Description
Introduction
The Cervical Cerclage Kit, Cervix-Set type (Ref. AMPTN50) is the reference surgical solution for the treatment of cervical incompetence during pregnancy. It is presented as a complete, sterile, single-use kit that reinforces the cervix and prevents its premature opening, reducing the risk of preterm birth and gestational loss in the second trimester. A reliable and practical option for obstetrics departments, maternal-fetal medicine units and gynaecology operating theatres, also available in a 65 mm version (Ref. AMPTN65).
Technical explanation of the equipment
Cervical cerclage is a surgical procedure that involves placing a reinforcing suture around the cervix to keep it closed during pregnancy. It is indicated in women with a history of preterm birth, cervical incompetence, or when ultrasound imaging shows a short or dilated cervix. This kit uses a non-absorbable braided multifilament polyester tape with high tensile strength, which distributes pressure over a wide surface and minimises the risk of cutting or tearing cervical tissue. The tape is armed at both ends with a 1/2 circle needle with a blunt 50 mm point, allowing the surgeon to encircle the cervix precisely, displacing tissues without puncturing vascular structures. The configuration with blunt needles at both ends corresponds to the Shirodkar cervical ligation technique and the transabdominal or laparoscopic approach, being especially useful when the cervix is very short or a previous transvaginal cerclage has failed. The procedure can be performed vaginally (the most common) or abdominally, and the sutures are removed near the end of pregnancy or at the onset of labour.
Technical specifications
The design and dimensional characteristics of the kit ensure predictable and safe handling during the cerclage procedure:
| Parameter | Specification |
|---|---|
| Reference | AMPTN50 |
| Product type | Cervical cerclage kit, Cervix-Set type |
| Tape | Non-absorbable braided multifilament polyester |
| Tape measurements | 50 cm length x 5 mm width |
| Needles | Double armed needle (one at each end) |
| Needle curvature | 1/2 circle |
| Needle tip | Blunt (non-traumatic) |
| Needle length | 50 mm |
| Needle material | Surgical stainless steel |
| Absorption | Non-absorbable |
| Main indication | Cervical incompetence during pregnancy |
| Presentation | Sterile single-use kit |
Compatible cerclage techniques:
- Transvaginal cerclage (Shirodkar technique): dissection and placement of the tape at the level of the internal cervical os.
- Transabdominal cerclage by laparoscopy: minimally invasive access for short, conised cervices or after failure of the vaginal approach.
- Rescue cerclage in pregnancies with a shortened cervix or premature dilatation detected by ultrasound imaging.
Equivalences and cross-references
The AMPTN50 kit reproduces the classic clinical configuration of internationally referenced cervical cerclage sets. Due to its design of 5 mm polyester tape with double blunt-point needles, it is functionally equivalent to the Cervix Set from B. Braun (Shirodkar technique), which uses polyester tape or Dagrofil® suture armed at each end with a blunt-point needle, and to the MERSILENE® tape from Ethicon (reference RS21: white polyester strip 5 mm x 12″ with blunt BP-1 needles of 65 mm, 1/2 circle, double armed). These equivalences facilitate product approval in hospital purchasing protocols and its direct substitution in purchasing centres and supply tenders. In the Cahnos catalogue, the twin version with a 65 mm needle (Ref. AMPTN65) completes the Cervix-Set range.
Selection tips and variants of interest
Select the needle length according to the approach: the 50 mm version (AMPTN50) is better suited to approaches requiring a shorter, more manoeuvrable needle, while the 65 mm version (AMPTN65) is ideal for transabdominal and laparoscopic cerclage and for larger cervices. Always verify the planned surgical technique (Shirodkar, McDonald or Wurm-Hefner) to choose the appropriate needle configuration — blunt point for Shirodkar with tape and cutting point for thread techniques. To complete the procedure, it is recommended to have supporting disposable gynaecological instruments, such as Pozzi forceps for traction and fixation of the cervix, specula and needle holders. Confirm stock availability and sterility conditions before the intervention.





Reviews
There are no reviews yet.