Description
1. Introduction
The Barrier System container with valve and perforated bottom (ref. GM37240 and family) is the recommended solution for sterilisation units and operating theatres seeking a robust, reusable instrument containment system for continuous use. Its integrated valve design eliminates the need to replace filters between cycles, simplifying logistics in the sterilisation area and reducing consumables.
Available in blue and in two sizes (medium and large), it adapts to different surgical instrument load volumes. It is a class I medical device and is marketed by Cahnos. For large orders you can request a quote.
2. Technical explanation of the equipment and procedure
This container belongs to the Barrier System, a preferred configuration when continuous use of containers is required, as it avoids filter replacement after each cycle. The valve remains closed during storage and opens during the sterilisation phase to allow steam to escape, ensuring penetration of the sterilising agent and the subsequent preservation of instrument sterility.
The perforated bottom facilitates steam circulation through the load and enables a considerably faster sterilisation process (approximately half the time compared with a non-perforated bottom), optimising sterilisation unit performance. The container also incorporates a chrome-plated locking pin at the bottom that ensures the lid remains closed during cycles and handling.
3. Technical Specifications
All containers in this range are autoclavable up to a maximum of 134 °C and 2.2 bar. They are supplied per unit (1 pc).
General product data
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 pc (unit) |
| Device type | Medical device (Medical device) |
| Device class | I |
| System | Barrier System with valve |
| Depth | Perforated |
| Colour | Blue |
| Sterilisation | Autoclavable max. 134 °C and 2.2 bar |
| Closure | Chrome-plated lower locking pin |
Available references
| Reference | Size | Sales unit | Details |
|---|---|---|---|
| GM37240 | medium h 100 mm | 1 pc | Medium model: 465 x 280 mm · Height: 100 mm · Perforated bottom · Barrier System with valve · Colour: blue |
| GM37241 | medium h 135 mm | 1 pc | Medium model: 465 x 280 mm · Height: 135 mm · Perforated bottom · Barrier System with valve · Colour: blue |
| GM37242 | medium h 150 mm | 1 pc | Medium model: 465 x 280 mm · Height: 150 mm · Perforated bottom · Barrier System with valve · Colour: blue |
| GM37243 | medium h 200 mm | 1 pc | Medium model: 465 x 280 mm · Height: 200 mm · Perforated bottom · Barrier System with valve · Colour: blue |
| GM37280 | large h 100 mm | 1 pc | Large model: 580 x 280 mm · Height: 100 mm · Perforated bottom · Barrier System with valve · Colour: blue |
| GM37281 | large h 135 mm | 1 pc | Large model: 580 x 280 mm · Height: 135 mm · Perforated bottom · Barrier System with valve · Colour: blue |
| GM37282 | large h 150 mm | 1 pc | Large model: 580 x 280 mm · Height: 150 mm · Perforated bottom · Barrier System with valve · Colour: blue |
| GM37283 | large h 200 mm | 1 pc | Large model: 580 x 280 mm · Height: 200 mm · Perforated bottom · Barrier System with valve · Colour: blue |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table that cross-references this reference 1:1 with other brands. Sterilisation container systems from other manufacturers (e.g. Aesculap, KLS Martin or the AISI 304 stainless steel containers from surgical distribution) are comparable only by category and are not directly interchangeable: each manufacturer uses its own valve, filter, closure and record systems. Before any replacement or use in tenders, the material, closure system, bottom (perforated or non-perforated), dimensions and regulatory classification must be validated with the Cahnos technical department.
Within the range itself, all references GM37240-GM37243 and GM37280-GM37283 share the same Barrier System with valve and perforated bottom, differing only in size (medium or large) and height (100, 135, 150 and 200 mm).
5. Selection tips and variants of interest
Select the medium model (465 x 280 mm) for standard-size instrument loads, or the large model (580 x 280 mm) when you need greater usable surface area and volume. The height (100, 135, 150 or 200 mm) should be chosen according to the volume and dimensions of the instruments to be sterilised.
Thanks to the perforated bottom and the Barrier System valve, this range is especially suitable for sterilisation units with intensive rotation, where reduced cycle time and the elimination of filter changes represent a significant operational improvement. Remember that all containers are autoclavable up to 134 °C and 2.2 bar and that this product is not marketed in Germany.