Description
TST Secu-wrap Standard Blue Paper 100×100 cm
The TST Secu-wrap standard blue paper 100×100 cm is the packaging solution that every sterilisation centre needs to protect and keep its medical devices and equipment sterile. Its blue colour facilitates visual identification of the material in the processing circuit and its square format, in pre-cut sheets, adapts precisely to medium surgical trays, instrument boxes, laparoscopy equipment and packages of a certain volume, offering clean sealing and ergonomic handling for healthcare staff. A professional-use medical device, reliable and ready to use.
Technical explanation of the material
This paper belongs to the family of synthetic nonwovens (TST) and is composed of a trilaminate SMS (Spunbond-Meltblown-Spunbond) sheet of 100% polypropylene dyed in the mass in blue, with a grammage of 43 g/m² (SMS 200 series). The SMS structure combines two outer layers of continuous filament that provide high mechanical strength and an inner melt-blown layer that acts as a true microbial barrier: it blocks the entry of microorganisms and at the same time allows the penetration and evacuation of the sterilising agent. As it contains no cellulose, it is fully suitable for low-temperature processes such as vaporised hydrogen peroxide and gas plasma, as well as withstanding steam, ethylene oxide and formaldehyde. It is used as a single-use sterile barrier system, in accordance with the requirements of standards ISO 11607-1 and EN 868-2 for sterilisation packaging.
Technical specifications
| Characteristic | Detail |
|---|---|
| Reference | 27401010 |
| Type | Synthetic non-woven paper for single-use sterile packaging |
| Measurements | 100 x 100 cm |
| Composition | Trilaminate polypropylene (SMS) sheet of 43 g/m², blue-dyed synthetic fibre, 100% polypropylene |
| Colour | Blue |
| Format | Pre-cut sheets |
| Presentation | Box of 150 sheets |
| Sterilisation methods | Water vapour, ethylene oxide, formaldehyde, hydrogen peroxide and gas plasma |
| Application | Medium surgical trays, dental instruments, laparoscopy equipment and medium-volume packages |
| Conformity | ISO 11607-1 and EN 868-2; class I medical device with CE marking |
| Storage | Clean, dry place, keeping the original packaging until use |
Technical properties of the SMS fabric of 43 g/m²
| Property | Standard | Value |
|---|---|---|
| Measurements | EN 868-2, section 7 | From 30×34 cm to 140×140 cm |
| Medical grade paper | ISO 536 | 43 g/m² |
| Dry burst resistance | ISO 2758 | >306 kPa |
| Wet burst resistance | ISO 3689 | >306 kPa |
| pH of aqueous extract | ISO 6588 | 6.26 |
| Water absorption index (Cobb 60) | ISO 535 | 0 g/m² |
| Tear resistance (Elmendorf) | ISO 6383 | 537 mN |
| Sulphate content | ISO 9198 | 0.07% |
| Water repellency | EN 868-2, Annex E | >500 min |
| Expiry | — | 5 years from date of manufacture |
| Recommended storage | — | 10-30 ºC and 30-60% relative humidity |
Standard size programme of the 43 g/m² SMS range
| Code | Measurements | Units per box |
|---|---|---|
| 27403034 | 30 x 34 cm | 700 |
| 27405050 | 50 x 50 cm | 350 |
| 27406060 | 60 x 60 cm | 360 |
| 27407575 | 75 x 75 cm | 180 |
| 27409090 | 90 x 90 cm | 150 |
| 27401010 | 100 x 100 cm | 150 |
| 27401212 | 120 x 120 cm | 102 |
| 274140140 | 140 x 140 cm | 100 |
Equivalences and cross-references
This paper corresponds to the Pergut SMS RELIANCE 200 range (43 g/m²), a cellulose-free synthetic nonwoven with multi-process compatibility. Its direct equivalent within the Cahnos catalogue in the same 100×100 format is the TST Regular Blue SMS 300 paper of 50 g/m² (ref. 311028), which shares dimensions and sterilisation cycles and differs only in its higher grammage and mechanical strength. As an alternative of another material, the mixed nonwoven DEXTER paper of 100×100 (ref. TST100100, 57 g/m²) covers steam, ethylene oxide and formaldehyde, but not hydrogen peroxide or gas plasma processes. For very heavy loads or with sharp edges, the double-layer SMS of 60 g/m² is recommended, and for light packages the standard green crepe paper of 60 g/m². All these ranges comply with ISO 11607-1 and EN 868-2, which guarantees traceability and safety in the sterilisation process.
Selection tips and variants of interest
To choose the most suitable format, always consider the size of the device to be sterilised, leaving a recommended minimum margin of 25-30 mm on each side to ensure correct sealing and safe aseptic opening. The 100×100 cm format is especially suitable for medium surgical trays, dental instruments, laparoscopy equipment and packages of a certain volume; for small instruments choose the 50×50, 60×60, 75×75 or 90×90 cm formats, and for large packages the 120×120 or 140×140 cm ones. Always remember to combine this paper with sterilisation indicator tapes and class 5 chemical indicators, record the batch traceability and store it in a cool, clean and dry place (10-30 ºC, 30-60% relative humidity), respecting the 5-year expiry date from the manufacturing date. As it is a single-use barrier system, it must not be reused after a sterilisation cycle. At Cahnos you have the entire range of SMS formats of 43 g/m² with the same multi-process compatibility to adapt to the needs of your centre.





Reviews
There are no reviews yet.