Description
1. Introduction
The 60 × 130 mm BOP DI self-adhesive mixed pouch from Pergut Medical (Sterimed Group / SPS Medical) is the packaging solution that every sterilisation department needs for small instruments: burs, files, handpieces, dental and aesthetic material, small medical consumables and compact devices. It is a peelable mixed pouch with a self-adhesive strip closure that is sealed by simply applying pressure, without the need for a heat sealer, which speeds up the workflow in hospitals, clinics, practices and laboratories.
Manufactured from medical-grade materials and fitted with a dual chemical process indicator, it offers the safety, traceability and regulatory compliance required for professional healthcare packaging, maintaining the sterility of devices up to the point of use. It is supplied in a box of 4,200 units, the most efficient option for departments with a high daily packaging volume.
2. Technical Explanation
This peelable mixed pouch is a preformed sterile barrier system (SBS) of mixed configuration consisting of two distinct faces: a 60 g/m² Premium medical-grade paper face (ISO 536), developed specifically for steam sterilisation and validated to EN 868-3, with a unique surface treatment that provides greater mechanical strength and better fibre release; and a transparent laminated film face coloured lilac (polyester PET 12 µm + polypropylene PP 38 µm) that allows visual verification of the contents without opening the pouch.
The closure system is a self-adhesive strip: sealing is achieved by applying pressure to the paper, without generating waste or damaging the seal. Beneath the seals it incorporates 2 class 1 chemical process indicators (conforming to ISO 11140-1) that change colour when the cycle is complete: steam (pink → brown) and ethylene oxide (blue → green); the pouch is also compatible with formaldehyde sterilisation.
Opening is peelable and aseptic, without tearing or curling of the film and with reduced noise. It is a single-use pouch (do not re-sterilise), free from natural latex, conforming to EN 868-5 and ISO 11607-1/2 and classified as a class I medical device (accessory) with CE marking under Regulation (EU) 2017/745 (MDR). It is not suitable for gamma irradiation or for plasma/hydrogen peroxide.
3. Technical Specifications
| Characteristic | Detail |
| Reference Cahnos (SKU / official SPS Medical code) | S2A060X130 |
| Official Pergut Medical reference (Spain) | 311240 |
| Measurements | 60 × 130 mm |
| Packaging type | Self-adhesive peelable mixed pouch (preformed sterile barrier), without heat sealer |
| Paper face | Premium medical-grade paper 60 g/m² (ISO 536), printed, validated according to EN 868-3, with adhesive band |
| Film face | Lilac laminated film: polyester (PET) 12 µm + polypropylene (PP) 38 µm |
| Chemical indicators | 2 class 1 process indicators (ISO 11140-1): steam (pink → brown) and ethylene oxide (blue → green), printed on the paper beneath the seals |
| Closure system | Self-adhesive band, pressure sealing on the paper |
| Sterilisation methods | Steam, ethylene oxide (EO) and formaldehyde |
| Not suitable for | Gamma irradiation or hydrogen peroxide plasma (H2O2) |
| Seal strength | ≥ 1.5 N/15 mm (EN 868-5) |
| Regulatory standard | EN 868-5, EN ISO 11607-1 and 11607-2 |
| Regulatory classification | Class I medical device (accessory), CE marked, Regulation (EU) 2017/745 (MDR) |
| Recommended filling | Maximum 2/3 of the internal capacity of the pouch |
| Shelf life / storage | 5 years from manufacture; store in a cool, dry place (10–30 °C, 30–60 % RH), protected from direct light |
| Latex / TSE-BSE | Free from natural latex; compliant with EMEA/410/01 |
| Presentation | Box of 4,200 units |
| Brand / origin | Pergut Medical (Sterimed Group / SPS Medical) · manufactured in France |
Size programme of BOP DI self-adhesive pouches (official Pergut Medical / SPS Medical catalogue):
| Pergut reference | Dimensions (mm) | Units / box | SKU Cahnos |
| 311240 (this product) | 60 × 130 | 4,200 | S2A060X130 |
| — | 70 × 230 | 2,000 | S2A070X230 |
| 311249 | 90 × 203 | 2,000 | S2A090X203 |
| 311250 | 90 × 230 | 2,000 | S2A090X230 |
| 311253 | 130 × 254 | 2,000 | S2A130X254 |
| 311254 | 130 × 356 | 2,000 | S2A130X356 |
| 311255 | 140 × 285 | 1,000 | Consult |
| 311256 | 200 × 330 | 1,000 | S2A200X330 |
| 311257 | 250 × 400 | 1,000 | S2A250X400 |
| 311258 | 300 × 390 | 1,000 | S2A300X390 |
| 311259 | 300 × 450 | 1,000 | S2A300X450 |
4. Equivalences and Cross-References
Exact reference equivalence: the Cahnos SKU S2A060X130 literally matches the official code of the manufacturer SPS Medical (Sterimed Group) for the BOP DI self-adhesive pouch of 60 × 130 mm, verified against the manufacturer’s official catalogue and the technical data sheet of the BOP DI series: same family, same dimensions, same material and same presentation (box of 4,200 units). It also corresponds to reference 311240 in the BOP DI size programme of the official Pergut Medical (Spain) catalogue: same family, same dimensions and same presentation; however, the 3112xx numbering could not be fully independently verified in public sources during this review, so it is recommended to confirm with Pergut Medical before use in technical documents or tenders.
Functional category comparison (not 1:1 interchangeable): there is currently no cross-reference equivalence table validated by the manufacturer that equates this reference with codes from other manufacturers (for example, ELINE mixed self-adhesive pouches, Bolsaplast or other distributor self-sealing ranges). Any cross-reference with other brands should be treated as comparable at category level: before proposing a substitution in a tender, verify against the corresponding manufacturer’s technical data sheet and IFU the exact dimensions, paper weight, available indicators, presentation and regulations.
Caution within the brand itself: Pergut’s self-adhesive family also includes the BOP SI lines (steam-only single indicator) and BOP TI (heat-seal closure, without adhesive strip), as well as gusseted pouches and VIEWPACK self-adhesive pouches: these are different products with a different closure system or different process indication and should not be treated as direct equivalents without validating the closure procedure and indicators. Consult the technical department before replacing references in specifications or contracts.
5. Selection tips and variants of interest
Size selection: the 60 × 130 mm format is ideal for very compact instruments: burs, files, handpieces, dental and aesthetic material, needles and small medical consumables. Always measure the device and leave at least one third of the pouch free.
Filling rule: do not fill the pouch more than two thirds of its capacity to allow proper circulation of the sterilising agent and drying; avoid sharp folds that could damage the paper or the seal.
Without sealing machine: the self-adhesive strip allows sealing by simple pressure. If you have a validated heat sealer, you may consider the same manufacturer’s flat mixed BOP TI pouches as a functional alternative.
Family variants: for slightly larger items, consider the 70 × 230 mm (S2A070X230), the 90 × 203 mm (S2A090X203) or the 90 × 230 mm (S2A090X230); for medium instruments, the 130 × 254 mm (S2A130X254) and for larger packs, the 130 × 356 mm (S2A130X356), 200 × 330 mm (S2A200X330), 250 × 400 mm (S2A250X400), 300 × 390 mm (S2A300X390) or 300 × 450 mm (S2A300X450).
Cycle verification: always check the colour change of the chemical indicators (pink → brown in steam; blue → green in EO) at the end of sterilisation before considering the process valid and record batch, date and contents on the labelling.
Good practice: store the boxes in a cool, dry place (10–30 °C, 30–60 % relative humidity), protected from direct light; observe the single-use principle (do not re-sterilise) and place the pouches in the autoclave face to face (film to film or paper to paper).




Reviews