We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Biological Indicator BT20 24 h Reading for Steam – Self-contained, Geobacillus stearothermophilus 10⁵ | Box of 100 units

183,33 €

Self-contained biological indicator BT20 for the control and validation of steam sterilisation cycles (121–135 °C). Spores of Geobacillus stearothermophilus ATCC 7953 (10⁵ per vial) on a paper carrier, culture medium with pH indicator and colorimetric reading in 24 h. Ready to use: crush the ampoule, incubate in the Bionova® IC10/20 incubator (60 °C) and read the result without the need for a laboratory.

International shipping. Import duties and taxes are payable by the recipient.

Reference
BT20

You will also find it in

Description

Biological Indicator BT20 – Steam Sterilisation Control

The self-contained biological indicator BT20 is the most reliable and convenient solution for verifying the real effectiveness of your steam sterilisation cycles in pre-vacuum autoclaves (vacuum-assisted) and gravity air displacement autoclaves, in the range of 121 °C to 135 °C. By incorporating the spores and culture medium in a single ready-to-use plastic vial, it requires no laboratory facilities: in just 24 hours it confirms by colorimetry whether the process has been correct and allows the load to be released with full guarantee.

At Cahnos we make it available to you in its professional presentation of box of 100 units, with technical-commercial advice for institutional purchases, tenders, sterilisation centres and projects for equipping new sterilisation units.

How it works and why it is essential

Each self-contained BT20 vial contains a filter paper carrier inoculated with Geobacillus stearothermophilus ATCC 7953, the reference microorganism for steam processes due to its high thermal resistance, together with a glass ampoule containing tryptic soy broth (TSB) dyed with a pH indicator. After the sterilisation cycle, the ampoule is crushed with the ampoule breaker, the vial is shaken so that the medium soaks the carrier, and it is incubated at 55–62 °C (recommended: 60 °C in the Bionova® IC10/20 incubator).

If the process was effective, the spores are inactivated and the medium remains purple; if there was a failure, microbial growth acidifies the medium and it turns yellow, indicating a positive contamination result. The colour change of the reactive ink line on the label (to brown) confirms that the vial was exposed to steam. Always include a unprocessed positive control from the same batch to validate the incubation conditions: its turning yellow guarantees that negative results are reliable.

Technical specifications

Characteristic Value
Reference BT20
Sterilisation method Steam (121–135 °C)
Microorganism Geobacillus stearothermophilus ATCC 7953
Spore population 10⁵ per vial (also available 10⁶)
Spore carrier Filter paper, 7.0 mm diameter, 160 g/m²
Culture medium Tryptic soy broth (TSB) with pH indicator, 0.5–0.7 ml, purple colour
Ampoule Glass, 35.0–40.0 mm high, Ø 6.5 mm
Vial Polypropylene, 45.2 × 8.5 mm (Ø ext.)
Cap and filter Polypropylene with medical-grade paper filter
Chemical indicator Steam-reactive line on label (turns brown)
Incubation temperature 55–62 °C (recommended 60 °C)
Reading time Maximum 24 hours
D value (121 °C) ≥ 1.5 minutes (other D and Z values declared)
Period of use 2 years from manufacture
Storage 10-30 °C, 30-80 % RH, protected from light
Presentation Box of 100 units
Regulatory standard ISO 11138-1, ISO 11138-3, IRAM 37102-1, IRAM 37102-3, ISO 13485

Equivalences and cross-references

The BT20 is the original reference Bionova® BT20 from Terragene S.A., also marketed as BT20/5 (presentation of 25 units) in the international channel. On the market there are self-contained alternatives for steam with 24 h reading based on the same microorganism Geobacillus stearothermophilus, including the indicators ES00/5 or ES00/50 (GKE Steri-Record®), Steam Plus (Propper), EZTest (SPS Medical) and the series SCS-05/SporView™ (Crosstex). Our technical-commercial department can provide you with the detailed comparison with the reference your centre currently uses.

Selection tips and variants of interest

To complete your biological control system, we recommend: the dual Bionova® IC10/20 incubator, with 46 positions and colorimetric reading, specifically designed to incubate the BT20 at 60 °C; the BT family biological controls for other processes (BT10 ethylene oxide, BT30 dry heat, BT91 gas plasma, BT100 formaldehyde); Type 5 chemical integrators (IT26S, CI105) and Type 6 emulators (IT27) for steam; and Type 4 multivariable indicators (229, CD30, CD40, CD50) for the remaining methods. For institutional purchases, special conditions, supply times or tender needs, consult your technical-commercial advisor at Cahnos.

Additional information

Sterilisation method

Steam (121-135 °C)

Microorganism

Geobacillus stearothermophilus ATCC 7953

Spore population

10⁵ per vial (10⁶ available)

Spore carrier

Filter paper 7 mm, 160 g/m²

Culture medium

Tryptic soy broth (TSB) with pH indicator, 0.5-0.7 ml

Reading

24 hours (maximum)

Incubation temperature

55-62 °C (recommended 60 °C)

D value

≥ 1.5 min at 121 °C

Format

Self-contained polypropylene vial 45.2 × 8.5 mm

Presentation

Box of 100 units

Regulatory standard

ISO 11138-1, ISO 11138-3, ISO 13485, IRAM 37102-1/3

Shelf life

2 years

Storage

10-30 °C, 30-80 % RH, protected from light

Reviews

There are no reviews yet.

Be the first to review “Biological Indicator BT20 24 h Reading for Steam – Self-contained, Geobacillus stearothermophilus 10⁵ | Box of 100 units”

Your email address will not be published. Required fields are marked *