Description
1. Commercial Introduction
The large model sterilisation container is the robust and reliable solution for the sterilisation, storage and safe transport of surgical instruments in sterilisation departments, operating theatres and instrumentation services. With its two integrated filters and its non-perforated base, it ensures correct steam penetration and maintains the sterile barrier of the contents until the moment of use. All versions are autoclavable up to 134 °C and 2.2 bar.
2. Technical explanation of the equipment
This standard large-format container combines a 580 x 280 mm body with a non-perforated base and a lid with a double-filter system, ensuring the exchange of the sterilising agent during the autoclave cycle and the subsequent sealing of the load. The system is supplied complete with 1 paper filter and its filter holder, ready for immediate use in the processing of surgical sets. Its design allows loads to be stacked and handled safely, maintaining sterility integrity during storage and transport.
3. Technical Specifications
The standard container with double filter and non-perforated base is available in several heights and two colours (grey and red), allowing the capacity to be adapted to each type of load and, in the case of the red finish, facilitating visual coding by speciality or priority of use.
Available references
| Reference | Size | Colour | Sales unit | Details |
|---|---|---|---|---|
| GM37100 | 100 mm | Grey | 1 unit | Large model: 580 x 280 mm · Height: 100 mm · Non-perforated base · 2 filters · Colour: grey |
| GM37101 | 135 mm | Grey | 1 unit | Large model: 580 x 280 mm · Height: 135 mm · Non-perforated base · 2 filters · Colour: grey |
| GM37102 | 150 mm | Grey | 1 unit | Large model: 580 x 280 mm · Height: 150 mm · Non-perforated base · 2 filters · Colour: grey |
| GM37103 | 200 mm | Grey | 1 unit | Large model: 580 x 280 mm · Height: 200 mm · Non-perforated base · 2 filters · Colour: grey |
| GM37104 | 260 mm | Grey | 1 unit | Large model: 580 x 280 mm · Height: 260 mm · Non-perforated base · 2 filters · Colour: grey |
| GM37110 | 100 mm | Red | 1 unit | Large model: 580 x 280 mm · Height: 100 mm · Non-perforated base · 2 filters · Colour: red |
| GM37112 | 150 mm | Red | 1 unit | Large model: 580 x 280 mm · Height: 150 mm · Non-perforated base · 2 filters · Colour: red |
Standard containers are supplied with 1 paper filter and its filter holder. All containers are autoclavable up to a maximum of 134 °C and 2.2 bar.
| Characteristic | Specification |
|---|---|
| Format | Large model: 580 x 280 mm |
| Depth | Non-perforated |
| Filters | 2 filters (supplied with 1 paper filter and filter holder) |
| Available colours | Grey and red |
| Available heights | 100, 135, 150, 200 and 260 mm |
| Sterilisation | Autoclavable up to 134 °C and 2.2 bar |
| Manufacturer | GIMA |
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | I |
| CND | S9099 |
Note: this product is not marketable in Germany.
4. Equivalences and Cross-References
Within the filter container family, all references share the same large format (580 x 280 mm), non-perforated base and double-filter system, differing only in height and colour. The grey versions (GM37100 to GM37104) cover heights from 100 to 260 mm, while the red versions (GM37110 and GM37112) offer heights of 100 and 150 mm for applications requiring rapid visual identification. A validated equivalence table between this container and models from other manufacturers has not been found in reliable sources; for any replacement or tender specification, it is recommended to consult the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
Select the container height according to the volume of instruments to be processed: heights of 100 and 135 mm are suitable for light loads or small sets, while 150, 200 and 260 mm allow bulkier instruments or larger sets to be accommodated. If your department uses a colour code by speciality or priority level, the red finish (GM37110 and GM37112) facilitates immediate identification of the set. Remember to replace the paper filter in each cycle to maintain the sterile barrier, and complement the system with the accessories and consumables for instrument containers available in the Cahnos catalogue.


















Reviews