Chemdye® Splat CDWA4 washing chemical indicator for automatic washer-disinfectors – Box of 200 units

66,66 €

Chemdye® Splat CDWA4 washing chemical indicator for quality control in automatic washer-disinfectors and ultrasonic washers. Residue test with a 70 x 30 mm synthetic support and a very high challenge fuchsia stain that verifies the real effectiveness of the washing cycle for medical devices in accordance with ISO/TS 15883-5: if the wash is correct, the coloured organic substance disappears completely. Box of 200 units, latex-free, with results guide included.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CDWA4

Description

1. Introduction

The Chemdye® Splat CDWA4 washing chemical indicator is the professional reference solution for verifying that your automatic washer-disinfectors actually clean medical instruments. Designed for sterilisation units, operating theatres, endoscopy units and reprocessing services, this residue test provides a quick, objective and documentable visual check of the effectiveness of each cycle, so that only demonstrably clean material is sterilised. At Cahnos, we supply it in a box of 200 units, ready to integrate into your quality assurance programme.

2. Technical explanation

The CDWA4 indicator consists of a synthetic support of 70 x 30 mm, stable at disinfection temperatures, on which a mixture of coloured natural components (proteins, carbohydrates, fatty acids and dyes) is deposited, simulating the dirt embedded in instruments. The stain, fuchsia in colour with a very high challenge level, is placed in the load or on the indicator holder and subjected to the same washing cycle as the real material. At the end of the process, visual inspection determines the result: if the fuchsia organic substance has been completely removed, the wash has been effective; if the stain persists in whole or in part, the cycle has not achieved the necessary cleaning and the process must be reviewed (detergent, temperature, time, pressure or mechanical operation). The stain is non-toxic, dissolves with most cleaning agents and is carried away with the washing fluid. This method makes it possible to detect all factors affecting the cleaning result, both in washer-disinfectors and in ultrasonic washers.

3. Technical Specifications

Property Specification
Model CDWA4 (Chemdye® Splat)
Type Chemical indicator for washing residues (cleaning test)
Dimensions 70 x 30 mm (approx.)
Support Temperature-stable synthetic sheet
Initial colour Fuchsia
Challenge level Very high
Compatibility Automatic washer-disinfectors and ultrasonic washers (frequencies ≥ 35 kHz and temperatures between 30 °C and 70 °C)
Interpretation Complete removal of the fuchsia organic substance = correct cleaning
Regulatory standard ISO/TS 15883-5:2005 · ISO 13485:2016 · NS-EN ISO 13485:2016
Latex-free Yes
Accessory Chemdye® indicator holder, reference CDWAH
Presentation Box of 200 units with results guide

4. Equivalences and Cross-References

The CDWA4 belongs to the Chemdye® washing indicator family from the manufacturer Terragene (Pergut Medical group), the same cleaning test family used by the main European and American suppliers. In the international market it is identified under the manufacturer’s code CDWA4, and may appear at some distributors under the internal number C1-CDS (Duraline Systems); the indicator holder accessory is identified as CDWAH. This test shares the standard and control philosophy with the rest of the processing verification family available at Cahnos: the TOSI® test for general surgical instruments (ref. 11100120), the TOSI®-LumCheck for rigid cannulated instruments (ref. 20100250), the TOSI®-FlexiCheck for flexible endoscopes (ref. 2024025), the HemoCheck-S for detection of blood residues (ref. 6706712), the SonoCheck® for ultrasonic washers (ref. 30550300) and the Pro1 Micro® protein test (ref. PR01).

5. Selection tips and variants of interest

For routine monitoring of automatic washer-disinfectors for medical devices, choose the Chemdye® Splat CDWA4 indicator; its very high challenge offers a high guarantee of good washing performance in every cycle. If you also have ultrasonic washers, the CDWA4 is also valid for frequencies equal to or greater than 35 kHz and temperatures from 30 to 70 °C, and can be complemented with the SonoCheck® test (ref. 30550300) to verify cavitation. For more demanding control of articulated or cannulated instruments, consider the TOSI® (ref. 11100120) and TOSI®-LumCheck (ref. 20100250) process tests, and to confirm the absence of blood or protein residues on surfaces and manually washed material, combine with HemoCheck-S (ref. 6706712) and Pro1 Micro® (ref. PR01). It is recommended to purchase the CDWAH indicator holder to fix the test in the load, and to record the results of each control as evidence of compliance within the quality assurance programme based on ISO/TS 15883-5.

Additional information

Model

CDWA4 (Chemdye® Splat)

Product type

Chemical indicator for washing residues (cleaning test)

Dimensions

70 x 30 mm

Support

Temperature-stable synthetic sheet

Initial colour

Fuchsia

Challenge level

Very high

Compatibility

Automatic washer-disinfectors and ultrasonic washers (≥ 35 kHz, 30–70 °C)

Regulatory standard

ISO/TS 15883-5:2005 · ISO 13485:2016

Presentation

Box of 200 units with results guide

Manufacturer

Terragene / Pergut Medical

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Chemdye® Splat CDWA4 washing chemical indicator for automatic washer-disinfectors – Box of 200 units”

Your email address will not be published. Required fields are marked *