Description
1. Product Presentation
The Medium Cannulated Cleaning Brush of 305 x 6 mm (Ref. TR350429-3, SKU 123TR3504290) is the essential tool for the maintenance and decontamination of cannulated medical instruments in sterilisation centres, operating theatres, dental clinics, veterinary centres and reprocessing units. Its combination of polyamide bristles and braided stainless steel guide wire guarantees deep cleaning of the interior of devices without damaging their internal walls, prolonging the useful life of your instrument inventory and ensuring compliance with the most demanding hygiene and biosafety protocols. A reliable ally for the safety of patients and healthcare personnel.
2. Technical explanation of the product and procedure
Cannulated devices, such as suction cannulas, surgical cannulas, tubes and tubular instruments, accumulate organic debris and biofilms in their lumen that surface washing does not remove and that prevent the effective action of the sterilising agent. This brush allows mechanical brushing of the interior of the lumen, an essential preliminary step in the decontamination chain: pre-cleaning, washing and steam sterilisation in an autoclave.
The braided stainless steel guide wire provides flexibility, chemical resistance and durability, allowing the bristles to be guided through conduits up to 305 mm in length. The polyamide bristles offer a firm but non-abrasive brushing that respects the integrity of the instrument’s internal walls and withstands repeated cycles of steam sterilisation. It is a reusable product, classified as a class I medical device with CE marking and suitable for reprocessing in an autoclave.
3. Technical specifications and reference tables
The following table lists the reference technical features of this brush:
| Characteristic | Specification |
|---|---|
| Reference | TR350429-3 (SKU 123TR3504290) |
| Total length (wire) | 305 mm |
| Bristle diameter (working) | 6 mm |
| Bristle length | 20 mm |
| Bristle material | Polyamide (resistant to steam sterilisation) |
| Wire material | Braided stainless steel |
| Decontamination | Washable and sterilisable by steam (autoclave) |
| Application | Interior cleaning of medium-calibre cannulated devices |
| Reusable | Yes |
| Classification | Class I medical device with CE marking |
| Presentation | Box of 3 units |
Comparative table of the nylon cannulated brush family (instrument cleaning series):
| Reference | Bristle diameter | Bristle length | Wire length | Units per box |
|---|---|---|---|---|
| TR350429-3 (this product) | 6 mm | 20 mm | 305 mm | 3 |
| TR350109-3 | 2.3 mm | 20 mm | 300 mm | 3 |
| TR350232-3 | 3 mm | 20 mm | 300 mm | 3 |
| TR350354 | 5 mm | 20 mm | 300 mm | 3 |
| TR360231-3 | 2.5 mm | — | 610 mm | 3 |
| TR150221-3 | 5 mm | — | 610 mm | 3 |
| 45905 | 1.25 mm | 20 mm | 508 mm | 3 |
4. Equivalences and Cross-References
This brush belongs to the series of brushes for manual cleaning of cannulated instruments from the manufacturer Pergut Medical, with reference TR350429-3 being the mediana variant of 6 mm diameter and 305 mm guide wire, interchangeable with its equivalent commercial reference in orders and replacements. Functionally, it corresponds to the channel cleaning brushes from manufacturers such as STERIS, the CISA Brasile brush line and the brushes for cannulated instruments from Igaltex, all based on the same principle of bristles mounted on a braided shaft for dragging debris in lumens with direct or curved access.
Within the Cahnos catalogue, it is part of a complete range that includes the medium models of 2.3 mm (TR350109-3), 3 mm (TR350232-3) and 5 mm (TR350354), the long series of 610 mm (TR360231-3, TR150221-3, TR150483-3 and TR160617-3), the large volume variant of 9 mm in a box of 50 units (FLEX004), those with rigid guide wire (refs. 4034, 4035 and 241045) and those specific for cleaning endoscope valves (45918). For validation of exact equivalences with the references currently used by your centre, our technical-commercial department will advise you without obligation.
5. Selection tips and variants of interest
To choose the appropriate brush, select a bristle diameter slightly smaller than the internal diameter of the lumen to be cleaned, so that the bristles press gently against the walls without jamming, and a guide wire length that covers the total depth of the channel. The 6 mm model (TR350429-3) is ideal for cannulas and medium-calibre instruments, such as suction tubes and components of intermediate-section equipment. If the lumen has a reduced passage, opt for the 2.3 mm (TR350109-3), 3 mm (TR350232-3) or 1.25 mm (45905) variants; for larger calibres, the 9 mm models (FLEX004) or the long 610 mm series; and for rigid components, the rigid guide wire range (4034, 4035 and 241045).
After each shift, wash the brush and sterilise it by steam in an autoclave following the centre’s procedure. All models in the family are reusable and comply with the standard protocols of sterilisation centres. For replacement orders, purchasing centres and special conditions by volume, consult our technical-commercial department at Cahnos.





Reviews
There are no reviews yet.