We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Accessories and Consumables for MIR Spirometers – FlowMIR Turbines, Mouthpieces, Calibration Syringe, Oximetry, Thermal Paper and Transport

Price on request

Complete kit of accessories and consumables for MIR spirometers: FlowMIR disposable turbines (box of 10 and 60 units) and reusable, paper and plastic mouthpieces for adults and paediatrics, antibacterial filters, 3-litre calibration syringe, Softtip® oximetry sensors and catheters (original Envitec BCI), connection and extension cables, 112 mm thermal paper rolls for Spirolab, ATS/ERS nasal forceps and transport solutions (cases, bags and belts for Spirolab and Spirodoc). References verified with the manufacturer’s official codes for the Spirolab, Spirotel, Spirodoc, Spirobank, Minispir, Smart One and Smart One Oxi families.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ABM-ACCESORIOS-ESPIROMETRIA
Brand
MIR

Description

1. Commercial Introduction

Keep your spirometry station always operational with this section of accessories and consumables for MIR spirometers: from the disposable FlowMIR turbine for maximum patient-to-patient hygiene, to reusable turbines, paper and plastic mouthpieces, bacterial/viral filters, the 3-litre calibration syringe and thermal paper for the Spirolab printer. It also includes the optional oximetry block: reusable Softtip® sensors and catheters in three sizes, with extension cables compatible with BCI oximeters, and transport and power solutions (cases, bags, Spirodoc belt, charger and 1.8 m micro USB cable). A range designed for respiratory medicine services, primary care, occupational medicine and pulmonary function laboratories.

2. Technical explanation of the equipment and procedure

The MIR family spirometers (Spirolab, Spirotel, Spirodoc, Spirobank, Minispir, Smart One and Smart One Oxi) measure flow and volume using a low-inertia turbine sensor: the air that the patient inhales and exhales rotates the turbine and the device calculates the parameters (FVC, FEV1, PEF, FEF25-75%, MVV…) from the rotation speed. The disposable FlowMIR turbines are factory calibrated and require no further calibration: they are attached with their integrated cardboard mouthpiece, the test is performed and they are discarded, eliminating cross-contamination and reprocessing between patients. The reusable turbines (with metal mesh) are combined with a plastic or paper mouthpiece and allow a disinfected circuit with a lower cost per test. For the volumetric quality control recommended by the ATS/ERS guidelines, the 3-litre syringe allows periodic verification of the device’s accuracy; the nasal clip, also recommended by ATS/ERS, occludes nasal leakage during the manoeuvre. In devices with the oximetry option, the reusable Softtip® catheters (Envitec RS-3222-12, BCI original) record SpO2 and pulse rate simultaneously with spirometry.

3. Technical Specifications

3.1 Consumables

Consumable Manufacturer reference Presentation Use and compatibility
Disposable FlowMIR turbine with integrated cardboard mouthpiece 910004 (SKU 33507 / GM33507) Individual packaging; box of 10 units and dispenser box of 60 units Single patient; factory calibrated; spirometer refs. 33509, 33511-14, 33518-22, 33527-29, 33530, 33532 and 33534
Reusable turbine (flowmeter with metal mesh) 910002 Unit Spirobank (incl. Spirobank II), Spirolab, Spirodoc and Minispir; with plastic or paper mouthpiece
Spirotel reusable turbine (flowmeter) According to manufacturer’s catalogue Unit Exclusive to the Spirotel spirometer; plastic or paper mouthpiece
Disposable adult paper mouthpiece 910300 Individually packaged; box of 100 units For reusable turbine; Ø 30 mm
Reusable adult plastic mouthpiece According to manufacturer’s catalogue Unit For reusable turbine
Reusable paediatric plastic mouthpiece (white conical) According to manufacturer’s catalogue Unit For paediatric purple reusable turbine
Disposable bacteria/virus filter 33884 (GM33884) Individually packaged; box of 100 units Wide compatibility: MIR, Micromedical, Vitalograph, Ferraris (Koko legend) and Cardiette (Pneumos 300)
Nasal forceps 910320-F Unit Recommended by the ATS/ERS guidelines for the spirometry manoeuvre
Thermal paper rolls for Spirolab printer According to manufacturer’s catalogue 10 rolls per box Standard 112 mm thermal paper for the Spirolab printer

3.2 Accessories

Accessory Manufacturer reference Description
3-litre calibration syringe 919000 Volumetric quality control (accuracy ±0.25% with adapters); periodic verification according to ATS/ERS; Spirolab, Spirodoc, Spirobank II and Minispir
Micro USB cable 1.8 m 532367 (SKU 33523 / GM33523) Connection of the spirometer to the PC for transferring tests to MIR Spiro PC software; Spirodoc refs. 33510/2/4, 33519-33520 and 33532-4
Soft reusable adult sensor (oximetry) According to manufacturer’s catalogue Only for spirometers with oximetry option
Oximetry catheter extension cable (BCI, yellow arrow) According to manufacturer’s catalogue For spirometers with oximetry option; standard catheters compatible with BCI oximeters
Oximetry catheter extension cable (BCI, green arrow) According to manufacturer’s catalogue For spirometers with oximetry option; standard catheters compatible with BCI oximeters
Softtip® large oximetry catheter Envitec RS-3222-12 (original BCI) Reusable; for spirometers with oximetry option
Softtip® mediana oximetry catheter Envitec RS-3222-12 (original BCI) Reusable; for spirometers with oximetry option
Softtip® small oximetry catheter Envitec RS-3222-12 (original BCI) Reusable; for spirometers with oximetry option
Carrying case According to manufacturer’s catalogue For MIR spirometers, except Spirolab
Carrying bag for Spirolab According to manufacturer’s catalogue Specific transport for Spirolab spirometer
Carrying case and belt for Spirodoc According to manufacturer’s catalogue Protection and transport for Spirodoc
Charger for Spirolab According to manufacturer’s catalogue Power supply/recharging for Spirolab

4. Equivalences and Cross-References

The manufacturer references MIR (Medical International Research) indicated in this datasheet have been cross-checked against internal technical documentation and the catalogue product sheets; the FlowMIR disposable turbine (910004) is the same sensor supplied under reference 33507 box of 60 units. There is no equivalence table validated by the manufacturer that cross-references MIR consumables with other brands as interchangeable 1:1, since the sensor coupling is specific to each device; references from other brands are offered only as comparable by category and must be validated before substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Observations
MIR Disposable FlowMIR turbine with integrated cardboard mouthpiece 910004 / 33507 (GM33507) Exact reference equivalence (same manufacturer) Dual SKU coding distributor / MIR code; dispenser box of 60 units
MIR Reusable spirometry turbine 910002 Exact reference equivalence (same manufacturer) Spirobank, Spirolab, Spirodoc and Minispir
MIR Adult paper mouthpiece for reusable turbine 910300 Exact reference equivalence (same manufacturer) Ø 30 mm; individually packaged; box of 100 units
MIR 3 L calibration syringe 919000 Exact reference equivalence (same manufacturer) Volumetric accuracy verification according to ATS/ERS
MIR Disposable nasal forceps 910320-F Exact reference equivalence (same manufacturer) Recommended by ATS/ERS for the manoeuvre
MIR Micro USB cable for PC connection 532367 / 33523 (GM33523) Exact reference equivalence (same manufacturer) Spirodoc 33510/2/4, 33519-33520 and 33532-4
Italian brand Disposable antibacterial filter with mouthpiece 33884 (GM33884) Comparable by category (not interchangeable 1:1) Broad compatibility: MIR, Micromedical, Vitalograph, Ferraris and Cardiette
Vitalograph Cardboard adult mouthpiece 20201 Comparable by category (not interchangeable 1:1) Ext Ø ≈ 30.4 mm × 60 mm; box of 200 units; check fit to the device adapter
Sibelmed (SIBEL S.A.U.) 3 L calibration syringe (S3000-3L) 08290 Comparable by category (not interchangeable 1:1) Same volumetric quality control function; own connector of the Datospir range

There is no equivalence table validated by the manufacturer that cross-references MIR consumables with other brands as interchangeable 1:1; consult with the technical department before using in a tender.

5. Selection tips and variants of interest

According to the spirometer model: the FlowMIR disposable turbine (910004) is compatible with series 33509, 33511-14, 33518-22, 33527-29, 33530, 33532 and 33534; for Spirolab, Spirodoc, Spirobank II and Minispir use the reusable turbine 910002; and remember that the Spirotel reusable turbine is exclusive to that device. According to patient rotation: in high-demand clinics, occupational medicine and screening campaigns, the disposable turbine with integrated mouthpiece (box of 60 units) reduces the cost per test and eliminates disinfection; with a correctly disinfected reusable circuit, the 910002 turbine with 910300 paper mouthpiece further reduces the cost of each examination. Additional protection: combine them with the 33884 antibacterial filter and the 910320-F nasal forceps. Quality control: periodically verify volumetric accuracy with the 3-litre syringe (919000) following ATS/ERS recommendations. Oximetry: choose the Softtip® catheter size (large, mediana or small) according to the patient and use the BCI extension cable with yellow or green arrow according to your device’s catheter. Consult our technical-commercial team for B2B volume conditions and hospital supply agreements.

Additional information

Brand

MIR

Product type

Accessories and consumables for MIR spirometers (ABM-ACCESORIOS-ESPIROMETRIA family)

Compatible families

Spirolab, Spirotel, Spirodoc, Spirobank (incl. Spirobank II), Minispir, Smart One, Smart One Oxi

Sensor technology

Low-inertia turbine (FlowMIR); direct flow measurement by rotation; factory calibrated

Disposable turbine

910004 (SKU 33507); individually packaged; box of 10 units and dispenser box of 60 units

Reusable turbine

910002; metal mesh; with plastic or paper mouthpiece

Nozzles

Disposable adult paper (910300, Ø 30 mm); reusable adult and paediatric plastic (white conical)

Filter

Disposable bacteria/virus filter (33884); individually packaged; box of 100 units

Calibration

Turbines: no calibration required; 3 L syringe (919000) for ATS/ERS verification

Oximetry

Reusable Softtip® catheters (Envitec RS-3222-12, BCI original) in large, mediana and small sizes; BCI extension cables with yellow and green arrow; soft reusable adult sensor

Thermal paper

Standard 112 mm rolls for Spirolab printer; 10 rolls per box

Connectivity

Micro USB cable 1.8 m (MIR 532367 / SKU 33523) for transferring tests to MIR Spiro PC software

Transport

Case (except Spirolab), Spirolab bag, Spirodoc box and belt, Spirolab charger

Regulatory standard

ATS/ERS recommendations; nasal clip recommended by ATS/ERS

Reviews

There are no reviews yet.

Be the first to review “Accessories and Consumables for MIR Spirometers – FlowMIR Turbines, Mouthpieces, Calibration Syringe, Oximetry, Thermal Paper and Transport”

Your email address will not be published. Required fields are marked *