Description
1. Product Presentation
The TITANOX dry heat steriliser, with a capacity of 3 litres, is the ideal hot air sterilisation equipment for processing metal instruments in practices, clinics, hospitals, laboratories and technical studios for aesthetics and tattooing. Its all-stainless-steel construction, reliable temperature control and timer with automatic shut-off make it a robust, safe and long-lasting solution for everyday healthcare.
It is a Class II B medical device compliant with Regulation (EU) 2017/745, manufactured in Italy and distributed in Spain by Cahnos. Manufacturer’s reference: 35575 (SKU GM35575).
2. Technical explanation of the equipment and procedure
Dry heat sterilisation (hot air) eliminates microorganisms through thermal oxidation of their proteins, without the need for steam or moisture, being the recommended method for metal instruments and materials that cannot tolerate steam autoclaves. The TITANOX reaches and maintains the working temperature by means of a stainless steel sheathed heating element, and distributes heat evenly thanks to its internal structure, grid and removable perforated tray, also in stainless steel.
The chamber and the hinged lid are insulated with high-quality glass wool and sealed with a non-toxic silicone rubber gasket, ensuring thermal retention and operator safety. The unit incorporates a timer from 0 to 120 minutes that switches off the appliance at the end of the programmed time, a safety thermostat, and two green indicator lights that show mains connection and heating element operation. Temperature regulation and reading are carried out via a thermometer probe and a thermoregulator probe with a range of 0° to 200 °C, allowing the cycle to be adjusted to the load and to the instrument manufacturer’s recommendations.
3. Technical Specifications
Technical specifications:
| Capacity | 3 l |
|---|---|
| Timer | 0 to 120 minutes |
| Probe thermometer | 0° to 200 °C |
| Probe thermoregulator | 0° to 200 °C |
| Operating voltage | 230 V – 50/60 Hz |
| External dimensions | 400 × 295 × 170 mm |
| Interior dimensions | 300 × 125 × 80 mm |
| Classification | Class II B, medical device Regulation (EU) 2017/745 |
Construction features:
| External structure | Stainless steel |
|---|---|
| Internal structure, grid, removable perforated tray and hinged lid | Entirely in stainless steel |
| Gasket / insulation | Non-toxic silicone rubber gasket on frame and lid, insulated with high-quality glass wool |
| Heating element | Stainless steel sheathed heating element |
| Time control | Timer from 0 to 120 minutes with automatic shut-off |
| Safety | Safety thermostat |
| Indicators | Green indicator light (right): mains connection · Green indicator light (left): heating element in operation |
| Documentation | Manual in GB, FR, IT (ES on request) |
| Origin | Made in Italy |
Product data:
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 ud |
| Device type | Medical device |
| Device class | II B |
| CND | Z12011307 |
| EAN | 8059304700002 |
4. Equivalences and Cross-References
The TITANOX 3 l steriliser is a unit of our own design and manufacture (factory reference 35575), so no validated 1:1 equivalence table with other dry heat oven manufacturers on the market is available from reliable, verified sources. In the event of any tender or replacement by another brand, it is recommended to check with the technical department of Cahnos the actual chamber capacity, temperature range, type of control (timer and thermoregulator) and regulatory classification of the alternative unit. References from this same family (other volumes and configurations of the TITANOX range) are the most suitable variants to cover higher or lower capacity requirements.
5. Selection tips and variants of interest
The 3 l capacity of this oven is suitable for small and medium loads of metal instruments: forceps, scissors, needle holders, trays and small practice sets. For larger working volumes, it is recommended to consider other dry heat sterilisation models with a larger chamber that allow complete trays to be processed in a single cycle.
Remember to place clean and dry instruments on the grid or the perforated tray, without overloading the chamber, to allow homogeneous circulation of hot air. Always respect the times and temperatures indicated by the instrument manufacturer and periodically validate each cycle with chemical and biological controls according to the protocol of your sterilisation centre.
For special B2B conditions, hospital supply agreements or validation of alternatives, contact the technical-commercial team of Cahnos. For large orders you can request a quote.