Description
1. Commercial Introduction
Keep your spirometry station always operational with this section of accessories and consumables for MIR spirometers: from the disposable FlowMIR turbine for maximum patient-to-patient hygiene, to reusable turbines, paper and plastic mouthpieces, bacterial/viral filters, the 3-litre calibration syringe and thermal paper for the Spirolab printer. It also includes the optional oximetry block: reusable Softtip® sensors and catheters in three sizes, with extension cables compatible with BCI oximeters, and transport and power solutions (cases, bags, Spirodoc belt, charger and 1.8 m micro USB cable). A range designed for respiratory medicine services, primary care, occupational medicine and pulmonary function laboratories.
2. Technical explanation of the equipment and procedure
The MIR family spirometers (Spirolab, Spirotel, Spirodoc, Spirobank, Minispir, Smart One and Smart One Oxi) measure flow and volume using a low-inertia turbine sensor: the air that the patient inhales and exhales rotates the turbine and the device calculates the parameters (FVC, FEV1, PEF, FEF25-75%, MVV…) from the rotation speed. The disposable FlowMIR turbines are factory calibrated and require no further calibration: they are attached with their integrated cardboard mouthpiece, the test is performed and they are discarded, eliminating cross-contamination and reprocessing between patients. The reusable turbines (with metal mesh) are combined with a plastic or paper mouthpiece and allow a disinfected circuit with a lower cost per test. For the volumetric quality control recommended by the ATS/ERS guidelines, the 3-litre syringe allows periodic verification of the device’s accuracy; the nasal clip, also recommended by ATS/ERS, occludes nasal leakage during the manoeuvre. In devices with the oximetry option, the reusable Softtip® catheters (Envitec RS-3222-12, BCI original) record SpO2 and pulse rate simultaneously with spirometry.
3. Technical Specifications
3.1 Consumables
| Consumable | Manufacturer reference | Presentation | Use and compatibility |
|---|---|---|---|
| Disposable FlowMIR turbine with integrated cardboard mouthpiece | 910004 (SKU 33507 / GM33507) | Individual packaging; box of 10 units and dispenser box of 60 units | Single patient; factory calibrated; spirometer refs. 33509, 33511-14, 33518-22, 33527-29, 33530, 33532 and 33534 |
| Reusable turbine (flowmeter with metal mesh) | 910002 | Unit | Spirobank (incl. Spirobank II), Spirolab, Spirodoc and Minispir; with plastic or paper mouthpiece |
| Spirotel reusable turbine (flowmeter) | According to manufacturer’s catalogue | Unit | Exclusive to the Spirotel spirometer; plastic or paper mouthpiece |
| Disposable adult paper mouthpiece | 910300 | Individually packaged; box of 100 units | For reusable turbine; Ø 30 mm |
| Reusable adult plastic mouthpiece | According to manufacturer’s catalogue | Unit | For reusable turbine |
| Reusable paediatric plastic mouthpiece (white conical) | According to manufacturer’s catalogue | Unit | For paediatric purple reusable turbine |
| Disposable bacteria/virus filter | 33884 (GM33884) | Individually packaged; box of 100 units | Wide compatibility: MIR, Micromedical, Vitalograph, Ferraris (Koko legend) and Cardiette (Pneumos 300) |
| Nasal forceps | 910320-F | Unit | Recommended by the ATS/ERS guidelines for the spirometry manoeuvre |
| Thermal paper rolls for Spirolab printer | According to manufacturer’s catalogue | 10 rolls per box | Standard 112 mm thermal paper for the Spirolab printer |
3.2 Accessories
| Accessory | Manufacturer reference | Description |
|---|---|---|
| 3-litre calibration syringe | 919000 | Volumetric quality control (accuracy ±0.25% with adapters); periodic verification according to ATS/ERS; Spirolab, Spirodoc, Spirobank II and Minispir |
| Micro USB cable 1.8 m | 532367 (SKU 33523 / GM33523) | Connection of the spirometer to the PC for transferring tests to MIR Spiro PC software; Spirodoc refs. 33510/2/4, 33519-33520 and 33532-4 |
| Soft reusable adult sensor (oximetry) | According to manufacturer’s catalogue | Only for spirometers with oximetry option |
| Oximetry catheter extension cable (BCI, yellow arrow) | According to manufacturer’s catalogue | For spirometers with oximetry option; standard catheters compatible with BCI oximeters |
| Oximetry catheter extension cable (BCI, green arrow) | According to manufacturer’s catalogue | For spirometers with oximetry option; standard catheters compatible with BCI oximeters |
| Softtip® large oximetry catheter | Envitec RS-3222-12 (original BCI) | Reusable; for spirometers with oximetry option |
| Softtip® mediana oximetry catheter | Envitec RS-3222-12 (original BCI) | Reusable; for spirometers with oximetry option |
| Softtip® small oximetry catheter | Envitec RS-3222-12 (original BCI) | Reusable; for spirometers with oximetry option |
| Carrying case | According to manufacturer’s catalogue | For MIR spirometers, except Spirolab |
| Carrying bag for Spirolab | According to manufacturer’s catalogue | Specific transport for Spirolab spirometer |
| Carrying case and belt for Spirodoc | According to manufacturer’s catalogue | Protection and transport for Spirodoc |
| Charger for Spirolab | According to manufacturer’s catalogue | Power supply/recharging for Spirolab |
4. Equivalences and Cross-References
The manufacturer references MIR (Medical International Research) indicated in this datasheet have been cross-checked against internal technical documentation and the catalogue product sheets; the FlowMIR disposable turbine (910004) is the same sensor supplied under reference 33507 box of 60 units. There is no equivalence table validated by the manufacturer that cross-references MIR consumables with other brands as interchangeable 1:1, since the sensor coupling is specific to each device; references from other brands are offered only as comparable by category and must be validated before substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Observations |
|---|---|---|---|---|
| MIR | Disposable FlowMIR turbine with integrated cardboard mouthpiece | 910004 / 33507 (GM33507) | Exact reference equivalence (same manufacturer) | Dual SKU coding distributor / MIR code; dispenser box of 60 units |
| MIR | Reusable spirometry turbine | 910002 | Exact reference equivalence (same manufacturer) | Spirobank, Spirolab, Spirodoc and Minispir |
| MIR | Adult paper mouthpiece for reusable turbine | 910300 | Exact reference equivalence (same manufacturer) | Ø 30 mm; individually packaged; box of 100 units |
| MIR | 3 L calibration syringe | 919000 | Exact reference equivalence (same manufacturer) | Volumetric accuracy verification according to ATS/ERS |
| MIR | Disposable nasal forceps | 910320-F | Exact reference equivalence (same manufacturer) | Recommended by ATS/ERS for the manoeuvre |
| MIR | Micro USB cable for PC connection | 532367 / 33523 (GM33523) | Exact reference equivalence (same manufacturer) | Spirodoc 33510/2/4, 33519-33520 and 33532-4 |
| Italian brand | Disposable antibacterial filter with mouthpiece | 33884 (GM33884) | Comparable by category (not interchangeable 1:1) | Broad compatibility: MIR, Micromedical, Vitalograph, Ferraris and Cardiette |
| Vitalograph | Cardboard adult mouthpiece | 20201 | Comparable by category (not interchangeable 1:1) | Ext Ø ≈ 30.4 mm × 60 mm; box of 200 units; check fit to the device adapter |
| Sibelmed (SIBEL S.A.U.) | 3 L calibration syringe (S3000-3L) | 08290 | Comparable by category (not interchangeable 1:1) | Same volumetric quality control function; own connector of the Datospir range |
There is no equivalence table validated by the manufacturer that cross-references MIR consumables with other brands as interchangeable 1:1; consult with the technical department before using in a tender.
5. Selection tips and variants of interest
According to the spirometer model: the FlowMIR disposable turbine (910004) is compatible with series 33509, 33511-14, 33518-22, 33527-29, 33530, 33532 and 33534; for Spirolab, Spirodoc, Spirobank II and Minispir use the reusable turbine 910002; and remember that the Spirotel reusable turbine is exclusive to that device. According to patient rotation: in high-demand clinics, occupational medicine and screening campaigns, the disposable turbine with integrated mouthpiece (box of 60 units) reduces the cost per test and eliminates disinfection; with a correctly disinfected reusable circuit, the 910002 turbine with 910300 paper mouthpiece further reduces the cost of each examination. Additional protection: combine them with the 33884 antibacterial filter and the 910320-F nasal forceps. Quality control: periodically verify volumetric accuracy with the 3-litre syringe (919000) following ATS/ERS recommendations. Oximetry: choose the Softtip® catheter size (large, mediana or small) according to the patient and use the BCI extension cable with yellow or green arrow according to your device’s catheter. Consult our technical-commercial team for B2B volume conditions and hospital supply agreements.