Description
1. Commercial Introduction
The E9 24-litre autoclave is a class B benchtop steam steriliser designed for professional environments that demand reliability, speed and rigorous documentary control of every cycle. It combines a modern, compact aesthetic with an expandable traceability concept: the equipment grows at the pace of your clinic’s or practice’s needs, as it can start with basic digital management and incorporate, when required, up to three different printing kits.
Designed for the daily work of dental clinics, medical practices, podiatry and aesthetic medicine centres, laboratories and veterinary clinics, the E9 offers the security of a complete and verifiable sterilisation process, with an intuitive interface that reduces staff training and speeds up routine sterilisation tasks.
2. Technical explanation of the equipment
The E9 autoclave is a class B steam steriliser in accordance with standard EN 13060, which means it can process bagged solid loads, hollow instruments, porous loads and unwrapped loads using cycles with fractionated pre-vacuum that guarantee air removal and correct steam penetration throughout the load.
The equipment incorporates a 4.3″ colour touchscreen (E-Touch concept) with clear icons that allow immediate menu navigation. It offers five type B cycles (121 °C, 134 °C, 134 °C Prion and two rapid 134 °C versions), as well as type N and S cycles protected by password and verification tests (Vacuum, Helix and Bowie & Dick) programmable, with automatic reminder. The timer (E-Timer) allows programming the start of cycles and tests at the desired time, for example before the clinic opens.
Data management is one of its strong points: the SD card and Ethernet connection come as standard and allow transferring the records of each cycle to the computer using the E-Memory management software (included free of charge), complemented by the optional WiFi kit (E-WiFi). For paper traceability, the E9 allows the installation at any time of three optional printing kits: internal thermal paper printer (Print Set 1), internal barcode label printer (Print Set 2) and external label printer for high volumes (Print Set 3).
Regarding process safety, the E9 incorporates advanced control systems shared with the range platform: the Inspection System facilitates interior cleaning, the Dirt Control System separates clean and dirty water flows preventing recontamination, the conductivity meter constantly controls water quality and the air-water separator optimises the operation of the vacuum pump.
3. Technical Specifications
The technical specifications of the E9 24-litre autoclave are detailed below, according to the manufacturer’s official data sheet:
| Parameter | Specification |
|---|---|
| Set type | Class B benchtop steam autoclave |
| Chamber capacity | 24 litres |
| Compliance | Class B in accordance with EN 13060; medical device class IIb |
| Display | 4.3″ colour touchscreen (E-Touch interface) |
| Sterilisation cycles | 5 type B cycles: 121 °C, 134 °C, 134 °C Prion, 134 °C Rapid and 134 °C Prion Rapid |
| Additional cycles | Type N (N134, N121) and S (S134, S121), activatable with password |
| Verification tests | Vacuum, Helix and Bowie & Dick; programmable and with reminder |
| Maximum load | 6 kg (bagged solid products) |
| Trays | 5 trays included; standard tray holder 19.5 x 19.5 x 40 cm; tray 18.5 x 2 x 38 cm |
| Chamber | Stainless steel |
| Connectivity | SD card and Ethernet as standard; optional WiFi (E-Wifi kit) |
| Management software | E-Memory included (storage, search, printing and sending of records) |
| Paper traceability | Expandable with 3 optional printing kits (Print Set 1, 2 and 3) |
| External dimensions | 46 x 43.5 x 61 cm (length x height x width) |
| Weight | 47.5 kg (empty machine with tray holder and tray) |
| Power supply | 230 V, 50/60 Hz |
| Power consumption | 2300 W |
| Water consumption | 0.3 litres per cycle |
| Control systems | Inspection System, Dirt Control System, conductivity meter, air-water separator |
| CE marking | Medical device class IIb; CE ref. SSUM24L2023 (according to the manufacturer’s official data sheet) |
Equipment traceability options (compatible accessories from the same range):
| Accessory | Function | Reference |
|---|---|---|
| Print Set 1 | Internal thermal paper printer: printed cycle record for filing | 120010 |
| Print Set 2 | Internal adhesive label printer with cycle data and barcodes (approx. 300 labels/roll) | 120011 |
| Print Set 3 | External adhesive label printer for continuous production and large quantities | 120012 |
4. Equivalences and Cross-References
The Cahnos SKU for this equipment is 115712. Cahnos uses its own code for this product; the manufacturer’s official reference for the 24-litre E9 autoclave is distributed in the sector under code 115780, consistently cited by authorised distribution. This code cannot be verified in official public sources from the manufacturer, so it must be confirmed with the manufacturer or with the Cahnos technical department before use in tenders or technical specifications, as the range has evolved with successive versions of the model.
Class B autoclaves from other manufacturers are not interchangeable 1:1 with this autoclave without prior technical validation: each manufacturer uses proprietary control platforms, hydraulic systems and documentation software. The following alternatives have been checked against the official catalogue of each cited manufacturer (official Tuttnauer catalogue and official W&H website) and are classified as comparable by category, not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| MELAG | Vacuklav 24 (Vacuklav range) | Vacuklav 24 B+ | Comparable by category (not interchangeable 1:1) | Class B autoclave according to EN 13060 with a 45 cm deep chamber and approximate volume of 23 litres, with fixed water supply connection and proprietary documentation. It differs from the E9: volume (23 L vs 24 L), power consumption (2100 W vs 2300 W), number of trays and connectivity platform. Data verified on the manufacturer’s official website; compare technical data sheet and IFU field by field before any replacement. |
| Tuttnauer | Elara (bench-top range) | Elara 10 | Comparable by category (not interchangeable 1:1) | Class B pre-vacuum/post-vacuum autoclave (EN 13060) with a 23-litre chamber, touchscreen, integrated thermal printer, SD card (256 MB) and USB/RS232 ports; 4 trays and 2900 W power. It differs from the E9: volume (23 L vs 24 L), number of trays (4 vs 5), power consumption and lack of the Ethernet/WiFi connectivity platform and E-Memory software. Data verified in the official Tuttnauer catalogue (Elara Series brochure); compare technical data sheet and IFU field by field. |
| W&H | Lisa (bench-top range) | Lisa 22 | Comparable by category (not interchangeable 1:1) | Class B steam steriliser in accordance with EN 13060 of 22 litres, with rapid cycles and proprietary Eco Dry+ technologies and EliSense/EliTrace traceability. It differs from the E9: capacity (22 L vs 24 L), shorter trays and W&H’s own control and documentation platform. Data verified on the manufacturer’s official website; compare technical data sheet and IFU field by field. |
There is no equivalence table validated by the manufacturer that cross-references reference 115712 with codes from other brands; consult the technical department before using in tenders. At category level, the following equipment can also be considered comparable counterparts (class B, EN 13060, bench-top format, capacity range 17–29 litres): Wosapit/Mocom, Sercon and Cominox, pending confirmation against each manufacturer’s technical data sheet and IFU: before proposing a replacement, the chamber volume, number and size of trays, available cycles, display, connectivity, external dimensions, weight, power consumption, water consumption and regulatory classification (CE/MDR) of the specific model must be verified field by field.
Within the manufacturer’s own range, the homologous variants available in the Cahnos catalogue are: E8 24 L (SKU 115716), entry-level model with E-Timer; E10 24 L (SKU 115750), the higher 24-litre generation with high-performance vacuum pump; and EXL 29 L (SKU 115760), higher-capacity version for high load volumes. They share platform, accessories and control systems, but differ in features, connectivity and price, so they should be assessed according to actual workload.
5. Selection tips and variants of interest
Capacity tailored to your activity: with its 24 litres and 5 trays, the E9 is the balanced option for medium-sized clinics with several surgeries, medical practices, podiatry, aesthetic medicine and veterinary. If your workload is low and you are looking for an economical entry point, consider the E8 24 L (115716); if you process large volumes or long instruments continuously, consider the EXL 29 L (115760).
Plan traceability from the outset: the digital recording (SD card + Ethernet + E-Memory software) comes as standard and is sufficient for archiving cycles on the computer. If you need a physical record, install the Print Set 1 (thermal paper, ref. 120010) or the Print Set 2 (adhesive barcode labels, ref. 120011) for load labelling; the Print Set 3 (ref. 120012) is intended only for continuous production of large quantities of labels. All three kits can be installed at any time, even on autoclaves already in service.
Complete the connectivity: if you wish to view data from mobile devices or integrate into the clinic network without cabling, add the optional WiFi kit (E-WiFi) compatible with the range.
Water quality: use distilled or demineralised water of controlled quality; the unit’s conductivity meter continuously monitors the water and, together with the Dirt Control System, protects the hydraulic circuit and extends the service life of the pump and chamber.
Maintenance and checks: carry out the periodic tests (Vacuum, Helix, Bowie & Dick) using the unit’s scheduling and reminder function, and take advantage of the Inspection System for quick and frequent cleaning of the chamber. For volume purchases, supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.