) and the dual format 72 x 23 mm (ref. IT26S, box of 200 units). For protocols requiring a calibrated emulator control for a specific cycle, Type 6 chemical emulators can be used (refs. IT27-5.3S, IT27-7S00 and IT27-3.5S); for routine multivariable control, Type 4 indicators (refs. 229 and 232); and for periodic validation of process efficacy, biological steam controls (ref. BT20). Complete the external control system with indicator adhesive tapes for steam (refs. 381 and 382). Store the product in its original packaging, in a cool, dry place away from sterilising agents, to preserve the integrity of the reactive element. For scheduled purchases, sterilisation centre volumes or tenders, consult your technical-commercial advisor at Cahnos.





Reviews