3M™ COMPLY™ STERIGAGE™ 1243A Chemical Integrator for Steam – Class 5 (ISO 11140-1) – Box of 1,000 units | Ref. 35959

228,00 €

The 3M™ COMPLY™ STERIGAGE™ 1243A chemical integrator is a single-point control Class 5 conforming to ANSI/AAMI/ISO 11140-1:2005, designed to verify inside each pack that the critical conditions of the steam sterilisation cycle (temperature, time and saturated steam) have been achieved. Its moving front technology (moving front ink) offers an immediate and unequivocal «Accept or Reject» reading, with a response correlated with a biological indicator at three time/temperature relationships under ideal conditions. Valid for cycles of 250-275 ºF (118-138 °C). Presentation in a box of 1,000 units. For large orders you can request a quote.

Sales unit: caja de 1000
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35959

Description

1. Introduction

The 3M™ COMPLY™ STERIGAGE™ 1243A is the reference chemical integrator for internal pack control in sterilisation centres, operating theatres and instrument processing services. It is a single-point control that is placed inside each pack, cassette or container to confirm, before releasing the load, that the steam has acted under the appropriate conditions. A professional single-use solution with immediate visual reading and no need for additional instrumentation.

2. Technical explanation of the procedure

Class 5 chemical integrators, defined in standard ISO 11140-1, react in an integrated manner to the critical variables of the steam sterilisation cycle: the temperature reached, the exposure time and the quality of saturated steam. When all three conditions are met, the indicator front moves completely to the acceptance mark, providing a clear «Accept or Reject» result thanks to moving front ink technology.

The response of the STERIGAGE™ 1243A is correlated with a biological indicator at three time/temperature relationships under ideal steam sterilisation conditions. This makes it possible to identify non-sterile instruments before they enter the sterile field and helps to detect process errors by isolating problems in individual packs. It is a single-use, non-reusable product and must be placed in the area of greatest difficulty for steam penetration in each pack.

3. Technical Specifications

Brand 3M
Sales unit box of 1000 pcs (box of 1,000 units)
Device type No medical device (not a medical device)
Model / Reference COMPLY™ STERIGAGE™ 1243A · Ref. 35959
Control type Single-point chemical integrator, Class 5 (ANSI/AAMI/ISO 11140-1:2005)
Reading technology Moving front (moving front ink): easy-to-interpret «Accept / Reject» reading
Sterilisation process Steam (cycles of 250-275 ºF / 118-138 °C)
Biological correlation Response correlated with biological indicator at three time/temperature relationships under ideal conditions
Indicator window 2 mm x 3.7 cm
Use Internal control in packs, cassettes and containers; single-use, not reusable
Regulatory standard Conforms to the requirements of ANSI/AAMI/ISO 11140-1:2005

4. Equivalences and Cross-References

The STERIGAGE™ 1243A is generically identified on the market as a single-point SteriGage-type integrator for steam. In the Cahnos catalogue there are Type 5 integrator controls comparable at category level (not 1:1 interchangeable), such as the dual 121-134 ºC SteriGage-type integrator (SKU IT26S, Pergut/Integron) and the 102 x 15 mm SteriGage-type format (SKU CI105). As an external reference for the segment, the Crosstex STEAMPlus Class 5 integrators (SSI-100, SSI-250, SSI-1000) are listed. There is no exact equivalence table validated by the manufacturer that cross-references this reference with codes from other brands; always verify the strip dimensions, the colour-change conditions and the IFU before substituting one reference for another in a specification or protocol.

5. Selection tips and variants of interest

Place an integrator inside each pack, cassette or container before closing, in the area of greatest difficulty for steam penetration, and always check the complete movement of the front and the «Accept» mark when opening. Do not reuse the integrator under any circumstances.

For external load control, the system can be completed with indicator adhesive tapes for steam and, for periodic validation of process efficacy, with biological steam controls. Store the product in its original packaging, in a cool, dry place away from sterilising agents, to preserve the integrity of the reactive element. For scheduled purchases, sterilisation centre volumes or tenders, consult your technical-commercial advisor at Cahnos. For large orders you can request a quote.

Additional information

Family

COMPLY STERIGAGE

Model

1243A

Manufacturer reference

35959

Control type

Single-point chemical integrator, Class 5 (ANSI/AAMI/ISO 11140-1:2005)

Reading technology

Moving front (moving front ink): reading «Accept / Reject»

Sterilisation process

Steam (250-275 ºF / 118-138 °C)

Biological correlation

Correlated with biological indicator at three time/temperature relationships

Indicator window

2 mm x 3.7 cm

Use

Internal control in packs, cassettes and containers; single-use, not reusable

Presentation

Box of 1,000 units

Device type

No medical device (not a medical device)

Presentacion

Box of 1000

Documentation

📄 DatasheetEnglish PDF

Reviews

There are no reviews yet.

Be the first to review “3M™ COMPLY™ STERIGAGE™ 1243A Chemical Integrator for Steam – Class 5 (ISO 11140-1) – Box of 1,000 units | Ref. 35959”