Pre-gelled sensor pad electrodes for body composition analysers (BIA) (ref. 27319). Designed for body fat analysis and electrotherapy applications, they incorporate a high-grip solid adhesive gel that maintains its adhesion and allows repositioning the electrode on the same patient. Their highly flexible material facilitates placement and adaptation to the equipment platform, while the internal silicone/PVC coating allows them to be comfortably repositioned after each use. Latex-free product, supplied in a box of 100 units. Class I medical device. For large orders you can request a quote.

Sales unit: caja de 100
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM27319

Description

1. Commercial Introduction

Keep your body composition analyser always operational with the pre-gelled electrode sensor pad (ref. 27319), the replacement consumable specially developed for body fat analysis using bioelectrical impedance (BIA). It is a single-use electrode, ready to apply, with features designed for daily practice: maximum flexibility, stable adhesion and easy repositioning to speed up measurements in nutrition and dietetics clinics, pharmacies, sports centres and weight management programmes.

2. Technical Explanation

These pre-gelled electrodes have been designed based on FIAB technology for electrotherapy applications and adapted for body composition analysis. Their highly flexible material allows easy and precise placement on the analyser surface, ensuring homogeneous contact that improves the reliability of bioelectrical impedance measurement.

The electrode incorporates a solid conductive gel with excellent adhesive properties that maintains its grip during the test and allows repositioning the electrode on the same patient if the contact point needs adjusting. Furthermore, thanks to the internal silicone/PVC coating, the electrodes can be comfortably repositioned after use without losing adhesion. The entire assembly is latex-free, which minimises the risk of allergic reactions.

3. Technical Specifications

Main features of the pre-gelled electrode sensor pad for body fat analyser:

Parameter Specification
Product type Sensor pad / pre-gelled electrodes for body composition analyser
Application Body fat analysis (bioelectrical impedance, BIA) and electrotherapy
Gel Solid conductive gel, adhesive and repositionable
Material Highly flexible, with internal silicone/PVC coating
Repositioning Yes, on the same patient
Latex Latex-free

Product data

Manufacturer GIMA
Manufacturer reference 27319
Sales unit box of 100 pcs (box of 100 units)
Device type Medical device (medical device)
Device class I
CND N010299
GMDN 61020
EAN 8033695722010

4. Equivalences and Cross-References

This sensor pad corresponds to reference 27319 (SKU Cahnos GM27319), manufactured using FIAB pre-gelled electrode technology. No equivalence table validated by the manufacturer authorising direct 1:1 substitution with codes from other manufacturers has been found in reliable sources, so no third-party equivalent references are declared.

Within the same catalogue distributed by Cahnos, this consumable is naturally related to the body composition analysers in the range, such as the body composition scale with 8 sensors (ref. 27293) and the 6-parameter BIA analyser (ref. 27291), with which it is compatible by application. Before any substitution or tender, consult the technical-commercial department of Cahnos to validate compatibility field by field.

5. Selection tips and variants of interest

Verify your analyser model: these sensor pad type electrodes are intended for body fat analysis equipment using bioelectrical impedance (BIA); confirm the electrode fit and the contact area of your platform before replenishing the consumable.

Preparation and placement: clean and dry the surface of the electrode and the analyser before measurement; thanks to the repositionable gel, if the first contact is not optimal, you can reposition the electrode on the same patient without losing adhesion.

Stock management and replenishment: as this is a single-use consumable supplied in a box of 100 units, we recommend calculating the monthly turnover of your service (clinics, sports centres or weight management programmes) and maintaining a minimum stock to avoid interrupting measurements. Keep the boxes closed in a dry, cool place.

Latex-free product: suitable for patients with latex allergy or sensitivity. For institutional orders, tenders or volume supply conditions, contact the technical-commercial department of Cahnos. For large orders you can request a quote.

Additional information

Manufacturer reference

27319

Product type

Sensor pad / pre-gelled electrodes for body composition analyser

Application

Body fat analysis (bioelectrical impedance, BIA) and electrotherapy

Gel

Adhesive and repositionable solid conductive gel

Material

Highly flexible, with internal silicone/PVC coating

Repositionable

Yes, on the same patient

Presentation

Box of 100 units

Device type

Medical device (Medical device)

CND code

N010299

GMDN code

61020

EAN

8033695722010

Presentacion

Box of 100

Tipo dispositivo

Medical device

Clase sanitaria

I

Latex

Latex-free

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Pre-gelled Electrode Sensor Pad for Body Composition Analyser (BIA) – Repositionable, Latex-free, Box of 100 units (Ref. 27319)”

Your email address will not be published. Required fields are marked *