Description
1. Introduction
The self-adhesive mixed pouch BOP DI 90×230 mm from Pergut Medical (Sterimed Group / SPS Medical) is the packaging solution that every sterilisation department needs for small and medium instruments: forceps, scissors, small minor surgery sets, dental material and compact medical devices. It is a peelable mixed pouch with a self-adhesive band closure that allows sealing by simple pressure, without the need for a heat sealer, streamlining the workflow in hospitals, clinics, laboratories and practices.
Manufactured with medical-grade materials and provided with a dual chemical process indicator, it offers the safety, traceability and regulatory compliance required for professional medical packaging, maintaining the sterility of devices up to the point of use.
2. Technical Explanation
This peelable mixed pouch is a preformed sterile barrier system (SBS) of mixed configuration, consisting of two distinct faces: a face of Premium medical-grade paper of 60 g/m² (ISO 536), developed specifically for steam sterilisation and validated according to EN 868-3, with a surface treatment that provides greater mechanical strength and better fibre release; and a face of transparent laminated film coloured lilac (polyester PET 12 µm + polypropylene PP 38 µm) that allows visual verification of the contents without opening the pouch.
The closure system is a self-adhesive band: sealing is achieved by applying pressure to the paper, without generating residues or damaging the seal. Under the seals it incorporates 2 chemical process indicators (class 1, according to ISO 11140-1) that change colour when the cycle is complete: steam (pink → brown) and ethylene oxide (blue → green); the pouch is also compatible with formaldehyde sterilisation.
The opening is peelable and aseptic, without tearing or curling of the film. It is a single-use pouch (do not re-sterilise), free from natural latex, compliant with EN 868-5 and ISO 11607-1/2 and classified as a class I medical device (accessory) with CE marking according to Regulation (EU) 2017/745 (MDR). It is not suitable for gamma irradiation or for plasma/hydrogen peroxide.
3. Technical Specifications
Technical data verified against the official technical data sheet of the BOP® DI material from SPS Medical (FT-S2A_01/FR) and the manufacturer’s official catalogue.
| Characteristic | Detail |
|---|---|
| Reference Cahnos (SKU / official SPS Medical code) | S2A090X230 |
| Official Pergut Medical reference (Spain) | 311250 |
| Measurements | 90 × 230 mm |
| Packaging type | Self-adhesive peelable mixed pouch (preformed sterile barrier), without heat sealer |
| Paper face | Premium medical-grade paper 60 g/m² (ISO 536), printed, validated according to EN 868-3, with adhesive band |
| Film face | Lilac laminated film: polyester (PET) 12 µm + polypropylene (PP) 38 µm |
| Chemical indicators | 2 class 1 process indicators (ISO 11140-1): steam (pink → brown) and ethylene oxide (blue → green), printed on the paper under the seals |
| Closure system | Self-adhesive strip, sealed by simple pressure on the paper |
| Sterilisation methods | Steam, ethylene oxide (EO) and formaldehyde |
| Not suitable for | Gamma irradiation or hydrogen peroxide plasma (H2O2) |
| Seal strength | ≥ 1.5 N/15 mm (EN 868-5) |
| Regulatory standard | EN 868-5, EN ISO 11607-1 and 11607-2 |
| Regulatory classification | Class I medical device (accessory), CE marked, Regulation (EU) 2017/745 (MDR) |
| Recommended filling | Maximum 2/3 of the internal capacity of the pouch |
| Shelf life / storage | 5 years from manufacture; store in a cool, dry place (10–30 °C, 30–60 % RH), protected from direct light |
| Latex / TSE-BSE | Free from natural latex; compliant with EMEA/410/01 |
| Presentation | Box of 200 units (factory packaging: 2,000 units/box) |
| Brand / origin | Pergut Medical (Sterimed Group / SPS Medical) · manufactured in France |
BOP DI self-adhesive pouch size range (official Pergut Medical / SPS Medical catalogue)
| Pergut reference | Dimensions (mm) | Units / box | SKU Cahnos |
|---|---|---|---|
| 311240 | 60 × 130 | 4,200 | S2A060X130 |
| — | 70 × 230 | 2,000 | S2A070X230 |
| 311249 | 90 × 203 | 2,000 | S2A090X203 |
| 311250 (this product) | 90 × 230 | 2,000 | S2A090X230 |
| 311253 | 130 × 254 | 2,000 | S2A130X254 |
| 311254 | 130 × 356 | 2,000 | S2A130X356 |
| 311255 | 140 × 285 | 1,000 | Consult |
| 311256 | 200 × 330 | 1,000 | S2A200X330 |
| 311257 | 250 × 400 | 1,000 | S2A250X400 |
| 311258 | 300 × 390 | 1,000 | S2A300X390 |
| 311259 | 300 × 450 | 1,000 | S2A300X450 |
4. Equivalences and Cross-References
Exact reference equivalence: the SKU Cahnos S2A090X230 literally matches the official manufacturer code of SPS Medical (Sterimed Group) for the self-adhesive BOP DI pouch of 90 × 230 mm, verified against the manufacturer’s official catalogue and the technical data sheet of the BOP DI series: same family, same dimensions, same material. It also corresponds to reference 311250 of the BOP DI size programme in the Pergut Medical (Spain) catalogue: same family and same dimensions; however, the 3112xx numbering could not be fully independently verified in public sources during this review, so it is recommended to confirm with Pergut Medical before use in technical documents or tenders.
Functional category comparison (not 1:1 interchangeable): there is currently no cross-reference equivalence table validated by the manufacturer that equates this reference with codes from other manufacturers (for example, ELINE mixed self-adhesive pouches, Bolsaplast or other distributor self-sealing ranges). Any cross-reference with other brands must be treated as comparable at category level: before proposing a substitution in a tender, verify against the corresponding manufacturer’s technical data sheet and IFU the exact dimensions, paper weight, available indicators, presentation and regulations.
Caution within the brand itself: Pergut’s self-adhesive family also includes the BOP SI lines (simple steam indicator only) and BOP TI (heat seal closure, without adhesive band), as well as gusseted pouches and VIEWPACK self-adhesive pouches: these are different products with a different closure system or different process indication and should not be treated as direct equivalents without validating the closure procedure and indicators. Consult the technical department before replacing references in specifications or contracts.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Size selection: the 90 × 230 mm format is ideal for small and medium instruments: forceps, scissors, small minor surgery sets and medical consumables. Always measure the device and leave at least one third of the pouch free.
- Filling rule: do not fill the pouch more than two thirds of its capacity to allow proper circulation of the sterilising agent and drying; avoid sharp folds that could damage the paper or the seal.
- Without a sealing machine: the self-adhesive strip allows sealing by simple pressure. If you have a validated heat sealer, you may consider the flat mixed pouches BOP TI from the same manufacturer as a functional alternative.
- Family variants: for more compact pieces, the 60 × 130 mm (S2A060X130) or the 70 × 230 mm (S2A070X230); for a similar format, the 90 × 203 mm (S2A090X203); for larger instruments, the 130 × 254 mm (S2A130X254), 130 × 356 mm (S2A130X356), 200 × 330 mm (S2A200X330), 250 × 400 mm (S2A250X400), 300 × 390 mm (S2A300X390) or 300 × 450 mm (S2A300X450).
- Cycle verification: always check the colour change of the chemical indicators (pink → brown in steam; blue → green in EO) at the end of sterilisation before validating the process, and record the batch, date and contents on the labelling.
- Good practices: store the boxes in a cool, dry place (10–30 °C, 30–60 % relative humidity), protected from direct light; respect the single-use principle (do not re-sterilise) and place the pouches in the autoclave face to face (film to film or paper to paper).




Reviews
There are no reviews yet.