Description
2-line steam labels – The traceability consumable for your Sterilisation Centre
1. Product Presentation
The 2-line steam labels (Ref. 35984) are the reference consumable for clear, permanent and auditable identification of each load processed in sterilisation services. Designed for use with the labeller Ref. 35980, these self-adhesive labels ensure sharp marking of dates, batches and operator codes, reinforcing traceability and document control in operating theatres, sterilisation centres (SEC), dental clinics and high-turnover hospital areas.
Its integrated process indicator adds a differential value: it allows visual confirmation, without additional equipment, that the package has completed the steam sterilisation cycle, contributing to patient safety and regulatory compliance of the service.
2. Technical Explanation
These labels are designed for use with the manual labeller Ref. 35980, which transfers ink via its printing system onto the label surface with each press. The first print line can display up to 3 alphabetic digits + 11 numbers, while the second line supports 14 numbers, allowing orderly recording of the sterilisation date, expiry date, batch number and steriliser number.
The label incorporates a steam process indicator (Class 1, ISO 11140-1): after the sterilisation cycle is completed, the indicator undergoes an irreversible colour change, from its original pink colour to brown, confirming at a glance that the load has been exposed to the sterilising agent. Its double adhesive backing ensures stable fixation during handling and storage of the processed material, and its ink is non-toxic and latex-free.
3. Technical Specifications
The main technical features of this consumable are detailed below:
| Brand | |
| Manufacturer reference | 35984 |
| Compatible equipment reference | Labeller Ref. 35980 |
| Product type | Self-adhesive steam label with process indicator, 2 print lines |
| First print line | Up to 3 alphabetic digits + 11 numbers |
| Second print line | Up to 14 numbers |
| Sterilisation method | Steam (autoclave) |
| Process indicator | Steam, Class 1 according to ISO 11140-1 |
| Colour change | From original pink to brown after the cycle |
| Adhesive backing | Double adhesive |
| Ink | Non-toxic |
| Latex | Latex-free |
| Sales unit | Box of 12,000 units (24 rolls of 500 labels) |
| EAN | 8034049914648 |
| Device type | Not a medical device |
4. Equivalences and Cross-References
This reference is complemented by the brand’s own labelling system: the natural application equipment is the steam labeller Ref. 35980. For load identification in three-line formats with process indicator, Cahnos also offers DUPLEX labels of 29 × 28 mm for manual labellers (Ref. 2712), along with variants without indicator (Refs. 27141 and 2713) and the application equipment Ref. 273 with its inking replacement Ref. 187. Always verify the compatibility of the label format with the print head of your labeller before placing the order.
5. Selection tips and variants of interest
Select the version with process indicator when your traceability protocol requires checking at a glance that the load has been subjected to the steam sterilisation cycle, a common requirement in critical load validation. For intensive workflow, consider provisioning by box of 12,000 units together with the labeller Ref. 35980, optimising cost per load and service storage. Remember to periodically check the condition of your labeller’s inking system to maintain sharp and legible printing, and store the labels in a cool, dry place, protected from direct sunlight. For institutional purchases or tenders, consult your Cahnos technical-commercial advisor for special conditions and supply lead times.