Formaldehyde Chemical Control 105 x 18 mm – Type 4 Multivariable Indicator (ISO 11140-1) for Low-Temperature Formaldehyde Vapour Sterilisation (Box of 250 units, Ref. CD50)

45,00 €

Type 4 multivariable chemical indicator (ISO 11140-1) with printed synthetic film support, designed for routine control of processed packs in sterilisation cycles by low-temperature formaldehyde vapour at 2 and 3%. Dimensions 105 x 18 mm, with clear and stable colour change reading on each load. Presentation in a box of 250 units to continuously supply hospitals, clinics and sterilisation departments. Reference CD50.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CD50

Description

The CD50 formaldehyde chemical control is the perfect ally for the sterilisation department that works with low-temperature formaldehyde vapour and needs rigorous, economical and easy-to-interpret control on every processed pack. It is a Type 4 multivariable chemical indicator, in accordance with the ISO 11140-1 standard, which visually confirms that each pack has been exposed to the appropriate cycle conditions before its release. Its presentation in a box of 250 units ensures a continuous supply for hospitals, clinics, dental practices and medical device processing companies.

What it is and how it works

According to the ISO 11140-1 standard, Type 4 chemical indicators are multivariable indicators: they react to at least two of the critical variables of the sterilisation process. In this case, the indicator responds to the presence and concentration of the sterilising agent (2 and 3% formaldehyde vapour) together with the low-temperature cycle conditions, allowing an unequivocal distinction between processed and unprocessed items. It is placed inside the pack or container and, at the end of the cycle, the colour change of the indicator area is checked: a uniform and complete change confirms that the pack has received the appropriate treatment; if the change is insufficient or irregular, the process must be reviewed and the load must not be released. The printed synthetic film support ensures a clean and stable reading even after the cycle.

Technical specifications

Characteristic Specification
Type Multivariable chemical indicator (multiparametric) Type 4
Reference CD50 (SKU Cahnos)
Dimensions 105 x 18 mm
Concentration range Formaldehyde at 2 and 3%
Processing Low-temperature formaldehyde vapour (LTSF)
Support and composition Printed synthetic film with chemical indicator
Application Routine control of processed packs in sterilisation cycles
Conformity ISO 11140-1 – Type 4
Storage Cool, dry place, away from sterilising agents and direct light; keep in original packaging
Presentation Box of 250 units

Equivalences and cross-references

The CD50 belongs to the Pergut Medical family of Type 4 multivariable indicators, which covers all common sterilisation methods. It shares the format and synthetic film support with the rest of the range to select the specific variant for each process:

Reference Description Presentation
CD50 (this product) Formaldehyde chemical control, 105 x 18 mm Box of 250 units
CD40 Gas plasma chemical control (hydrogen peroxide), 105 x 18 mm Box of 250 units
CD30 Dry heat chemical control (160 °C), 105 x 18 mm Box of 250 units
CD16 Ethylene oxide chemical control, 200 x 16 mm Box of 250 units
229 / 232 Chemical control Sterigut steam, 190 x 18 mm / 105 x 18 mm Box of 250 units
KH2X15F1P Helix Test PCD kit + strips for formaldehyde CHEMDYE® Kit with strips

For the control of hollow loads and safe release in formaldehyde processes, it can be complemented with the Helix Test PCD kit (ref. KH2X15F1P), and for periodic validation of process efficacy, with the specific biological controls for formaldehyde from the BT family. Our technical-commercial department can provide you with a comparison with the reference currently in use at your facility.

Selection tips and variants of interest

Place an indicator inside each pack before closing and always check the colour change upon opening, as the first visual control prior to load release. It is a single-use product: do not reuse. Remember that the chemical indicator complements, but does not replace, biological controls in load release. If your department also works with steam, dry heat, ethylene oxide or gas plasma, consult the rest of the Type 4 multivariable indicators in the range to select the specific variant for each process. Keep the product in its original packaging, in a cool, dry place away from sterilising agents, to preserve the integrity of the indicator ink. For scheduled purchases or special volume conditions in sterilisation departments, consult your technical-commercial advisor at Cahnos.

Additional information

Product type

Multivariable chemical indicator Type 4 (ISO 11140-1)

Reference

CD50

Dimensions

105 x 18 mm

Concentration

Formaldehyde at 2 and 3%

Support

Printed synthetic film with chemical indicator

Processing

Low-temperature formaldehyde vapour (LTSF)

Application

Routine control of packs in sterilisation cycles

Regulatory standard

ISO 11140-1 – Type 4

Presentation

Box of 250 units

Storage

Cool, dry place, away from sterilising agents and direct light