We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reusable PTFE (Teflon) filter Ø 19 cm for instrument containers and sterilisation | Ref. 37327

188,10 €

Reusable PTFE (Teflon) filter, 19 cm in diameter, designed as a reusable microbial barrier for sterilisation systems in instrument containers. Its Teflon membrane of 0.75 mm thickness with a pore width of approximately 2.5 µm allows the sterilising agent to pass through and maintains the sterile barrier during storage and transport. Designed for prolonged use, it withstands up to 1,200 sterilisation cycles, making it a cost-effective and sustainable alternative to single-use filters. Class I medical device, factory reference Ref. 37327 (SKU GM37327), sales unit 1 unit. Ideal for sterilisation centres, operating theatres and instrumentation services seeking to reduce consumable consumption without compromising safety.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM37327

Description

1. Commercial Introduction

Ensure the sterility of your surgical instruments with the reusable PTFE (Teflon) filter, Ø 19 cm, a long-lasting microbial barrier solution designed for sterilisation centres, operating theatres, clinics and practices that work with instrument containers and ventilated sterilisation systems. Its reusable design drastically reduces the consumption of disposable filters, with a performance of up to 1,200 sterilisation cycles, resulting in significant cost savings and a lower environmental impact, without compromising process safety.

2. Technical explanation of the product and procedure

Ventilation filters for sterilisation are placed over the valve or ventilation opening of the instrument container. Their function is twofold: during the sterilisation cycle they allow the sterilising agent to enter and exit, and once the process is complete they prevent the passage of microorganisms, maintaining the sterility of the contents during storage and transport.

The PTFE membrane (polytetrafluoroethylene, commercially known as Teflon) is a hydrophobic material with great chemical and thermal stability, ideal for withstanding repeated steam sterilisation cycles without degrading. With a thickness of 0.75 mm and an approximate pore width of 2.5 µm, it offers effective filtration of particles and microorganisms while maintaining proper vapour permeability. Being reusable, it must undergo the same sterilisation process as the instruments and be replaced only when damage, blockages or loss of membrane integrity are detected.

3. Technical Specifications

The filter has a diameter of 19 cm (190 mm) and is made of PTFE (Teflon), with a membrane thickness of 0.75 mm and an approximate pore width of 2.5 µm.

Product data

Manufacturer GIMA
Manufacturer reference 37327
SKU Cahnos GM37327
Sales unit 1 pc
Material Reusable PTFE (Teflon)
Diameter 19 cm (Ø 190 mm)
Thickness 0.75 mm
Pore width Approx. 2.5 µm
Sterilisation cycles Up to 1,200 cycles
Use Reusable
Device type Medical device
Device class I
CND S9099
EAN 8023279373271

4. Equivalences and Cross-References

This product corresponds to the official factory reference Ref. 37327, marketed by Cahnos under the SKU GM37327. There is no officially validated equivalence table with references from other manufacturers for this model; comparisons with PTFE filters from other brands must always verify the diameter (19 cm), membrane thickness (0.75 mm) and pore width (approx. 2.5 µm), as well as compatibility with the containment system or autoclave used. Consult the technical department of Cahnos before replacing this filter with an equivalent in tenders or procurement documents.

5. Selection tips and variants of interest

  • Check the diameter: this filter is 19 cm in diameter; confirm that it matches the valve or ventilation opening of your container or system before placing the order.
  • Periodic inspection: as it is reusable, check the integrity of the PTFE membrane after each cycle. Replace the filter if you notice tears, deformations, blockages or loss of the barrier.
  • Process compatibility: due to its hydrophobic nature and thermal stability, PTFE is suitable for steam sterilisation cycles; confirm the recommended parameters of your autoclave.
  • Cost-effectiveness: with up to 1,200 service life cycles, this reusable filter optimises the cost per cycle compared to disposable filters, ideal for high sterilisation volumes.

Additional information

Manufacturer reference

37327

Material

PTFE (Teflon)

Diameter

19 cm (Ø 190 mm)

Thickness

0.75 mm

Pore width

Approx. 2.5 µm

Sterilisation cycles

Up to 1,200 cycles

CND code

S9099

EAN

8023279373271

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Tipo uso

Reusable

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Reusable PTFE (Teflon) filter Ø 19 cm for instrument containers and sterilisation | Ref. 37327”

Your email address will not be published. Required fields are marked *