Metal mesh basket for Branson 5800 ultrasonic cleaner – Perforated tray compatible with codes 35521-35522-35523 (Ref. 35528)

329,65 €

Metal mesh basket (perforated tray) designed for the Branson 5800 ultrasonic cleaner, reference model 35520-2. Compatible with codes Ref. 35521, 35522 and 35523, this accessory allows you to safely immerse and remove the instruments inside the cleaning tank, keeping the part separated from the bottom for homogeneous cavitation and avoiding direct contact with the surface of the tank. Manufactured in metal mesh construction with a perforated structure that guarantees rapid drainage and optimal transmission of ultrasonic waves. Sold per unit (1 pc). Ideal spare or expansion accessory for sterilisation centres, clinics and laboratories working with the Branson 5800 series. Product not classified as a medical device. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35528

Description

1. Product Presentation

The metal mesh basket for the Branson 5800 ultrasonic cleaner (Ref. 35528) is the accessory that completes the equipment of your sterilisation centre, clinic or laboratory. Manufactured specifically for model 35520-2 of the Branson 5800 series, this perforated tray allows you to organise the instruments inside the ultrasonic cleaning tank, facilitating the loading and unloading of parts and protecting them during the cleaning cycle.

Direct compatibility with codes Ref. 35521, 35522 and 35523. Supplied per unit (1 pc) and requires no installation: simply place it inside the tank.

2. Technical explanation of the equipment and procedure

Ultrasonic cleaners such as the Branson 5800 remove dirt through the phenomenon of cavitation: the transducer generates high-frequency waves in the cleaning liquid that produce micro-bubbles; when they implode, these bubbles detach particles and contaminants from the surface of submerged objects.

For cavitation to work effectively, the instruments must not rest directly on the bottom of the tank, as this blocks the transmission of the waves and can damage both the part and the tank itself. The perforated tray or mesh basket keeps the instruments raised and suspended within the liquid, allowing the ultrasonic energy to reach the whole part evenly. Its open structure also facilitates liquid drainage when the basket is removed and reduces the risk of micro-impact between instruments during the cycle.

3. Technical Specifications

The product details according to the manufacturer’s catalogue are set out below:

Available references Description Sales unit
GM35528 (Ref. 35528) Metal mesh basket for Branson 5800 ultrasonic cleaner – model 35520-2 1 pc
35521 · 35522 · 35523 Compatible codes (baskets/trays from the same Branson 5800 series) 1 pc

Product data

Manufacturer GIMA
Manufacturer reference 35528
Product type Metal mesh basket / perforated tray for ultrasonic cleaner
Compatibility Branson 5800 ultrasonic cleaner (model 35520-2)
Supported codes 35521, 35522, 35523
Sales unit 1 pc
Device type No medical device
EAN 8023279355284

4. Equivalences and Cross-References

Ref. 35528 belongs to the accessory family of the Branson 5800 ultrasonic cleaner (model 35520-2) from the manufacturer’s catalogue. The codes 35521, 35522 and 35523 correspond to baskets/trays from the same series, indicated by the manufacturer as compatible with this equipment model.

No validated equivalence table with other manufacturers is available for this reference. If you need to check the accessory against your specific equipment or against references from other brands of ultrasonic cleaners, please consult our technical-commercial department at Cahnos before formalising a substitution.

5. Selection tips and variants of interest

Check the model of your ultrasonic cleaner before selecting the basket: this reference (35528) is intended for the Branson 5800 (model 35520-2) and is compatible with codes 35521, 35522 and 35523 from the same series. Always use the basket or perforated tray during instrument cleaning cycles to avoid direct contact with the bottom of the tank and optimise the action of cavitation.

After the cleaning cycle, remove the basket and allow the instruments to drain on the tray before moving on to the rinsing, drying and sterilisation stages. To complete the equipment of your sterilisation centre, you can combine this accessory with the rest of the Branson series baskets and trays, as well as with the ultrasonic cleaning tanks available at Cahnos. For institutional orders, volume conditions or compatibility queries with your equipment, contact our technical-commercial team.

Additional information

Manufacturer reference

35528

Product type

Metal mesh basket / perforated tray for ultrasonic cleaner

Compatibility

Branson 5800 ultrasonic cleaner (model 35520-2)

Compatible codes

35521, 35522, 35523

Device type

No medical device

EAN

8023279355284

Presentacion

Unit

Documentation

📄 DatasheetEnglish PDF
📜 CertificatesDispositivo non medico PDF

Reviews

There are no reviews yet.

Be the first to review “Metal mesh basket for Branson 5800 ultrasonic cleaner – Perforated tray compatible with codes 35521-35522-35523 (Ref. 35528)”

Your email address will not be published. Required fields are marked *