2-line steam labels for labeller 35980 – Box of 12,000 units (24 rolls of 500) with process indicator ISO 11140-1 Class 1 – Ref. 35984

140,60 €

2-line steam sterilisation indicator labels for the labeller Ref. 35980, in economical box presentation of 12,000 units (24 rolls of 500 labels). They incorporate a Class 1 process indicator according to ISO 11140-1 that changes from pink to brown upon completion of the cycle, allowing verification at a glance that the load has been subjected to sterilisation. They feature double adhesive backing, non-toxic ink and are latex-free.

Sales unit: caja de 12000
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35984

Description

2-line steam labels – The traceability consumable for your Sterilisation Centre

1. Product Presentation

The 2-line steam labels (Ref. 35984) are the reference consumable for clear, permanent and auditable identification of each load processed in sterilisation services. Designed for use with the labeller Ref. 35980, these self-adhesive labels ensure sharp marking of dates, batches and operator codes, reinforcing traceability and document control in operating theatres, sterilisation centres (SEC), dental clinics and high-turnover hospital areas.

Its integrated process indicator adds a differential value: it allows visual confirmation, without additional equipment, that the package has completed the steam sterilisation cycle, contributing to patient safety and regulatory compliance of the service.

2. Technical Explanation

These labels are designed for use with the manual labeller Ref. 35980, which transfers ink via its printing system onto the label surface with each press. The first print line can display up to 3 alphabetic digits + 11 numbers, while the second line supports 14 numbers, allowing orderly recording of the sterilisation date, expiry date, batch number and steriliser number.

The label incorporates a steam process indicator (Class 1, ISO 11140-1): after the sterilisation cycle is completed, the indicator undergoes an irreversible colour change, from its original pink colour to brown, confirming at a glance that the load has been exposed to the sterilising agent. Its double adhesive backing ensures stable fixation during handling and storage of the processed material, and its ink is non-toxic and latex-free.

3. Technical Specifications

The main technical features of this consumable are detailed below:

Brand
Manufacturer reference 35984
Compatible equipment reference Labeller Ref. 35980
Product type Self-adhesive steam label with process indicator, 2 print lines
First print line Up to 3 alphabetic digits + 11 numbers
Second print line Up to 14 numbers
Sterilisation method Steam (autoclave)
Process indicator Steam, Class 1 according to ISO 11140-1
Colour change From original pink to brown after the cycle
Adhesive backing Double adhesive
Ink Non-toxic
Latex Latex-free
Sales unit Box of 12,000 units (24 rolls of 500 labels)
EAN 8034049914648
Device type Not a medical device

4. Equivalences and Cross-References

This reference is complemented by the brand’s own labelling system: the natural application equipment is the steam labeller Ref. 35980. For load identification in three-line formats with process indicator, Cahnos also offers DUPLEX labels of 29 × 28 mm for manual labellers (Ref. 2712), along with variants without indicator (Refs. 27141 and 2713) and the application equipment Ref. 273 with its inking replacement Ref. 187. Always verify the compatibility of the label format with the print head of your labeller before placing the order.

5. Selection tips and variants of interest

Select the version with process indicator when your traceability protocol requires checking at a glance that the load has been subjected to the steam sterilisation cycle, a common requirement in critical load validation. For intensive workflow, consider provisioning by box of 12,000 units together with the labeller Ref. 35980, optimising cost per load and service storage. Remember to periodically check the condition of your labeller’s inking system to maintain sharp and legible printing, and store the labels in a cool, dry place, protected from direct sunlight. For institutional purchases or tenders, consult your Cahnos technical-commercial advisor for special conditions and supply lead times.

Additional information

Device type

No medical device

Manufacturer reference

35984

Product type

Self-adhesive steam label with process indicator, 2 lines

Compatibility

Labeller ref. 35980

Printing configuration

First line: 3 alphabetic digits + 11 numbers; second line: 14 numbers

Sterilisation

Steam (autoclave)

Process indicator

Class 1, ISO 11140-1

Colour change

From pink (original) to brown after the cycle

Adhesive backing

Double adhesive

Ink

Non-toxic

Latex

Latex-free

Presentation

Box of 12,000 units (24 rolls of 500 labels)

Unit of sale

Box of 12,000 units

EAN

8034049914648

Classification

Not a medical device

Application

Identification and traceability of loads in steam sterilisation