Description
1. Commercial Introduction
The oxygen flowmeter with AFNOR connection is the bedside component for regulating and controlling the supply of medicinal oxygen in care areas: resuscitation bays, emergency departments, ICUs, hospital wards, pulmonology services and examination rooms. Its flow range of 0 to 15 l/min offers excellent reading resolution for low- and medium-flow oxygen therapy, while its AFNOR connection ensures a direct and airtight coupling to wall outlets and terminal units of the medical gas network. Manufactured in Italy, for oxygen therapy and medical gases, it is the robust and reliable solution for professional oxygen supply.
2. Technical explanation of the equipment
The flowmeter is a measuring and regulating device that is placed between the medical gas network outlet and the patient administration device. In this model, oxygen from the terminal unit enters through the AFNOR connection and rises up the graduated burette, where a float indicates in real time the flow rate being supplied (expressed in litres per minute). The flow rate is precisely adjusted using the knob on the front of the equipment, allowing the professional to select the therapeutic flow appropriate for each patient. The lateral 9/16″ outlet allows connection of a humidifier (disposable or reusable) or, optionally, a hose connector when humidification is not required. A filter located at the inlet of the burette protects both the patient and the flowmeter itself from possible impurities in the circuit, and the nickel-plated brass body ensures durability and resistance in continuous care use.
3. Technical Specifications
| Characteristic | Specification |
| Manufacturer | Boscarol |
| Product type | Flowmeter for oxygen supply |
| Flow rate range | 0-15 l/min (litres per minute) |
| Flow rate indication | In real time via graduated scale on the burette |
| Body material | Nickel-plated brass |
| Inlet connection | AFNOR connection for direct connection to the terminal unit |
| Outlet connection | 9/16″ for humidifier or hose connector (optional) |
| Protective filter | Located at the inlet of the burette; protects the patient and the flowmeter |
| Flow rate regulation | Adjustment knob located on the front of the device |
| Compatibility | Disposable or reusable humidifiers |
| Manufacture | Made in Italy |
| Classification | Medical device class IIa in accordance with Directive 93/42/EEC |
Available references:
| Manufacturer reference | SKU Cahnos |
| OXI0587 | BRLOXI0587 |
4. Equivalences and Cross-References
This product corresponds to the manufacturer’s official reference. OXI0587, marketed in Cahnos under the SKU BRLOXI0587, without transcriptions or modifications; always keep both codes intact when placing an order or tender. Within the catalogue itself, this reference has its higher-flow variant with AFNOR connection (0-30 l/min) and the UNI connection versions of the same family (0-15 l/min and 0-30 l/min), which share a nickel-plated brass body, 9/16″ outlet and filter in the burette, differing only in the connection system to the outlet and in the flow range. No manufacturer-validated 1:1 equivalence table cross-referencing this reference with specific codes from other manufacturers has been found in reliable sources; the AFNOR standard, the flow range and the type of outlet connection must always be verified before considering any substitution in a tender. Consult our technical-commercial department to validate equivalent alternatives.
5. Selection tips and variants of interest
Always verify the connection standard of your medical gas network: this reference uses an AFNOR outlet, so it is ideal for installations with French/AFNOR standard terminal units. If your network works with UNI connection, select the UNI variant of the same flowmeter family. Check the required flow range: the 0-15 l/min range offers greater resolution and reading accuracy for low-flow oxygen therapy; if you require high flow rates, the 0-30 l/min version with AFNOR connection is the natural alternative. Complete the circuit with the oxygen therapy humidifier with 9/16″ inlet (autoclavable bottle and lid) or, if administration is dry, with the 9/16″ flowmeter hose connector that replaces the humidifier. For distribution and fittings, the range includes oxygen hose conforming to ISO 5359 and fittings with crimped fixing. For large orders you can request a quote: contact our technical-commercial team for conditions, availability and advice on complete oxygen therapy equipment.